Review of magnetic methods for nondestructive evaluation (Part 2)
暂无分享,去创建一个
[1] W. Stumm. Tube testing by electromagnetic ndt methods — 1 , 1974 .
[2] W. G. Clark,et al. Stress mapping with eddy currents , 1984 .
[3] D. L. Atherton,et al. The remote-field through-wall electromagnetic inspection technique for pressure tubes , 1986 .
[4] V. E. Shcherbinin,et al. Effect of the magnetizing method on the detectability of defects in welded joints in electric welded pipes , 1985 .
[5] R. E. Beissner,et al. Correlations Between Advanced Nondestructive Evaluation Methods and Fracture Mechanics Parameters , 1980 .
[6] James Lankford,et al. Advanced Nondestructive Testing Methods for Bearing Inspection , 1972 .
[7] David L. Atherton,et al. Finite element calculation of magnetic flux leakage detector signals , 1987 .
[8] K. F. Bainton. Characterizing defects by determining magnetic leakage fields , 1977 .
[9] T. R. Schmidt. The remote field eddy current inspection technique , 1984 .
[10] S B Palmer,et al. The magnetic leakage field of surface-breaking cracks , 1986 .
[11] David L. Atherton,et al. Finite element calculations on the effects of permeability variation on magnetic flux leakage signals , 1987 .
[12] L. J. Swartzendruber,et al. On the optimum applied field for magnetic particle inspection using direct current , 1982 .
[13] William Lord. Electromagnetic Methods of Nondestructive Testing , 1985 .
[14] H. Libby. Introduction to Electromagnetic Nondestructive Test Methods , 1971 .
[15] T. R. Schmidt. The Casing Inspection Tool — An Instrument for the In-Situ Detection Of External Casing Corrosion in Oil Wells , 1961 .
[16] David Jiles,et al. Review of magnetic methods for nondestructive evaluation , 1988 .
[17] Derek P. Atherton. Finite element calculations and computer measurements of magnetic flux leakage patterns for pits , 1988 .
[18] F. Förster. New findings in the field of non-destructive magnetic leakage field inspection , 1986 .
[19] F. Forster. On the way from the «Know-haw» to the «Know-why» in the magnetic leakage field method of nondestructive testing. I , 1985 .
[20] B. Brudar,et al. Magnetic leakage fields calculated by the method of finite differences , 1985 .
[21] D. L. Atherton,et al. Distinction between near and far-side corrosion pit signals using magnetic leakage flux detectors , 1988, Canadian Electrical Engineering Journal.
[22] C. V. Dodd,et al. Eddy current inspection of steam generator tubing : Electromagnetic methods of nondestructive testing. Edited by William Lord. Nondestructive testing monographs and tracts, vol. 3, pp. 175–193. Gordon and Breach Science Publishers (1985) , 1989 .
[23] W. Lord. Applications of numerical field modeling to electromagnetic methods of nondestructive testing , 1983 .
[24] Derek P. Atherton. The application of finite-element calculations to the remote-field inspection technique , 1987 .
[25] G. M. Massa. Finding the optimum conditions for weld testing by magnetic particles , 1976 .
[26] S. B. Palmer,et al. The prod magnetization method of magnetic particle inspection , 1983 .
[27] Yr Fiorini,et al. Finite Element Modeling of Magnetic Field/Defect Interactions , 1975 .
[28] David L. Atherton. Stress-shadow magnetic inspection technique for far-side anomalies in steel pipe , 1983 .
[29] F. Förster. Developments in the magnetography of tubes and tube welds , 1975 .
[30] S. B. Palmer,et al. An analysis of the threading bar method of magnetic particle flaw detection , 1981 .
[31] David L. Atherton,et al. Detection of anomalous stresses in gas pipelines by magnetometer survey (invited) , 1982 .