Accurate modeling of a DOI capable small animal PET scanner using GATE.

In this work we developed a Monte Carlo (MC) model of the Sedecal Argus pre-clinical PET scanner, using GATE (Geant4 Application for Tomographic Emission). This is a dual-ring scanner which features DOI compensation by means of two layers of detector crystals (LYSO and GSO). Geometry of detectors and sources, pulses readout and selection of coincidence events were modeled with GATE, while a separate code was developed in order to emulate the processing of digitized data (for example, customized time windows and data flow saturation), the final binning of the lines of response and to reproduce the data output format of the scanner's acquisition software. Validation of the model was performed by modeling several phantoms used in experimental measurements, in order to compare the results of the simulations. Spatial resolution, sensitivity, scatter fraction, count rates and NECR were tested. Moreover, the NEMA NU-4 phantom was modeled in order to check for the image quality yielded by the model. Noise, contrast of cold and hot regions and recovery coefficient were calculated and compared using images of the NEMA phantom acquired with our scanner. The energy spectrum of coincidence events due to the small amount of (176)Lu in LYSO crystals, which was suitably included in our model, was also compared with experimental measurements. Spatial resolution, sensitivity and scatter fraction showed an agreement within 7%. Comparison of the count rates curves resulted satisfactory, being the values within the uncertainties, in the range of activities practically used in research scans. Analysis of the NEMA phantom images also showed a good agreement between simulated and acquired data, within 9% for all the tested parameters. This work shows that basic MC modeling of this kind of system is possible using GATE as a base platform; extension through suitably written customized code allows for an adequate level of accuracy in the results. Our careful validation against experimental data confirms that the developed simulation setup is a useful tool for a wide range of research applications.

[1]  V. Spanoudaki,et al.  Evaluation of different random estimation methods for the MADPET-II small animal PET scanner using GATE , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[2]  Dale L Bailey,et al.  The use of molecular sieves to produce point sources of radioactivity. , 2004, Physics in medicine and biology.

[3]  S. Incerti,et al.  Geant4 developments and applications , 2006, IEEE Transactions on Nuclear Science.

[4]  Jurgen Seidel,et al.  Performance evaluation of the GE healthcare eXplore VISTA dual-ring small-animal PET scanner. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[5]  Rik Van de Walle,et al.  Monte Carlo simulation in PET and SPECT instrumentation using GATE , 2004 .

[6]  Brian E. Zimmerman,et al.  Development of a Traceable Calibration Methodology for Solid 68Ge/68Ga Sources Used as a Calibration Surrogate for 18F in Radionuclide Activity Calibrators , 2010, Journal of Nuclear Medicine.

[7]  V. Ambrosini,et al.  Molecular Imaging of Neuroblastoma Progression in TH-MYCN Transgenic Mice , 2013, Molecular Imaging and Biology.

[8]  H. Malcolm Hudson,et al.  Accelerated image reconstruction using ordered subsets of projection data , 1994, IEEE Trans. Medical Imaging.

[9]  Irène Buvat,et al.  Evolution of the GATE project: new results and developments , 2007 .

[10]  Michel Defrise,et al.  Exact and approximate rebinning algorithms for 3-D PET data , 1997, IEEE Transactions on Medical Imaging.

[11]  S Stute,et al.  GATE V6: a major enhancement of the GATE simulation platform enabling modelling of CT and radiotherapy , 2011, Physics in medicine and biology.

[12]  H Zaidi,et al.  Relevance of accurate Monte Carlo modeling in nuclear medical imaging. , 1999, Medical physics.

[13]  David Guez,et al.  Modeling electronic processing in GATE , 2006 .

[14]  Roger Lecomte,et al.  NEMA NU 4-2008 Comparison of Preclinical PET Imaging Systems , 2012, The Journal of Nuclear Medicine.

[15]  Irène Buvat,et al.  Monte Carlo simulations in emission tomography and GATE: An overview , 2006 .

[16]  Mario Marengo,et al.  RECONSTRUCTION OF DYNAMIC PET IMAGES USING ACCURATE SYSTEM POINT SPREAD FUNCTION MODELING: EFFECTS ON PARAMETRIC IMAGES , 2010 .

[17]  C Lartizien,et al.  GATE: a simulation toolkit for PET and SPECT. , 2004, Physics in medicine and biology.

[18]  Mario Marengo,et al.  Performance evaluation of a small animal PET scanner. Spatial resolution characterization using 18F and 11C , 2007 .

[19]  Christoph Hoeschen,et al.  A Compartmental Model for Biokinetics and Dosimetry of 18F-Choline in Prostate Cancer Patients , 2012, The Journal of Nuclear Medicine.

[20]  T. Koi,et al.  Geant 4 Developments and Applications , 2013 .

[21]  R D Badawi,et al.  Randoms variance reduction in 3D PET. , 1999, Physics in medicine and biology.

[22]  F. Rademakers,et al.  ROOT — An object oriented data analysis framework , 1997 .