The interference threshold of unipolar cardiac pacemakers in extremely low frequency magnetic fields

The effective induction loop area of implanted cardiac pacemaker (CPM) systems in magnetic fields was determined. The results were verified in a tank model placed in the centre of a Helmholtz-coil-arrangement. Both a left and a right pectorally implanted unipolar dual chamber CPM system were simulated. On this basis and with the results of benchmark-tests the interference thresholds for a collection of modern CPMs in extremely low frequency (ELF) magnetic fields were estimated. The investigations clearly showed that there are two loops, the CPM-lead-tissue-loop and the body loop, responsible for the magnitude of the disturbance voltage on the input of a cardiac pacemaker. The effective induction loop areas ranged from 100 to 221 cm2. For a left pectorally implanted, atrially controlled CPM system the interference thresholds for the magnetic induction lay between 16 and 552 µ T (RMS) for frequencies of the magnetic field between 10 and 250 Hz. Thus, there is a limited possibility for an interference of implanted CPMs by ELF magnetic fields in everyday life.

[1]  W. Irnich,et al.  Electromagnetic Interference in Implantable Pacemakers * , 1978, Pacing and clinical electrophysiology : PACE.

[2]  N P Smyth,et al.  Effects of active magnetic fields on permanently implanted triggered pacemakers. , 1973, Medical instrumentation.

[3]  M. Stuchly,et al.  Interaction of low-frequency electric and magnetic fields with the human body , 2000, Proceedings of the IEEE.

[4]  S. Pinski,et al.  Interference with cardiac pacing. , 2000, Cardiology clinics.

[5]  E. H. Lucas,et al.  The Effects of Electronic Article Surveillance Systems on Permanent Cardiac Pacemakers: An In Vitro Study , 1994, Pacing and clinical electrophysiology : PACE.

[6]  M. McIvor,et al.  Study of Pacemaker and Implantable Cardioverter Defibrillator Triggering by Electronic Article Surveillance Devices (SPICED TEAS) , 1998, Pacing and clinical electrophysiology : PACE.

[7]  BERNARD DODINOT,et al.  Electronic Article Surveillance: A Possible Danger for Pacemaker Patients , 1993, Pacing and clinical electrophysiology : PACE.

[8]  N. Smyth,et al.  The behavior of triggered unipolar pacemakers in active magnetic fields. , 1972, The Journal of thoracic and cardiovascular surgery.

[9]  A. Silny The interference threshold of cardiac pacemakers in electric 50 Hz fields , 2001, Journal of medical engineering & technology.

[10]  J. Mugica,et al.  Study of Interactions Between Permanent Pacemakers and Electronic Antitheft Surveillance Systems , 2000, Pacing and clinical electrophysiology : PACE.

[11]  W. Irnich Herzschrittmacherpatienten unter Hochspannungsleitungen , 1999, Herzschrittmachertherapie und Elektrophysiologie.

[12]  J. A. Woody,et al.  Cardiac Pacemaker Responses to Power Frequency Signals , 1978, 1978 IEEE International Symposium on Electromagnetic Compatibility.

[13]  M. Pitkänen,et al.  The influence of electromagnetic interference and ionizing radiation on cardiac pacemakers. , 1990, Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al].

[14]  Markus Zahn,et al.  Electromagnetic Field Theory: A Problem Solving Approach , 2003 .

[15]  L Toivonen,et al.  The Influence of Elevated 50 Hz Electric and Magnetic Fields on Implanted Cardiac Pacemakers: The Role of the Lead Configuration and Programming of the Sensitivity , 1991, Pacing and clinical electrophysiology : PACE.