Three-dimensional imaging and detection efficiency performance of orthogonal coplanar CZT strip detectors

We report on recent three-dimensional imaging performance and detection efficiency measurements obtained with 5 mm thick prototype CdZnTe detectors fabricated with orthogonal coplanar anode strips. In previous work, we have shown that detectors fabricated using this design achieve both very good energy resolution and sub-millimeter spatial resolution with fewer electronic channels than are required for pixel detectors. As electron-only devices, like pixel detectors, coplanar anode strip detectors can be fabricated in the thickness required to be effective imagers for photons with energies in excess of 500 keV. Unlike conventional double-sided strip detectors, the coplanar anode strip detectors require segmented contacts and signal processing electronics on only one surface. The signals can be processed to measure the total energy deposit and the photon interaction location in three dimensions. The measurements reported here provide a quantitative assessment of the detection capabilities of orthogonal coplanar anode strip detectors.

[1]  Valentin T. Jordanov,et al.  Signal formation in a CdZnTe imaging detector with coplanar pixel and control electrodes , 1999 .

[2]  W. Robert Binns,et al.  High-energy x-ray imaging spectrometer (HEXIS) , 1998, Optics & Photonics.

[3]  Valentin T. Jordanov,et al.  Multi-electrode CZT detector packaging using polymer flip chip bonding , 2001 .

[4]  Richard C. Puetter,et al.  Preliminary test results of a new high-energy-resolution silicon and CdZnTe pixel detectors for application to x-ray astronomy , 1999, Optics & Photonics.

[5]  Mark L. McConnell,et al.  Progress in the development of large-area submillimeter-resolution CdZnTe strip detectors , 1996, Optics & Photonics.

[6]  Valentin T. Jordanov,et al.  Biasing scheme for AC coupled strip detectors , 1997 .

[7]  James M. Ryan,et al.  Large-area sub-millimeter resolution CdZnTe strip detector for astronomy , 1996 .

[8]  J. Mayer Advanced packaging , 1986 .

[9]  R. Stephenson A and V , 1962, The British journal of ophthalmology.

[10]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[11]  Mark L. McConnell,et al.  Progress in the study of CdZnTe strip detectors , 1997, Optics & Photonics.

[12]  Mark L. McConnell,et al.  Large-area submillimeter resolution CdZnTe strip detector for astronomy , 1995, Optics & Photonics.

[13]  Francois Lebrun,et al.  ISGRI: a CdTe array imager for INTEGRAL , 1996, Optics & Photonics.

[14]  James M. Ryan,et al.  A balloon-borne coded aperture telescope for ARC-minute angular resolution at hard X-ray energies , 1998 .

[15]  James M. Ryan,et al.  Development of an orthogonal-stripe CdZnTe gamma radiation imaging spectrometer , 1995, 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record.

[16]  Valentin T. Jordanov,et al.  Analog processing of signals from a CZT strip detector with orthogonal coplanar anodes , 2000, SPIE Optics + Photonics.

[17]  Valentin T. Jordanov,et al.  An imaging CdZnTe detector with coplanar orthogonal anode strips , 1997 .

[18]  Louis-Andre Hamel,et al.  Energy and position resolution of a CdZnTe gamma-ray detector with orthogonal coplanar anodes , 1999, Optics & Photonics.

[19]  N. Gehrels,et al.  EXIST: A high sensitivity hard x-ray imaging sky survey mission for ISS , 2000 .

[20]  James M. Ryan,et al.  Development of an orthogonal-stripe CdZnTe gamma radiation imaging spectrometer , 1995 .

[21]  James M. Ryan,et al.  Performance and simulation of CdZnTe strip detectors as sub-millimeter resolution imaging gamma radiation spectrometers , 1997 .

[22]  Valentin T. Jordanov,et al.  The development of a position-sensitive CZT detector with orthogonal co-planar anode strips , 2000 .

[23]  Paul L. Hink,et al.  Position-sensitive CZT detector module , 1998, Optics + Photonics.

[24]  Allen D. Zych,et al.  Coded-aperture x-ray/gamma-ray telescope for arc-minute localization of gamma-ray bursts , 1999, Optics & Photonics.