27 MHz conformal capacitive ring (CR) applicators for uniform hyperthermic/diathermic treatment of body segments with axial fields

The devices consist of a pair of ringlike, flexible capacitive electrodes, conformally wrapped round the tissue to be heated. These capacitive ring (CR) applicators produce an axial E-field which can uniformly heat the central portion of a 20-cm OD cylindrical phantom simulating fat and muscle tissues. This electrode-body configuration can be used to heat most human body segments uniformly with the highest symmetry congruence, the RF currents flowing parallel to the boundaries provided by the pseudoaxial symmetry of these segments. With respect to the rigid pads used in RF capacitive heating, the CR electrodes exhibit a larger working surface area. Moreover, they can be used with an interposed dielectric layer between the electrodes and the skin to reduce edge effects. With respect to the axially symmetric radiators of higher frequency, they are applicable to larger cross-section body segments with increased penetration and without the need of an integral water bolus. The CR devices allow free access to most of the body surface for skin temperature measurement and conditioning and for combined treatments.<<ETX>>

[1]  C.A. Tiberio,et al.  The RF toroidal transformer as a heat delivery system for regional hyperthermia , 1988, IEEE Transactions on Biomedical Engineering.

[2]  M. Lilly,et al.  A practical system for clinical radiofrequency hyperthermia. , 1981, International journal of radiation oncology, biology, physics.

[3]  Cafiero Franconi,et al.  Hyperthermia Heating Technology and Devices , 1987 .

[4]  P. M. Berg,et al.  A three-dimensional model for the 'coaxial TEM' deep-body hyperthermia applicator. , 1986 .

[5]  J. Lagendijk A new coaxial TEM radiofrequency/microwave applicator for non-invasive deep-body hyperthermia. , 1983, The Journal of microwave power.

[6]  Calculation of Electromagnetic Power Deposition , 1987 .

[7]  H. Leveen,et al.  Tumor eradication by radiofrequency therapy. Responses in 21 patients. , 1976, JAMA.

[8]  G. Sato,et al.  Phase-Controlled Circular Array Heating Equipment for Deep-Seated Tumors: Preliminary Experiments , 1986 .

[9]  J. W. Hand,et al.  Electromagnetic Applicators for Non-Invasive Local Hyperthermia , 1987 .

[10]  Paul F. Turner,et al.  Regional Hyperthermia with an Annular Phased Array , 1984, IEEE Transactions on Biomedical Engineering.

[11]  P. F. Turner,et al.  Mini-Annular Phased Array for Limb Hyperthermia , 1986 .

[12]  L. Begnozzi,et al.  Low-Frequency RF Twin-Dipole Applicator for Intermediate Depth Hyperthermia , 1986 .

[13]  Arthur W. Guy,et al.  Therapeutic applications of electromagnetic power , 1974 .

[14]  Roberto Olmi,et al.  The Polyacrylamide as a Phantom Material for Electromagnetic Hyperthermia Studies , 1984, IEEE Transactions on Biomedical Engineering.

[15]  G. Nussbaum,et al.  Manipulation of Central Axis Heating Patterns with a Prototype, Three-Electrode Capacitive Device for Deep-Tumor Hyperthermia , 1986 .

[16]  J. Andersen Electromagnetic Power Deposition: Inhomogeneous Media, Applicators and Phased Arrays , 1987 .

[17]  E S Sternick,et al.  Thermal energy deposition from a single-loop rf whole-body applicator. , 1983, Medical physics.