Interplay of tumor vascular oxygenation and tumor pO2 observed using near-infrared spectroscopy, an oxygen needle electrode, and 19F MR pO2 mapping.

This study investigates the correlation of tumor blood oxygenation and tumor pO(2) with respect to carbogen inhalation. After having refined and validated the algorithms for calculating hemoglobin concentrations, we used near-infrared spectroscopy (NIRS) to measure changes of oxygenated hemoglobin concentration (delta[HbO(2)]) and used an oxygen needle electrode and (19)F MRI for pO(2) measurements in tumors. The measurements were taken from Dunning prostate R3327 tumors implanted in rats, while the anesthetized rats breathed air or carbogen. The NIRS results from tumor measurements showed significant changes in tumor vascular oxygenation in response to carbogen inhalation, while the pO(2) electrode results showed an apparent heterogeneity for tumor pO(2) response to carbogen inhalation, which was also confirmed by (19)F MR pO(2) mapping. Furthermore, we developed algorithms to estimate hemoglobin oxygen saturation, sO(2), during gas intervention based on the measured values of delta[HbO(2)] and pO(2). The algorithms have been validated through a tissue-simulating phantom and used to estimate the values of sO(2) in the animal tumor measurement based on the NIRS and global mean pO(2) values. This study demonstrates that the NIRS technology can provide an efficient, real-time, noninvasive approach to monitoring tumor physiology and is complementary to other techniques, while it also demonstrates the need for an NIR imaging technique to study spatial heterogeneity of tumor vasculature under therapeutic interventions.

[1]  C. Blum,et al.  Regional tumor oxygenation and measurement of dynamic changes. , 1999, Radiation research.

[2]  E. Hull,et al.  Carbogen-induced changes in rat mammary tumour oxygenation reported by near infrared spectroscopy , 1999, British Journal of Cancer.

[3]  Britton Chance,et al.  Influence of blood vessels on the measurement of hemoglobin oxygenation as determined by time-resolved reflectance spectroscopy. , 1995, Medical physics.

[4]  R. Mason,et al.  Oxygen tension mapping with F‐19 echo‐planar MR imaging of sequestered perfluorocarbon , 1994, Journal of magnetic resonance imaging : JMRI.

[5]  F. Léon-Velarde,et al.  Respiratory Physiology , 2018, People and Ideas.

[6]  K. Hiramoto,et al.  [Gas transport]. , 1978, Kokyu to junkan. Respiration & circulation.

[7]  R. Mason,et al.  Noninvasive investigation of blood oxygenation dynamics of tumors by near-infrared spectroscopy. , 2000, Applied optics.

[8]  W. Zijlstra,et al.  Absorption spectra of human fetal and adult oxyhemoglobin, de-oxyhemoglobin, carboxyhemoglobin, and methemoglobin. , 1991, Clinical chemistry.

[9]  J. Debus,et al.  MR-tomographische Quantifizierung struktureller und funktioneller Gewebeveränderungen an stoßwellentherapierten Dunning-Prostata-Tumoren , 1993 .

[10]  R. Grant Steen,et al.  In vivo measurement of tumor blood oxygenation by near-infrared spectroscopy: Immediate effects of pentobarbital overdose or carmustine treatment , 2005, Journal of Neuro-Oncology.

[11]  T L Phillips,et al.  Oxygen in human tumors: correlations between methods of measurement and response to therapy. Summary of a workshop held November 19-20, 1992, at the National Cancer Institute, Bethesda, Maryland. , 1993, Radiation research.

[12]  G Zaccanti,et al.  Time-resolved spectroscopy of the human forearm. , 1992, Journal of photochemistry and photobiology. B, Biology.

[13]  S Nioka,et al.  Quantitation of time- and frequency-resolved optical spectra for the determination of tissue oxygenation. , 1991, Analytical biochemistry.

[14]  R. Mason,et al.  Tumor Oxygen Dynamics with Respect to Growth and Respiratory Challenge: Investigation of the Dunning Prostate R3327-HI Tumor1 , 2001, Radiation research.

[15]  J. Overgaard,et al.  Modification of Hypoxia-Induced Radioresistance in Tumors by the Use of Oxygen and Sensitizers. , 1996, Seminars in radiation oncology.

[16]  P. Antich,et al.  Tumor oximetry: demonstration of an enhanced dynamic mapping procedure using fluorine-19 echo planar magnetic resonance imaging in the Dunning prostate R3327-AT1 rat tumor. , 2001, International journal of radiation oncology, biology, physics.

[17]  L. H. Gray,et al.  The concentration of oxygen dissolved in tissues at the time of irradiation as a factor in radiotherapy. , 1953, The British journal of radiology.

[18]  I. Silver,et al.  Quantitative measurements of oxygen tension in normal tissues and in the tumours of patients before and after radiotherapy. , 1960, Acta radiologica.

[19]  P Peschke,et al.  Isolated tumor growth in a surgically formed skin pedicle in the rat: a new tumor model for NMR studies. , 1993, Magnetic resonance imaging.

[20]  H Liu Unified analysis of the sensitivities of reflectance and path length to scattering variations in a diffusive medium. , 2001, Applied optics.

[21]  F. Lohr,et al.  Differential sensitivity of three sublines of the rat Dunning prostate tumor system R3327 to radiation and/or local tumor hyperthermia. , 1998, Radiation research.

[22]  Ja-Chen Lin,et al.  HYBRID ADAPTIVE BLOCK TRUNCATION CODING FOR IMAGE COMPRESSION , 1997 .

[23]  E. Demidenko,et al.  Effect on regrowth delay in a murine tumor of scheduling split-dose irradiation based on direct pO2 measurements by electron paramagnetic resonance oximetry. , 1998, Radiation research.

[24]  S. Arridge,et al.  Estimation of optical pathlength through tissue from direct time of flight measurement , 1988 .

[25]  R. Fournier Basic Transport Phenomena In Biomedical Engineering , 1998 .

[26]  P. Antich,et al.  A noninvasive assessment of myocardial oxygen tension: 19f nmr spectroscopy of sequestered perfluorocarbon emulsion , 1992, Magnetic resonance in medicine.

[27]  J. Kaanders,et al.  Accelerated radiotherapy with carbogen and nicotinamide (ARCON) for laryngeal cancer. , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[28]  J. Desimone Principles and models of biological transport , 1987 .

[29]  B. Wilson,et al.  Time resolved reflectance and transmittance for the non-invasive measurement of tissue optical properties. , 1989, Applied optics.

[30]  Hanli Liu,et al.  Low-cost frequency-domain photon migration instrument for tissue spectroscopy, oximetry, and imaging , 1997 .

[31]  S. Arridge,et al.  Experimentally measured optical pathlengths for the adult head, calf and forearm and the head of the newborn infant as a function of inter optode spacing. , 1992, Advances in experimental medicine and biology.