Parametrically defined cerebral blood vessels as non-invasive blood input functions for brain PET studies.

A non-invasive alternative to arterial blood sampling for the generation of a blood input function for brain positron emission tomography (PET) studies is presented. The method aims to extract the dimensions of the blood vessel directly from PET images and to simultaneously correct the radioactivity concentration for partial volume and spillover. This involves simulation of the tomographic imaging process to generate images of different blood vessel and background geometries and selecting the one that best fits, in a least-squares sense, the acquired PET image. A phantom experiment was conducted to validate the method which was then applied to eight subjects injected with 6-[18F]fluoro-L-DOPA and one subject injected with [11C]CO-labelled red blood cells. In the phantom study, the diameter of syringes filled with an 11C solution and inserted into a water-filled cylinder were estimated with an accuracy of half a pixel (1 mm). The radioactivity concentration was recovered to 100 +/- 4% in the 8.7 mm diameter syringe, the one that most closely approximated the superior sagittal sinus. In the human studies, the method systematically overestimated the calibre of the superior sagittal sinus by 2-3 mm compared to measurements made in magnetic resonance venograms on the same subjects. Sources of discrepancies related to the anatomy of the blood vessel were found not to be fundamental limitations to the applicability of the method to human subjects. This method has the potential to provide accurate quantification of blood radioactivity concentration from PET images without the need for blood samples, corrections for delay and dispersion, co-registered anatomical images, or manually defined regions of interest.

[1]  Charles C. Watson,et al.  ECAT ART — a continuously rotating PET camera: Performance characteristics, initial clinical studies, and installation considerations in a nuclear medicine department , 2005, European Journal of Nuclear Medicine.

[2]  I Kanno,et al.  Noninvasive quantitation of cerebral blood flow using oxygen-15-water and a dual-PET system. , 1998, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[3]  A. Lammertsma,et al.  Use of the left ventricular time-activity curve as a noninvasive input function in dynamic oxygen-15-water positron emission tomography. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[4]  F. Miraldi,et al.  Noninvasive arterial monitor for quantitative oxygen-15-water blood flow studies. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[5]  P Van Tassel,et al.  Normal and variant anatomy of the dural venous sinuses. , 1994, Seminars in ultrasound, CT, and MR.

[6]  Klaus Wienhard,et al.  The ECAT HRRT: performance and first clinical application of the new high resolution research tomograph , 2000 .

[7]  A. Evans,et al.  Correction for partial volume effects in PET: principle and validation. , 1998, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[8]  D Saloner,et al.  Artifacts associated with MR neuroangiography. , 1992, AJNR. American journal of neuroradiology.

[9]  E. Hoffman,et al.  Use of the abdominal aorta for arterial input function determination in hepatic and renal PET studies. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[10]  J. Correia A bloody future for clinical PET? , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[11]  Vincent J Cunningham,et al.  In vivo metabolism and partitioning of 6-[18F]fluoro-L-meta-tyrosine in whole blood: a unified compartment model. , 2002, Physics in medicine and biology.

[12]  R. Kessler,et al.  Analysis of emission tomographic scan data: limitations imposed by resolution and background. , 1984, Journal of computer assisted tomography.

[13]  Roger Fulton,et al.  The design and implementation of a motion correction scheme for neurological PET. , 2003, Physics in medicine and biology.

[14]  A. Keats,et al.  On the Safety of Radial Artery Cannulation , 1983 .

[15]  J J DiStefano,et al.  Multiexponential, multicompartmental, and noncompartmental modeling. II. Data analysis and statistical considerations. , 1984, The American journal of physiology.

[16]  Lindi M. Wahl,et al.  Venous Sinuses vs. On-Line Arterial Sampling as Input Functions in PET , 2000 .

[17]  D. Feng,et al.  Noninvasive Quantification of the Cerebral Metabolic Rate for Glucose Using Positron Emission Tomography, 18F-Fluoro-2-Deoxyglucose, the Patlak Method, and an Image-Derived Input Function , 1998, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[18]  L. Adler,et al.  Simultaneous recovery of size and radioactivity concentration of small spheroids with PET data. , 1999, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[19]  J C Froment,et al.  Positron Emission Tomography Metabolic Data Corrected for Cortical Atrophy Using Magnetic Resonance Imaging , 1996, Alzheimer disease and associated disorders.

[20]  J. Litton,et al.  Input function in PET brain studies using MR-defined arteries. , 1997, Journal of computer assisted tomography.

[21]  C Nahmias,et al.  Single-photon transmission measurements in positron tomography using 137Cs. , 1995, Physics in medicine and biology.

[22]  Paul Kinahan,et al.  Analytic 3D image reconstruction using all detected events , 1989 .

[23]  E. Hoffman,et al.  Tomographic measurement of local cerebral glucose metabolic rate in humans with (F‐18)2‐fluoro‐2‐deoxy‐D‐glucose: Validation of method , 1979, Annals of neurology.

[24]  C Nahmias,et al.  Regions of interest in the venous sinuses as input functions for quantitative PET. , 1999, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[25]  Richard E. Carson,et al.  Noise characteristics of 3-D and 2-D PET images , 1998, IEEE Transactions on Medical Imaging.

[26]  G. Gullberg,et al.  Blind estimation of compartmental model parameters. , 1999, Physics in medicine and biology.

[27]  Alan C. Evans,et al.  Positron Emission Tomography Partial Volume Correction: Estimation and Algorithms , 2002, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[28]  D. Newport,et al.  A Single Scatter Simulation Technique for Scatter Correction in 3D PET , 1996 .

[29]  J. Holden,et al.  Quantitation of Local Cerebral Blood Flow and Partition Coefficient without Arterial Sampling: Theory and Validation , 1985, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[30]  Peter Herscovitch,et al.  Comparison of Bolus and Infusion Methods for Receptor Quantitation: Application to [18F]Cyclofoxy and Positron Emission Tomography , 1993, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[31]  D Eidelberg,et al.  Quantitative brain FDG/PET studies using dynamic aortic imaging. , 1994, Physics in medicine and biology.

[32]  M E Phelps,et al.  Derivation of input function from FDG-PET studies in small hearts. , 1996, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[33]  Vincent J. Cunningham,et al.  Parametric Imaging of Ligand-Receptor Binding in PET Using a Simplified Reference Region Model , 1997, NeuroImage.

[34]  Karl J. Friston,et al.  MRI and PET Coregistration—A Cross Validation of Statistical Parametric Mapping and Automated Image Registration , 1997, NeuroImage.

[35]  I Kanno,et al.  Blood sampling devices and measurements. , 1991, Medical progress through technology.

[36]  Cyril Riddell,et al.  Noninvasive estimation of the aorta input function for measurement of tumor blood flow with [/sup 15/O] water , 2001, IEEE Transactions on Medical Imaging.

[37]  V. Dhawan,et al.  Noninvasive quantitative fluorodeoxyglucose PET studies with an estimated input function derived from a population-based arterial blood curve. , 1993, Radiology.

[38]  S. Osman,et al.  On-line measurement of exhaled [11C]CO2 during PET. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[39]  E. Hoffman,et al.  Quantitation in Positron Emission Computed Tomography: 1. Effect of Object Size , 1979, Journal of computer assisted tomography.

[40]  T. Zeffiro,et al.  Head movement in normal subjects during simulated PET brain imaging with and without head restraint. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[41]  M. Dujovny,et al.  Microsurgical anatomy of the venous drainage into the superior sagittal sinus. , 1989 .

[42]  C. C. Watson New, faster, image-based scatter correction for 3D PET , 1999 .

[43]  D. Newport,et al.  Evaluation of simulation-based scatter correction for 3-D PET cardiac imaging , 1995 .

[44]  D Strul,et al.  Robustness of Anatomically Guided Pixel-by-Pixel Algorithms for Partial Volume Effect Correction in Positron Emission Tomography , 1999, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[45]  D J Brooks,et al.  Comparison of Methods for Analysis of Clinical [11C]Raclopride Studies , 1996, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.