Validation of target volume and position in respiratory gated CT planning and treatment.

The capability of a commercial respiratory gating system based on video tracking of reflective markers to reduce motion-induced CT planning and treatment errors was evaluated. Spherical plastic shells (2.8-82 cm3), simulating the gross target volume (GTV), were placed in a water-filled body phantom that was moved sinusoidally along the longitudinal axis of the CT scanner and the accelerator for +/- 1 cm at 15-30 cycle/min. During gated CT imaging, the x-ray exposure was initiated by the gating system shortly before the end of expiration (so that the imaging time would be centered at the end of expiration); it was terminated by the scanner after completion of each slice. In nongated CT images, the target appeared distorted and often broken up. GTVs volume errors ranged 16%-110% in axial scans, and 7%-36% in spiral scans. In gated CT images, the spheres appeared 3 and 5 mm longer than their actual diameters (volume errors 2%-16%), at the respective respiration rates of 15 and 20 cycles/min. At 30 cycles/min the target appeared 1 cm longer, and volume error ranged 25%-53%. During treatment, gating kept the beam on for a duration equal to the CT acquisition time of 1 s/slice. The difference in positional errors between gated CT and portal films was 1 mm, regardless the size of residual motion errors. Because of the potential of suboptimal placement of the gating window between CT imaging and treatment, an extra 1.5-2.5 mm safety margin can be added regardless of the size of residual motion error. For respiratory rates > or = 30 cycles/min, the effectiveness of gating is limited by large residual motion in the 1 s CT acquisition time.

[1]  D A Jaffray,et al.  Active breathing control (ABC) for Hodgkin's disease: reduction in normal tissue irradiation with deep inspiration and implications for treatment. , 2000, International journal of radiation oncology, biology, physics.

[2]  C. Ramsey,et al.  A comparison of beam characteristics for gated and nongated clinical x-ray beams. , 1999, Medical physics.

[3]  S Minohara,et al.  Respiratory gated irradiation system for heavy-ion radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[4]  G J Kutcher,et al.  Deep inspiration breath-hold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation. , 1999, International journal of radiation oncology, biology, physics.

[5]  H. Mostafavi,et al.  Breathing-synchronized radiotherapy program at the University of California Davis Cancer Center. , 2000, Medical physics.

[6]  J. Wong,et al.  The use of active breathing control (ABC) to reduce margin for breathing motion. , 1999, International journal of radiation oncology, biology, physics.

[7]  C C Ling,et al.  The deep inspiration breath-hold technique in the treatment of inoperable non-small-cell lung cancer. , 2000, International journal of radiation oncology, biology, physics.

[8]  C. Ling,et al.  Technical aspects of the deep inspiration breath-hold technique in the treatment of thoracic cancer. , 2000, International journal of radiation oncology, biology, physics.

[9]  Gikas S. Mageras,et al.  Fluoroscopic evaluation of diaphragmatic motion reduction with a respiratory gated radiotherapy system , 2001, Journal of applied clinical medical physics.

[10]  H. Kubo,et al.  Respiration gated radiotherapy treatment: a technical study. , 1996, Physics in medicine and biology.

[11]  M. Kris,et al.  Promising survival with three-dimensional conformal radiation therapy for non-small cell lung cancer. , 1997, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[12]  K. Ekstrand,et al.  Pitfalls in the use of high energy X rays to treat tumors in the lung. , 1990, International journal of radiation oncology, biology, physics.

[13]  C. Ling,et al.  Evaluation of respiratory movement during gated radiotherapy using film and electronic portal imaging. , 2002, International journal of radiation oncology, biology, physics.

[14]  M. Martel,et al.  Dose escalation for non-small cell lung cancer using conformal radiation therapy. , 1997, International journal of radiation oncology, biology, physics.

[15]  H Shirato,et al.  Impact of respiratory movement on the computed tomographic images of small lung tumors in three-dimensional (3D) radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[16]  K. Lam,et al.  Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing. , 1996, International journal of radiation oncology, biology, physics.

[17]  K. Ohara,et al.  Irradiation synchronized with respiration gate. , 1989, International journal of radiation oncology, biology, physics.

[18]  R Mohan,et al.  Determining parameters for respiration-gated radiotherapy. , 2001, Medical physics.

[19]  T Kozuka,et al.  Lung cancer: intermittent irradiation synchronized with respiratory motion--results of a pilot study. , 1998, Radiology.