Evaluation of the effect of computed tomography scan protocols and freeform fabrication methods on bone biomodel accuracy.

OBJECTIVE To assess the effect of computed tomography (CT) scan protocols (radiation amounts) and fabrication methods on biomodel accuracy and variability. SAMPLE Cadaveric femur of a Basset Hound. PROCEDURES Retroreconstructions (n = 158) were performed of 16 original scans and were visually inspected to select 17 scans to be used for biomodel fabrication. Biomodels of the 17 scans were made in triplicate by use of 3 freeform fabrication processes (stereolithography, fused deposition modeling, and 3-D printing) for 153 models. The biomodels and original bone were measured by use of a coordinate measurement machine. RESULTS Differences among fabrication methods accounted for 2% to 29% of the total observed variation in inaccuracy and differences among method-specific radiation configurations accounted for 4% to 44%. Biomodels underestimated bone length and width and femoral head diameter and overestimated cortical thickness. There was no evidence of a linear association between thresholding adjustments and biomodel accuracy. Higher measured radiation dose led to a decrease in absolute relative error for biomodel diameter and for 4 of 8 cortical thickness measurements. CONCLUSIONS AND CLINICAL RELEVANCE The outside dimensions of biomodels have a clinically acceptable accuracy. The cortical thickness of biomodels may overestimate cortical thickness. Variability among biomodels was caused by model fabrication reproducibility and, to a lesser extent, by the radiation settings of the CT scan and differences among fabrication methods.

[1]  K D Hopper,et al.  The quality of 3D reconstructions from 1.0 and 1.5 pitch helical and conventional CT. , 1996, Journal of computer assisted tomography.

[2]  Jonathan N Grauer,et al.  Radiation exposure from musculoskeletal computerized tomographic scans. , 2009, The Journal of bone and joint surgery. American volume.

[3]  Nobuhiko Tanaka,et al.  Application of full-scale three-dimensional models in patients with rheumatoid cervical spine , 2008, European Spine Journal.

[4]  J. Y. Choi,et al.  Analysis of errors in medical rapid prototyping models. , 2002, International journal of oral and maxillofacial surgery.

[5]  C. Tseng,et al.  Computer-aided reconstruction of traumatic fronto-orbital osseous defects: aesthetic considerations. , 2004, Chang Gung medical journal.

[6]  O. Harrysson,et al.  Custom-designed orthopedic implants evaluated using finite element analysis of patient-specific computed tomography data: femoral-component case study , 2007, BMC musculoskeletal disorders.

[7]  Alexander L. Wolf,et al.  Software architecture , 2001 .

[8]  J. Chow,et al.  Zygomatic implants--protocol for immediate occlusal loading: a preliminary report. , 2006, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[9]  Stefan Weber,et al.  Stereolithographic models for surgical planning in congenital heart surgery. , 2007, The Annals of thoracic surgery.

[10]  J. Winder,et al.  Medical rapid prototyping technologies: state of the art and current limitations for application in oral and maxillofacial surgery. , 2005, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[11]  Stefano Filippi,et al.  Virtual reality surgical planning for maxillofacial distraction osteogenesis: the role of reverse engineering rapid prototyping and cooperative work. , 2007, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[12]  Paul S D'Urso,et al.  Biomodeling as an Aid to Spinal Instrumentation , 2004, Spine.

[13]  D. Ross,et al.  The rapid prototyping of anatomic models in pulmonary atresia. , 2006, The Journal of thoracic and cardiovascular surgery.

[14]  Ola L. A. Harrysson,et al.  Rapid prototyping for treatment of canine limb deformities , 2003 .

[15]  M E Bastin,et al.  Anatomical flow phantoms of the nonplanar carotid bifurcation, part I: computer-aided design and fabrication. , 2007, Ultrasound in medicine & biology.

[16]  F. Migliavacca,et al.  Use of rapid prototyping models in the planning of percutaneous pulmonary valved stent implantation , 2007, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[17]  R. W. Günther,et al.  Pediatric craniofacial surgery: Comparison of milling and stereolithography for 3D model manufacturing , 2005, Pediatric Radiology.

[18]  Chee Kai Chua,et al.  Rapid Prototyping:Principles and Applications , 2010 .

[19]  K W Dalgarno,et al.  Flexible tubular replicas of abdominal aortic aneurysms , 2002, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[20]  M. Zanetti,et al.  Rapid prototyping (stereolithography) in the management of intra-articular calcaneal fractures , 1997, European Radiology.

[21]  Timothy M. Barker,et al.  Stereolithographic biomodelling in cranio-maxillofacial surgery: A prospective trial , 1999 .

[22]  T M Barker,et al.  Accuracy of stereolithographic models of human anatomy. , 1994, Australasian radiology.

[23]  Paul F. Jacobs,et al.  Rapid Prototyping & Manufacturing: Fundamentals of Stereolithography , 1992 .

[24]  Jorge Vicente Lopes da Silva,et al.  Dimensional error in selective laser sintering and 3D-printing of models for craniomaxillary anatomy reconstruction. , 2008, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[25]  W. Paiva,et al.  Aplication of the stereolithography technique in complex spine surgery. , 2007, Arquivos de neuro-psiquiatria.

[26]  Z Y Zhang,et al.  Reconstruction of a palatomaxillary defect with vascularized iliac bone combined with a superficial inferior epigastric artery flap and zygomatic implants as anchorage. , 2007, International journal of oral and maxillofacial surgery.

[27]  A. Joubert,et al.  Hydroxyapatite-coated polyurethane for auricular cartilage replacement: an in vitro study. , 2008, Journal of biomedical materials research. Part A.

[28]  Xiaohong Wang,et al.  Rapid prototyping as a tool for manufacturing bioartificial livers. , 2007, Trends in biotechnology.

[29]  Volkmar Falk,et al.  3D-Imaging of cardiac structures using 3D heart models for planning in heart surgery: a preliminary study. , 2008, Interactive cardiovascular and thoracic surgery.

[30]  F. Migliavacca,et al.  Percutaneous pulmonary valve implantation based on rapid prototyping of right ventricular outflow tract and pulmonary trunk from MR data. , 2007, Radiology.

[31]  M. Markel,et al.  Histomorphometric analysis of articular cartilage, zone of calcified cartilage, and subchondral bone plate in femoral heads from clinically normal dogs and dogs with moderate or severe osteoarthritis. , 2006, American journal of veterinary research.

[32]  Malcolm N. Cooke,et al.  Use of stereolithography to manufacture critical-sized 3D biodegradable scaffolds for bone ingrowth. , 2003, Journal of biomedical materials research. Part B, Applied biomaterials.

[33]  K. Dai,et al.  Computer-aided custom-made hemipelvic prosthesis used in extensive pelvic lesions. , 2007, The Journal of arthroplasty.

[34]  James H. Torrie,et al.  Principles and procedures of statistics: a biometrical approach (2nd ed) , 1980 .

[35]  Adir Cohen,et al.  Mandibular reconstruction using stereolithographic 3-dimensional printing modeling technology. , 2009, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[36]  D. Silva,et al.  Dimensional error of selective laser sintering, three-dimensional printing and PolyJet models in the reproduction of mandibular anatomy. , 2009, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[37]  Timothy C Ryken,et al.  Rapid prototype patient-specific drill template for cervical pedicle screw placement , 2007, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[38]  Hiroyuki Hiramatsu,et al.  Three-dimensional laryngeal model for planning of laryngeal framework surgery , 2006, Acta oto-laryngologica.

[39]  D. Brenner,et al.  Estimated risks of radiation-induced fatal cancer from pediatric CT. , 2001, AJR. American journal of roentgenology.

[40]  Jeremy Knox,et al.  A Comparison of Plaster, Digital and Reconstructed Study Model Accuracy , 2008, Journal of orthodontics.

[41]  B. Seedhom,et al.  Accuracy of MRI vs CT imaging with particular reference to patient specific templates for total knee replacement surgery , 2008, The international journal of medical robotics + computer assisted surgery : MRCAS.

[42]  Brett A Miles,et al.  Stereolithography for craniofacial surgery. , 2006, The Journal of craniofacial surgery.

[43]  M. Skalicky,et al.  Signalment differences in bone mineral content and bone mineral density in canine appendicular bones , 2008, Veterinary and Comparative Orthopaedics and Traumatology.

[44]  Minna Kellomäki,et al.  A review of rapid prototyping techniques for tissue engineering purposes , 2008, Annals of medicine.

[45]  C. Hurson,et al.  Rapid prototyping in the assessment, classification and preoperative planning of acetabular fractures. , 2007, Injury.

[46]  C. Kerber,et al.  Stereolithographic vascular replicas from CT scans: choosing treatment strategies, teaching, and research from live patient scan data. , 2005, AJNR. American journal of neuroradiology.

[47]  Abhay S Pandit,et al.  Using computed tomography scans to develop an ex-vivo gastric model. , 2007, World journal of gastroenterology.

[48]  Denis J Marcellin-Little,et al.  In vitro evaluation of five canine tibial plateau leveling methods. , 2006, American journal of veterinary research.

[49]  D. Pienkowski,et al.  Bone engineering of the rabbit ulna. , 2007, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.