Review of cooling technologies for computer products

This paper provides a broad review of the cooling technologies for computer products from desktop computers to large servers. For many years cooling technology has played a key role in enabling and facilitating the packaging and performance improvements in each new generation of computers. The role of internal and external thermal resistance in module level cooling is discussed in terms of heat removal from chips and module and examples are cited. The use of air-cooled heat sinks and liquid-cooled cold plates to improve module cooling is addressed. Immersion cooling as a scheme to accommodate high heat flux at the chip level is also discussed. Cooling at the system level is discussed in terms of air, hybrid, liquid, and refrigeration-cooled systems. The growing problem of data center thermal management is also considered. The paper concludes with a discussion of future challenges related to computer cooling technology.

[1]  R. C. Chu,et al.  Conduction cooling for an LSI package: a one-dimensional approach , 1982 .

[2]  Roger R. Schmidt,et al.  Cluster of High Powered Racks Within a Raised Floor Computer Data Center: Effect of Perforated Tile Flow Distribution on Rack Inlet Air Temperatures , 2003 .

[3]  C.E. Bash,et al.  Smart chip, system and data center enabled by advanced flexible cooling resources , 2005, Semiconductor Thermal Measurement and Management IEEE Twenty First Annual IEEE Symposium, 2005..

[4]  R. E. Bach,et al.  The ETA 10 liquid-nitrogen-cooled supercomputer system , 1989 .

[5]  M.F. Holahan,et al.  Fins, fans, and form: volumetric limits to air-side heat sink performance , 2004, The Ninth Intersociety Conference on Thermal and Thermomechanical Phenomena In Electronic Systems (IEEE Cat. No.04CH37543).

[6]  A. Bar-Cohen,et al.  Immersion Cooling of Digital Computers , 1994 .

[7]  K. Koide,et al.  Hardware technology for the Hitachi MP5800 series (HDS Skyline Series) , 2000 .

[8]  Roger R. Schmidt,et al.  Raised Floor Computer Data Center: Effect on Rack Inlet Temperatures When Adjacent Racks Are Removed , 2003 .

[9]  Roger R. Schmidt,et al.  Raised floor computer data center: effect on rack inlet temperatures of chilled air exiting both the hot and cold aisles , 2002, ITherm 2002. Eighth Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (Cat. No.02CH37258).

[10]  Dennis J. Herrell,et al.  High performance air cooled heat sinks for integrated circuits , 1990 .

[11]  Roger R. Schmidt,et al.  High-end server low-temperature cooling , 2002, IBM J. Res. Dev..

[12]  Herbert Reichl,et al.  High power multichip modules employing the planar embedding technique and microchannel water heat sinks , 1997, Thirteenth Annual IEEE. Semiconductor Thermal Measurement and Management Symposium.

[13]  G. B. Chai Large deflections of laminated composite plates , 1991 .

[14]  Akihiko Fujisaki,et al.  Packaging technology for high performance CMOS server Fujitsu GS8900 , 2001 .

[15]  Cullen E. Bash,et al.  Thermal considerations in cooling large scale high compute density data centers , 2002, ITherm 2002. Eighth Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (Cat. No.02CH37258).

[16]  Sudipta K. Ray,et al.  An advanced multichip module (MCM) for high-performance UNIX servers , 2002, IBM J. Res. Dev..

[17]  A. E. Bergles,et al.  Evolution of cooling technology for electrical, electronic, and microelectronic equipment , 2003 .

[18]  Roger R. Schmidt,et al.  System cooling design for the water-cooled IBM Enterprise System/9000 processors , 1992, IBM J. Res. Dev..

[19]  Dirk Hanson,et al.  The New Alchemists: Silicon Valley and the Microelectronics Revolution , 1982 .

[20]  G.M. Chrysler,et al.  Jet impingement boiling of a dielectric coolant in narrow gaps , 1994, Proceedings of 1994 4th Intersociety Conference on Thermal Phenomena in Electronic Systems (I-THERM).

[21]  Gary F. Goth,et al.  Dual-tapered-piston (DTP) module cooling for IBM Enterprise System/9000 systems , 1992, IBM J. Res. Dev..

[22]  Taylor L. Booth,et al.  Design Education in Computer Science and Engineering , 1986, Computer.

[23]  R. Pease,et al.  High-performance heat sinking for VLSI , 1981, IEEE Electron Device Letters.

[24]  Wataru Nakayama,et al.  Heat Transfer in Electronic Packages , 1997 .

[25]  M. Yovanovich,et al.  Optimization of pin-fin heat sinks using entropy generation minimization , 2001, IEEE Transactions on Components and Packaging Technologies.

[26]  D. J. de Kock,et al.  Trade-off Design of Extruded Heat Sinks Using Mathematical Optimization , 2004 .

[27]  James Kolodzey,et al.  CRAY-1 Computer Technology , 1981 .

[28]  R. E. Simons,et al.  The evolution of IBM high performance cooling technology , 1995, Proceedings of 1995 IEEE/CPMT 11th Semiconductor Thermal Measurement and Management Symposium (SEMI-THERM).

[29]  Charles B. Handy,et al.  The New Alchemists , 1999 .

[30]  Cullen E. Bash,et al.  Computational Fluid Dynamics Modeling of High Compute Density Data Centers to Assure System Inlet Air Specifications , 2001 .

[31]  Yuan Taur,et al.  CMOS devices below 0.1 /spl mu/m: how high will performance go? , 1997, International Electron Devices Meeting. IEDM Technical Digest.

[32]  Akio Takahashi,et al.  Hardware technology for Hitachi M-880 processor group , 1991, 1991 Proceedings 41st Electronic Components & Technology Conference.

[33]  R. C. Chu,et al.  Cooling Technology for High Performance Computers: IBM Sponsored University Research , 1994 .

[34]  S. L. Titcomb,et al.  Low-temperature CMOS-a brief preview , 1991 .

[35]  Yiding Cao,et al.  Flat and U-Shaped Heat Spreaders for High-Power Electronics , 2003 .

[36]  R. C. Chu,et al.  Cooling Technology for High Performance Computers: Design Applications , 1994 .

[37]  Cullen E. Bash,et al.  Smart cooling of data centers , 2003 .

[38]  Cullen E. Bash,et al.  Efficient Thermal Management of Data Centers—Immediate and Long-Term Research Needs , 2003 .

[39]  Ridvan A. Sahan,et al.  Cooling Solution for Next Generation High-Power Processor Boards in 1U Computer Servers , 2003 .

[40]  Roger R. Schmidt,et al.  Raised Floor Computer Data Center: Effect of Rack Inlet Temperatures When Rack Flowrates Are Reduced , 2003 .

[41]  Z. Z. Yu,et al.  The precision-engineered heat pipe for cooling Pentium II in CompactPCI design , 2000, ITHERM 2000. The Seventh Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (Cat. No.00CH37069).

[42]  Roger R. Schmidt,et al.  Raised Floor Computer Data Center: Effect on Rack Inlet Temperatures When High Powered Racks are Situated Amongst Lower Powered Racks , 2002 .

[43]  J.E.D. Northcote-Green,et al.  The use of computer aided distribution planning and design for the development of Urban Master Plans , 1989 .

[44]  Issam Mudawar,et al.  Critical heat flux in subcooled flow boiling of fluorocarbon liquid on a simulated electronic chip in a vertical rectangular channel , 1989 .

[45]  Lanchao Lin,et al.  Heat transfer characteristics of spray cooling in a closed loop , 2003 .

[46]  T. Cader,et al.  Implementing spray cooling thermal management in high heat flux applications , 2004, The Ninth Intersociety Conference on Thermal and Thermomechanical Phenomena In Electronic Systems (IEEE Cat. No.04CH37543).

[47]  Gian Piero Celata Critical Heat Flux in Subcooled Flow Boiling , 1998 .