Failure mode of suture anchors as a function of insertion depth.

BACKGROUND Surgeons can control not only the angle but also the depth of suture anchor placement during arthroscopic rotator cuff repair, although the tendency may be to place suture anchors on the deep side to avoid damage from prominent anchor eyelets. However, little information is available regarding possible effects of suture anchor depth on construct failure mechanisms. HYPOTHESIS Anchor depth affects the mode of suture failure with physiologically relevant cyclic loads. STUDY DESIGN Controlled laboratory study. METHODS Metallic screw-in suture anchors loaded with No. 2 braided polyester sutures were inserted into the bovine infra-spinatus footprint with the eyelet proud, standard, or deep. Sutures were hand tied to create a closed loop. Constructs were cyclically loaded from 10 to 90 N and, if still intact at 500 cycles, taken to ultimate failure (maximum load). RESULTS When clinical failure was defined as greater than 3-mm construct elongation, anchors placed with the eyelet deep experienced statistically earlier clinical failure via cutting of the suture through the bone (P < .02). However, anchors placed at this level did not experience catastrophic failure during cyclic loading. The standard and proud anchors experienced 3 mm of elongation at a greater number of cycles, but the suture material degraded at the anchor eyelet, and a majority of these constructs broke during cyclic physiologic loading. At failure testing, the deep anchors had a significantly increased failure load (164 N) compared to standard (133 N) (P < .04) and proud (113 N) anchors (P < .005). CONCLUSION Varying the depth of suture anchor insertion changes the mechanical properties and mode of failure of suture anchor constructs. CLINICAL RELEVANCE Surgeons should be aware of the effects of suture anchor depth and abrasive eyelet wear on construct failure during arthroscopic rotator cuff repair.

[1]  C. Baker,et al.  Arthroscopically assisted rotator cuff repair: correlation of functional results with integrity of the cuff. , 1994, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[2]  V. Goradia,et al.  Cyclic loading of rotator cuff repairs: A comparison of bioabsorbable tacks with metal suture anchors and transosseous sutures. , 2001, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[3]  W D Cannon,et al.  Elongation of Arthroscopically Tied Knots , 1997, The American journal of sports medicine.

[4]  D. T. Harryman,et al.  Optimizing arthroscopic knots using braided or monofilament suture. , 1998, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[5]  S. Burkhart The deadman theory of suture anchors: observations along a south Texas fence line. , 1995, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[6]  P. Cawley,et al.  Suture anchor failure strength--an in vivo study. , 1993, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[7]  A. Amis,et al.  A Biomechanical Evaluation Of Suture Anchors In Repair Of The Rotator Cuff , 1997 .

[8]  Christian Gerber,et al.  Failure of suture material at suture anchor eyelets. , 2002, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[9]  D. Kohn,et al.  Fatigue Testing of Suture Anchors , 2002, The American journal of sports medicine.

[10]  L. Snyder-Mackler,et al.  Failure properties of suture anchors in the glenoid and the effects of cortical thickness. , 1998, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[11]  M. Wirth,et al.  Cyclic loading of anchor-based rotator cuff repairs: confirmation of the tension overload phenomenon and comparison of suture anchor fixation with transosseous fixation. , 1997, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[12]  S S Burkhart,et al.  Knot security in simple sliding knots and its relationship to rotator cuff repair: how secure must the knot be? , 2000, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[13]  M. Herbert,et al.  Suture anchors--update 1999. , 1999, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[14]  F A Matsen,et al.  Repairs of the rotator cuff. Correlation of functional results with integrity of the cuff. , 1991, The Journal of bone and joint surgery. American volume.