Anisotropic Diffusion Filter With Memory Based on Speckle Statistics for Ultrasound Images

Ultrasound (US) imaging exhibits considerable difficulties for medical visual inspection and for development of automatic analysis methods due to speckle, which negatively affects the perception of tissue boundaries and the performance of automatic segmentation methods. With the aim of alleviating the effect of speckle, many filtering techniques are usually considered as a preprocessing step prior to automatic analysis methods or visual inspection. Most of the state-of-the-art filters try to reduce the speckle effect without considering its relevance for the characterization of tissue nature. However, the speckle phenomenon is the inherent response of echo signals in tissues and can provide important features for clinical purposes. This loss of information is even magnified due to the iterative process of some speckle filters, e.g., diffusion filters, which tend to produce over-filtering because of the progressive loss of relevant information for diagnostic purposes during the diffusion process. In this paper, we propose an anisotropic diffusion filter with a probabilistic-driven memory mechanism to overcome the over-filtering problem by following a tissue selective philosophy. In particular, we formulate the memory mechanism as a delay differential equation for the diffusion tensor whose behavior depends on the statistics of the tissues, by accelerating the diffusion process in meaningless regions and including the memory effect in regions where relevant details should be preserved. Results both in synthetic and real US images support the inclusion of the probabilistic memory mechanism for maintaining clinical relevant structures, which are removed by the state-of-the-art filters.

[1]  Jitendra Malik,et al.  Scale-Space and Edge Detection Using Anisotropic Diffusion , 1990, IEEE Trans. Pattern Anal. Mach. Intell..

[2]  R. F. Wagner,et al.  Statistics of Speckle in Ultrasound B-Scans , 1983, IEEE Transactions on Sonics and Ultrasonics.

[3]  K. Boone,et al.  Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study , 1996, Medical and Biological Engineering and Computing.

[4]  Max A. Viergever,et al.  Efficient and reliable schemes for nonlinear diffusion filtering , 1998, IEEE Trans. Image Process..

[5]  A. Sarti,et al.  Nonlinear multiscale analysis of three-dimensional echocardiographic sequences , 1999, IEEE Transactions on Medical Imaging.

[6]  J. Greenleaf,et al.  Ultrasound echo envelope analysis using a homodyned K distribution signal model. , 1994, Ultrasonic imaging.

[7]  Eero P. Simoncelli,et al.  Image quality assessment: from error visibility to structural similarity , 2004, IEEE Transactions on Image Processing.

[8]  Santiago Aja-Fernández,et al.  On the influence of interpolation on probabilistic models for ultrasonic images , 2010, 2010 IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[9]  Andriy Myronenko,et al.  Maximum Likelihood Motion Estimation in 3D Echocardiography through Non-rigid Registration in Spherical Coordinates , 2009, FIMH.

[10]  Alejandro F. Frangi,et al.  Probabilistic-Driven Oriented Speckle Reducing Anisotropic Diffusion with Application to Cardiac Ultrasonic Images , 2010, MICCAI.

[11]  Marcos Martín-Fernández,et al.  An approach for contour detection of human kidneys from ultrasound images using Markov random fields and active contours , 2005, Medical Image Anal..

[12]  T. Marwick Measurement of strain and strain rate by echocardiography: ready for prime time? , 2006, Journal of the American College of Cardiology.

[13]  Olivier Basset,et al.  Segmentation of ultrasound images--multiresolution 2D and 3D algorithm based on global and local statistics , 2003, Pattern Recognit. Lett..

[14]  Charles Perreault,et al.  Speckle Simulation Based on B-Mode Echographic Image Acquisition Model , 2007, Fourth Canadian Conference on Computer and Robot Vision (CRV '07).

[15]  Victor S. Frost,et al.  A Model for Radar Images and Its Application to Adaptive Digital Filtering of Multiplicative Noise , 1982, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[16]  Lars Kai Hansen,et al.  Quantitative analysis of ultrasound B-mode images of carotid atherosclerotic plaque: correlation with visual classification and histological examination , 1998, IEEE Transactions on Medical Imaging.

[17]  Marcos Martin-Fernandez,et al.  Gamma mixture classifier for plaque detection in intravascular ultrasonic images , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[18]  Milan Sonka,et al.  Automatic segmentation of echocardiographic sequences by active appearance motion models , 2002, IEEE Transactions on Medical Imaging.

[19]  Joachim Weickert,et al.  Anisotropic diffusion in image processing , 1996 .

[20]  Jean Meunier,et al.  Segmentation in Ultrasonic B-Mode Images of Healthy Carotid Arteries Using Mixtures of Nakagami Distributions and Stochastic Optimization , 2009, IEEE Transactions on Medical Imaging.

[21]  G.E. Sleefe,et al.  Tissue characterization based on scatterer number density estimation , 1988, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[22]  J. Thijssen,et al.  Texture in tissue echograms. Speckle or information? , 1990, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[23]  Santiago Aja-Fernández,et al.  On the estimation of the coefficient of variation for anisotropic diffusion speckle filtering , 2006, IEEE Transactions on Image Processing.

[24]  P.M. Shankar,et al.  A compound scattering pdf for the ultrasonic echo envelope and its relationship to K and Nakagami distributions , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[25]  Georges-Henri Cottet,et al.  A Volterra type model for image processing , 1998, IEEE Trans. Image Process..

[26]  Alexander A. Sawchuk,et al.  Adaptive Noise Smoothing Filter for Images with Signal-Dependent Noise , 1985, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[27]  E. Nezry,et al.  Maximum A Posteriori Speckle Filtering And First Order Texture Models In Sar Images , 1990, 10th Annual International Symposium on Geoscience and Remote Sensing.

[28]  Jean-Michel Morel,et al.  A non-local algorithm for image denoising , 2005, 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'05).

[29]  P. Mohana Shankar,et al.  A general statistical model for ultrasonic backscattering from tissues , 2000, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[30]  Pierrick Coupé,et al.  Nonlocal Means-Based Speckle Filtering for Ultrasound Images , 2009, IEEE Transactions on Image Processing.

[31]  Gonzalo Vegas-Sánchez-Ferrero,et al.  A Gamma Mixture Model for IVUS Imaging , 2014 .

[32]  Carl-Fredrik Westin,et al.  Oriented Speckle Reducing Anisotropic Diffusion , 2007, IEEE Transactions on Image Processing.

[33]  Robert F Wagner,et al.  Unified Approach to the Detection and Classification of Speckle Texture in Diagnostic Ultrasound. , 1986, Optical engineering.

[34]  Charles Elkan,et al.  Expectation Maximization Algorithm , 2010, Encyclopedia of Machine Learning.

[35]  J. Arendt Paper presented at the 10th Nordic-Baltic Conference on Biomedical Imaging: Field: A Program for Simulating Ultrasound Systems , 1996 .

[36]  Scott T. Acton,et al.  Ultrasound Despeckling Using an Adaptive Window Stochastic Approach , 2006, 2006 International Conference on Image Processing.

[37]  Scott T. Acton,et al.  Speckle reducing anisotropic diffusion , 2002, IEEE Trans. Image Process..

[38]  Jong-Sen Lee,et al.  Digital Image Enhancement and Noise Filtering by Use of Local Statistics , 1980, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[39]  Petia Radeva,et al.  Rayleigh Mixture Model for Plaque Characterization in Intravascular Ultrasound , 2011, IEEE Transactions on Biomedical Engineering.

[40]  J. Alison Noble,et al.  Ultrasound image segmentation: a survey , 2006, IEEE Transactions on Medical Imaging.

[41]  J. Goodman Some fundamental properties of speckle , 1976 .