Cardiac-like flow generator for long-term imaging of endothelial cell responses to circulatory pulsatile flow at microscale.

In vitro models of circulatory hemodynamics are required to mimic the microcirculation for study of endothelial cell responses to pulsatile shear stress by live cell imaging. This study reports the design, fabrication and characterisation of a microfluidic device that generates cardiac-like flow in a continuous culture system with a circulatory volume of only 2-3 μL. The device mimics a single chamber heart, with the following cardiac phases: (1) closure of the ventricle inlet valve, (2) contraction of the ventricle (systole) followed by opening of the outlet valve and (3) relaxation of the ventricle (diastole) with opening of the inlet valve whilst the outlet valve remains closed. Periodic valve states and ventricular contractions were actuated by microprocessor controlled pneumatics. The time-dependent velocity-field was characterised by micro-particle image velocimetry (μ-PIV). μ-PIV observations were used to help tune electronic timing of valve states and ventricular contractions for synthesis of an arterial pulse waveform to study the effect of pulsatile shear stress on bovine artery endothelial cells (BAECs). BAECs elongated and aligned with the direction of shear stress after 48 h of exposure to a pulsatile waveform with a maximum shear stress of 0.42 Pa. The threshold for BAECs alignment and elongation under steady (non-pulsatile) flow reported by Kadohama et al. (2006) is 0.7-1.4 Pa. These cells respond to transient shear stress because the time average shear stress of the pulse waveform to generate this morphological response was only 0.09 Pa, well below the steady flow threshold. The microfluidic pulse generator can simulate circulatory hemodynamics for live cell imaging of shear-induced signalling pathways.

[1]  G. Garcı́a-Cardeña,et al.  Early adaptive responses of the vascular wall during venous arterialization in mice. , 2004, The American journal of pathology.

[2]  George M Whitesides,et al.  The pressure drop along rectangular microchannels containing bubbles. , 2007, Lab on a chip.

[3]  Arnan Mitchell,et al.  A shear gradient–dependent platelet aggregation mechanism drives thrombus formation , 2009, Nature Medicine.

[4]  Palaniappan Sethu,et al.  Microfluidic endothelial cell culture model to replicate disturbed flow conditions seen in atherosclerosis susceptible regions. , 2011, Biomicrofluidics.

[5]  B. Milthorpe,et al.  An experimental model of affinity cell separation. , 1994, Cytometry.

[6]  Huaying Chen,et al.  Design of microdevices for long-term live cell imaging , 2012 .

[7]  Craig A Simmons,et al.  Macro- and microscale fluid flow systems for endothelial cell biology. , 2010, Lab on a chip.

[8]  Hui Zhao,et al.  Integrated microfluidic chip for endothelial cells culture and analysis exposed to a pulsatile and oscillatory shear stress. , 2009, Lab on a chip.

[9]  Kapil Pant,et al.  SyM-BBB: a microfluidic Blood Brain Barrier model. , 2013, Lab on a chip.

[10]  B. Zweifach,et al.  Quantitative studies of microcirculatory structure and function. III. Microvascular hemodynamics of cat mesentery and rabbit omentum. , 1977, Circulation research.

[11]  Arndt F. Siekmann,et al.  Arterial-venous network formation during brain vascularization involves hemodynamic regulation of chemokine signaling , 2011, Development.

[12]  D. Ingber,et al.  Reconstituting Organ-Level Lung Functions on a Chip , 2010, Science.

[13]  Deborah K. Lieu,et al.  Microchannel Platform for the Study of Endothelial Cell Shape and Function , 2002 .

[14]  Nozomi Nishimura,et al.  In vivo two-photon excited fluorescence microscopy reveals cardiac- and respiration-dependent pulsatile blood flow in cortical blood vessels in mice. , 2012, American journal of physiology. Heart and circulatory physiology.

[15]  S. Bolz,et al.  A microfluidic platform for probing small artery structure and function. , 2010, Lab on a chip.

[16]  George Q. Daley,et al.  Biomechanical forces promote embryonic haematopoiesis , 2009, Nature.

[17]  R. Franke,et al.  Induction of human vascular endothelial stress fibres by fluid shear stress , 1984, Nature.

[18]  L. McIntire,et al.  Response of cultured endothelial cells to steady flow. , 1984, Microvascular research.

[19]  J. Panza,et al.  Role of Endothelial Nitric Oxide in Shear Stress—Induced Vasodilation of Human Microvasculature: Diminished Activity in Hypertensive and Hypercholesterolemic Patients , 2001, Circulation.

[20]  Jerry Westerweel,et al.  In vivo micro particle image velocimetry measurements of blood-plasma in the embryonic avian heart. , 2006, Journal of biomechanics.

[21]  G. Garcı́a-Cardeña,et al.  A new in vitro model to evaluate differential responses of endothelial cells to simulated arterial shear stress waveforms. , 2002, Journal of biomechanical engineering.

[22]  L K Chin,et al.  Production of reactive oxygen species in endothelial cells under different pulsatile shear stresses and glucose concentrations. , 2011, Lab on a chip.

[23]  Hanseup Kim,et al.  Characterization of a microfluidic in vitro model of the blood-brain barrier (μBBB). , 2012, Lab on a chip.

[24]  S. Quake,et al.  Monolithic microfabricated valves and pumps by multilayer soft lithography. , 2000, Science.

[25]  A M Melkumyants,et al.  Endothelium dependent control of arterial diameter by blood viscosity. , 1989, Cardiovascular research.

[26]  B. Berk,et al.  Laminar shear stress: mechanisms by which endothelial cells transduce an atheroprotective force. , 1998, Arteriosclerosis, thrombosis, and vascular biology.

[27]  G Kaley,et al.  Role of shear stress and endothelial prostaglandins in flow- and viscosity-induced dilation of arterioles in vitro. , 1993, Circulation research.

[28]  Hyunjae Lee,et al.  Engineering of functional, perfusable 3D microvascular networks on a chip. , 2013, Lab on a chip.

[29]  R. Pettigrew,et al.  Determination of wall shear stress in the aorta with the use of MR phase velocity mapping , 1995, Journal of magnetic resonance imaging : JMRI.

[30]  P Boesiger,et al.  Human abdominal aorta: comparative measurements of blood flow with MR imaging and multigated Doppler US. , 1989, Radiology.

[31]  R M Nerem,et al.  Vascular endothelial morphology as an indicator of the pattern of blood flow. , 1981, Journal of biomechanical engineering.

[32]  Shin-Ichi Nishikawa,et al.  Continuous single-cell imaging of blood generation from haemogenic endothelium , 2009, Nature.

[33]  D. Stainier,et al.  Hematopoietic stem cells derive directly from aortic endothelium during development , 2009, Nature.

[34]  G. Giridharan,et al.  Endothelial cell culture model for replication of physiological profiles of pressure, flow, stretch, and shear stress in vitro. , 2011, Analytical chemistry.

[35]  B. Sumpio,et al.  p38 Mitogen-activated protein kinase activation in endothelial cell is implicated in cell alignment and elongation induced by fluid shear stress. , 2006, Endothelium : journal of endothelial cell research.

[36]  Huaying Chen,et al.  Microwell perfusion array for high-throughput, long-term imaging of clonal growth. , 2011, Biomicrofluidics.