End-To-End Deep Learning Architecture for Continuous Blood Pressure Estimation Using Attention Mechanism

Blood pressure (BP) is a vital sign that provides fundamental health information regarding patients. Continuous BP monitoring is important for patients with hypertension. Various studies have proposed cuff-less BP monitoring methods using pulse transit time. We propose an end-to-end deep learning architecture using only raw signals without the process of extracting features to improve the BP estimation performance using the attention mechanism. The proposed model consisted of a convolutional neural network, a bidirectional gated recurrent unit, and an attention mechanism. The model was trained by a calibration-based method, using the data of each subject. The performance of the model was compared to the model that used each combination of the three signals, and the model with the attention mechanism showed better performance than other state-of-the-art methods, including conventional linear regression method using pulse transit time (PTT). A total of 15 subjects were recruited, and electrocardiogram, ballistocardiogram, and photoplethysmogram levels were measured. The 95% confidence interval of the reference BP was [86.34, 143.74] and [51.28, 88.74] for systolic BP (SBP) and diastolic BP (DBP), respectively. The R2 values were 0.52 and 0.49, and the mean-absolute-error values were 4.06 ± 4.04 and 3.33 ± 3.42 for SBP and DBP, respectively. In addition, the results complied with global standards. The results show the applicability of the proposed model as an analytical metric for BP estimation.

[1]  Cheolsoo Park,et al.  Recognition of Human Motion with Deep Reinforcement Learning , 2018 .

[2]  Rohan Ramanath,et al.  An Attentive Survey of Attention Models , 2019, ACM Trans. Intell. Syst. Technol..

[3]  Yoshua Bengio,et al.  Learning long-term dependencies with gradient descent is difficult , 1994, IEEE Trans. Neural Networks.

[4]  Ying Xing,et al.  A Novel Neural Network Model for Blood Pressure Estimation Using Photoplethesmography without Electrocardiogram , 2018, Journal of healthcare engineering.

[5]  Sayup Kim,et al.  A Chair-Based Unconstrained/Nonintrusive Cuffless Blood Pressure Monitoring System Using a Two-Channel Ballistocardiogram , 2019, Sensors.

[6]  Yuan-Ting Zhang,et al.  Pulse transit time technique for cuffless unobtrusive blood pressure measurement: from theory to algorithm , 2019, Biomedical Engineering Letters.

[7]  Jimmy Ba,et al.  Adam: A Method for Stochastic Optimization , 2014, ICLR.

[8]  Lukasz Kaiser,et al.  Attention is All you Need , 2017, NIPS.

[9]  Christopher D. Manning,et al.  Effective Approaches to Attention-based Neural Machine Translation , 2015, EMNLP.

[10]  Robert M Carey,et al.  The 2017 American College of Cardiology/American Heart Association Clinical Practice Guideline for High Blood Pressure in Adults. , 2018, JAMA cardiology.

[11]  Carmen C. Y. Poon,et al.  Cuff-less and Noninvasive Measurements of Arterial Blood Pressure by Pulse Transit Time , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[12]  Willis J. Tompkins,et al.  A Real-Time QRS Detection Algorithm , 1985, IEEE Transactions on Biomedical Engineering.

[13]  Mahdi Shabany,et al.  Cuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring , 2017, IEEE Transactions on Biomedical Engineering.

[14]  Ihsan Ullah,et al.  An Automated System for Epilepsy Detection using EEG Brain Signals based on Deep Learning Approach , 2018, Expert Syst. Appl..

[15]  Sayanti Chaudhuri,et al.  Obstructive sleep apnoea detection using convolutional neural network based deep learning framework , 2017, Biomedical Engineering Letters.

[16]  Yuan-Ting Zhang,et al.  Long-term blood pressure prediction with deep recurrent neural networks , 2017, 2018 IEEE EMBS International Conference on Biomedical & Health Informatics (BHI).

[17]  T. Pickering Principles and techniques of blood pressure measurement. , 2002, Cardiology clinics.

[18]  Mitja Lustrek,et al.  Blood Pressure Estimation from Photoplethysmogram Using a Spectro-Temporal Deep Neural Network , 2019, Sensors.

[19]  U. Rajendra Acharya,et al.  Automated diagnosis of arrhythmia using combination of CNN and LSTM techniques with variable length heart beats , 2018, Comput. Biol. Medicine.

[20]  Yoshua Bengio,et al.  Show, Attend and Tell: Neural Image Caption Generation with Visual Attention , 2015, ICML.

[21]  Yoshua Bengio,et al.  Empirical Evaluation of Gated Recurrent Neural Networks on Sequence Modeling , 2014, ArXiv.

[22]  U. Rajendra Acharya,et al.  Arrhythmia detection using deep convolutional neural network with long duration ECG signals , 2018, Comput. Biol. Medicine.

[23]  Jeffrey M. Hausdorff,et al.  Physionet: Components of a New Research Resource for Complex Physiologic Signals". Circu-lation Vol , 2000 .

[24]  T. Togawa,et al.  Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration , 2000, Medical and Biological Engineering and Computing.

[25]  Jürgen Schmidhuber,et al.  Long Short-Term Memory , 1997, Neural Computation.

[26]  Carmen C. Y. Poon,et al.  An Evaluation of the Cuffless Blood Pressure Estimation Based on Pulse Transit Time Technique: a Half Year Study on Normotensive Subjects , 2009, Cardiovascular engineering.

[27]  Yoshua Bengio,et al.  Learning Phrase Representations using RNN Encoder–Decoder for Statistical Machine Translation , 2014, EMNLP.

[28]  Ko Keun Kim,et al.  A Smart Health Monitoring Chair for Nonintrusive Measurement of Biological Signals , 2012, IEEE Transactions on Information Technology in Biomedicine.

[29]  Md. Kamrul Hasan,et al.  Cuffless blood pressure estimation from electrocardiogram and photoplethysmogram using waveform based ANN-LSTM network , 2018, Biomed. Signal Process. Control..

[30]  Andreas Spanias,et al.  Attend and Diagnose: Clinical Time Series Analysis using Attention Models , 2017, AAAI.

[31]  Youngchul Kim,et al.  Multimodal Drowsiness Detection Methods using Machine Learning Algorithms , 2018 .

[32]  Sebastiano Battiato,et al.  An Advanced Bio-Inspired PhotoPlethysmoGraphy (PPG) and ECG Pattern Recognition System for Medical Assessment , 2018, Sensors.

[33]  Y. T. Zhang,et al.  Noninvasive and cuffless measurements of blood pressure for telemedicine , 2001, 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[34]  Domenico Grimaldi,et al.  A Neural Network-based method for continuous blood pressure estimation from a PPG signal , 2013, 2013 IEEE International Instrumentation and Measurement Technology Conference (I2MTC).

[35]  Derek Abbott,et al.  Analysis of beat-to-beat blood pressure variability response to the cold pressor test in the offspring of hypertensive and normotensive parents , 2017, Hypertension Research.

[36]  F. Mee,et al.  Evaluation of blood pressure measuring devices. , 1993, Clinical and experimental hypertension.

[37]  Goo-Rak Kwon,et al.  CNN Models Performance Analysis on MRI images of OASIS dataset for distinction between Healthy and Alzheimer's patient , 2019, 2019 International Conference on Electronics, Information, and Communication (ICEIC).

[38]  Xin Wen,et al.  A Feasible Feature Extraction Method for Atrial Fibrillation Detection From BCG , 2020, IEEE Journal of Biomedical and Health Informatics.

[39]  Omer T. Inan,et al.  Ballistocardiogram as Proximal Timing Reference for Pulse Transit Time Measurement: Potential for Cuffless Blood Pressure Monitoring , 2015, IEEE Transactions on Biomedical Engineering.

[40]  Xiang Bai,et al.  An End-to-End Trainable Neural Network for Image-Based Sequence Recognition and Its Application to Scene Text Recognition , 2015, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[41]  Andrew Zisserman,et al.  Very Deep Convolutional Networks for Large-Scale Image Recognition , 2014, ICLR.

[42]  Yuan-Ting Zhang,et al.  Continuous Cuffless Blood Pressure Estimation Using Pulse Transit Time and Photoplethysmogram Intensity Ratio , 2016, IEEE Transactions on Biomedical Engineering.

[43]  Kwang Suk Park,et al.  Non-constrained monitoring of systolic blood pressure on a weighing scale , 2009, Physiological measurement.

[44]  Sergey Ioffe,et al.  Batch Normalization: Accelerating Deep Network Training by Reducing Internal Covariate Shift , 2015, ICML.

[45]  Douglas G. Altman,et al.  Measurement in Medicine: The Analysis of Method Comparison Studies , 1983 .

[46]  Yoshua Bengio,et al.  Neural Machine Translation by Jointly Learning to Align and Translate , 2014, ICLR.

[47]  Sooyoung Yoo,et al.  Validation of the mobile wireless digital automatic blood pressure monitor using the cuff pressure oscillometric method, for clinical use and self-management, according to international protocols , 2018, Biomedical engineering letters.

[48]  Daniel P. W. Ellis,et al.  Feed-Forward Networks with Attention Can Solve Some Long-Term Memory Problems , 2015, ArXiv.