Power Quality Improvement of Power Distribution System Under Symmetrical and Unsymmetrical Faults Using D-STATCOM

Voltage and current waveform distortion is a most important power quality concern, because a small fluctuation with phase supply, transient condition occurs and unbalanced of phase voltage can create a more derange within phase currents. Three phase balanced system holds only positive sequence constituents of voltage, current, and impedance, whereas both positive and negative sequence constituents of voltages and currents within unbalanced system. The voltages at the generation system side are in sinusoidal wave and have constant equivalent magnitude value within 120° phase difference. However, unbalanced condition arises due to inadequacy in voltage magnitude and in fundamental frequency in load side. This paper proposes the shunt-connected current inserting Distribution Static Synchronous Compensator (D-STATCOM) through appropriate controlling scheme to moderate and compensate the unstable load current. It works as quick reimbursing source for reactive power that is functional on the distribution power system to moderate voltage deviations like voltage sags, swells, and voltage flicker along with unsteadiness produced by quickly changing reactive power demand. This paper presents the scheme and Simulink model of D-STATCOM within PI controller toward improving the superiority of power under dissimilar irregular circumstances like symmetrical and unsymmetrical faults. The controller working efficiency is tested under different fault conditions. The performance of D-STATCOM under different fault conditions in power distribution system is carried out at three phase supply 20 kV, 50 Hz. The controller and D-STATCOM model are designed through Simulink and Power System Blockset toolbox existing in MATLAB program.

[1]  B.P. Muni,et al.  SVPWM Switched DSTATCOM for Power Factor and Voltage Sag Compensation , 2006, 2006 International Conference on Power Electronic, Drives and Energy Systems.

[2]  B. Singh,et al.  Three-phase four-wire dstatcom with H-bridge VSC and star/delta transformer for power quality improvement , 2008, 2008 Annual IEEE India Conference.

[3]  B. Singh,et al.  Three-Phase 4-Wire DSTATCOM Based on H-Bridge VSC with a Star/Hexagon Transformer for Power Quality Improvement , 2008, 2008 IEEE Region 10 and the Third international Conference on Industrial and Information Systems.

[4]  Arindam Ghosh,et al.  Inverter control using output feedback for power compensating devices , 2003, TENCON 2003. Conference on Convergent Technologies for Asia-Pacific Region.

[5]  Dong-Seok Hyun,et al.  The distribution STATCOM for reducing the effect of voltage sag and swell , 2001, IECON'01. 27th Annual Conference of the IEEE Industrial Electronics Society (Cat. No.37243).

[6]  Amit Kumar,et al.  Mitigation of voltage sag/swell and harmonics using self-supported DVR , 2016, 2016 IEEE 1st International Conference on Power Electronics, Intelligent Control and Energy Systems (ICPEICES).

[7]  M. Tavakoli Bina,et al.  Design and installation of a ±250 kVAr D-STATCOM for a distribution substation , 2005 .

[8]  Muammer Ermis,et al.  Design and Implementation of a Current-Source Converter for Use in Industry Applications of D-STATCOM , 2010, IEEE Transactions on Power Electronics.

[9]  Sangyoung Park,et al.  The modeling and analysis of shunt type custom power device , 2001, 2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194).

[10]  Mahesh K. Mishra,et al.  A Voltage-Controlled DSTATCOM for Power-Quality Improvement , 2014, IEEE Transactions on Power Delivery.

[11]  M.T. Bina,et al.  Consequence of unbalance supplying condition on a distribution static compensator , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[12]  M. K. Mishra,et al.  Synchronous reference frame based current controller with SPWM switching strategy for DSTATCOM applications , 2012, 2012 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES).

[13]  Bor-Ren Lin,et al.  Analysis and implementation of a NPC-based DSTATCOM under the abnormal voltage conditions , 2005, 2005 IEEE International Conference on Industrial Technology.

[14]  B. Singh,et al.  A T-Connected Transformer and Three-leg VSC Based DSTATCOM for Power Quality Improvement , 2008, IEEE Transactions on Power Electronics.

[15]  B. Singh,et al.  Power Quality Enhancement with DSTATCOM for Small Isolated Alternator feeding Distribution System , 2005, 2005 International Conference on Power Electronics and Drives Systems.