How does blood oxygen level‐dependent (BOLD) contrast correlate with oxygen partial pressure (pO2) inside tumors?

Blood oxygen level‐dependent (BOLD) contrast‐based functional MRI (fMRI) has been reported as a method to assess the evolution of tumor oxygenation after hyperoxic treatments, because of its sensitivity to changes in blood flow and deoxyhemoglobin content. However a number of questions remain: 1) In view of tumor heterogeneity, how good is the correlation between the MR parameters in gradient‐echo imaging (signal intensity (SI) or effective transverse relaxation time (T  *2 )) and local tumor oxygen partial pressure (pO2)? 2) Is the magnitude of the change in SI or T  *2 a quantitative marker for variation in pO2? 3) Is initial T  *2 a good marker for initial pO2? To address these questions, murine tumors were imaged during respiratory challenges at 4.7 Tesla, using fiber‐optic microprobes to simultaneously acquire tumor pO2 and erythrocyte flux. The BOLD signal response (SI and T  *2 ) was temporally correlated with changes in pO2. However, the magnitude of the signal bore no absolute relation to pO2 across tumors, i.e., a given change in SI corresponded to a 25 mmHg pO2 change in one tumor, but to a 100 mmHg change in another. The initial T  *2 value did not reliably predict tumor oxygenation at the beginning of the experiment. In conclusion, the major advantages of the technique include noninvasiveness, high spatial resolution, and real‐time detection of pO2 fluctuations. Information afforded by the BOLD imaging technique is qualitative in nature and may be combined with other techniques capable of providing an absolute measure of pO2. Magn Reson Med 48:980–986, 2002. © 2002 Wiley‐Liss, Inc.

[1]  S. Vijayakumar,et al.  Effects of hyperoxia on T  2* and resonance frequency weighted magnetic resonance images of rodent tumours , 1994, NMR in biomedicine.

[2]  S. Ogawa,et al.  Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields , 1990, Magnetic resonance in medicine.

[3]  F. Howe,et al.  Noninvasive monitoring of carbogen-induced changes in tumor blood flow and oxygenation by functional magnetic resonance imaging. , 1995, International journal of radiation oncology, biology, physics.

[4]  R. M. Weisskoff,et al.  Basic Theoretical Models of BOLD Signal Change , 2000 .

[5]  M Diemling,et al.  Quantification of signal changes in gradient recalled echo FMRI. , 1997, Magnetic resonance imaging.

[6]  P. Misson,et al.  Pharmacological modifications of the partial pressure of oxygen in murine tumors: Evaluation using in vivo EPR oximetry , 1999, Magnetic resonance in medicine.

[7]  E. Rofstad,et al.  Intratumour heterogeneity in microvessel oxyhaemoglobin saturations. , 2001, Cancer letters.

[8]  J. Dunn,et al.  Blood oxygenation. Heterogeneity of hypoxic tissues monitored using bold MR imaging. , 1997, Advances in experimental medicine and biology.

[9]  G. Radda,et al.  Oxygenation dependence of the transverse relaxation time of water protons in whole blood at high field. , 1982, Biochimica et biophysica acta.

[10]  G S Karczmar,et al.  Correlation of magnetic resonance and oxygen microelectrode measurements of carbogen-induced changes in tumor oxygenation. , 1998, International journal of radiation oncology, biology, physics.

[11]  Peter Vaupel,et al.  Blood Perfusion and Microenvironment of Human Tumors , 2000 .

[12]  L Weissfloch,et al.  Oxygen-induced MR signal changes in murine tumors. , 1998, Magnetic resonance imaging.

[13]  L. H. Gray,et al.  The Histological Structure of Some Human Lung Cancers and the Possible Implications for Radiotherapy , 1955, British Journal of Cancer.

[14]  Risto A. Kauppinen,et al.  Quantitative assessment of blood flow, blood volume and blood oxygenation effects in functional magnetic resonance imaging , 1998, Nature Medicine.

[15]  M. Molls,et al.  The Impact of the Tumor Microenvironment on Experimental and Clinical Radiation Oncology and Other Therapeutic Modalities , 2000 .

[16]  Y. Wang,et al.  Blood oxygen saturation assessment in vivo using T2 * estimation , 1998, Magnetic resonance in medicine.

[17]  J R Griffiths,et al.  Issues in flow and oxygenation dependent contrast (FLOOD) imaging of tumours , 2001, NMR in biomedicine.

[18]  B. Fenton,et al.  Quantification of micro-regional heterogeneities in tumor oxygenation using intravascular HbO2 saturations. , 1995, Radiation research.

[19]  Ravi S. Menon,et al.  Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. A comparison of signal characteristics with a biophysical model. , 1993, Biophysical journal.

[20]  Song Lai,et al.  Spatial Selectivity of BOLD Contrast: Effects In and Around Draining Veins , 2000 .

[21]  R R Edelman,et al.  Noninvasive evaluation of intrarenal oxygenation with BOLD MRI. , 1996, Circulation.

[22]  J R Griffiths,et al.  The response of human tumors to carbogen breathing, monitored by Gradient-Recalled Echo Magnetic Resonance Imaging. , 1997, International journal of radiation oncology, biology, physics.

[23]  R. Demeure,et al.  Changes in tumor oxygenation/perfusion induced by the no donor, isosorbide dinitrate, in comparison with carbogen: monitoring by EPR and MRI. , 2000, International journal of radiation oncology, biology, physics.

[24]  R G Spencer,et al.  Electron paramagnetic resonance oxygen mapping (EPROM): Direct visualization of oxygen concentration in tissue , 2000, Magnetic resonance in medicine.

[25]  P. Carlier,et al.  Simultaneous measurement of perfusion and oxygenation changes using a multiple gradient-echo sequence: application to human muscle study. , 1998, Magnetic resonance imaging.

[26]  P. Antich,et al.  Tumor oximetry: demonstration of an enhanced dynamic mapping procedure using fluorine-19 echo planar magnetic resonance imaging in the Dunning prostate R3327-AT1 rat tumor. , 2001, International journal of radiation oncology, biology, physics.

[27]  H. Withers,et al.  Immunological resistance to pulmonary metastases in C3Hf-Bu mice bearing syngeneic fibrosarcoma of different sizes. , 1974, Cancer research.

[28]  J R Griffiths,et al.  Flow and oxygenation dependent (FLOOD) contrast MR imaging to monitor the response of rat tumors to carbogen breathing. , 1999, Magnetic resonance imaging.

[29]  E M Haacke,et al.  Predicting BOLD signal changes as a function of blood volume fraction and resolution , 2001, NMR in biomedicine.

[30]  H. Swartz,et al.  The measurement of oxygen in vivo using EPR techniques. , 1998, Physics in medicine and biology.

[31]  J R Griffiths,et al.  The OxyLite: a fibre-optic oxygen sensor. , 1999, The British journal of radiology.

[32]  Kecheng Liu,et al.  Dynamic in vivo oxymetry using overhauser enhanced MR imaging , 2000, Journal of magnetic resonance imaging : JMRI.