Monte Carlo simulations of a nozzle for the treatment of ocular tumours with high-energy proton beams

By the end of 2002, 33 398 patients worldwide had been treated with proton radiotherapy, 10 829 for eye diseases. The dose prediction algorithms used today for ocular proton therapy treatment planning rely on parameterizations of measured proton dose distributions, i.e., broad-beam and pencil-beam techniques, whose predictive capabilities are inherently limited by severe approximations and simplifications in modelling the radiation transport physics. In contrast, the Monte Carlo radiation transport technique can, in principle, provide accurate predictions of the proton treatment beams by taking into account all the physical processes involved, including coulombic energy loss, energy straggling, multiple Coulomb scattering, elastic and nonelastic nuclear interactions, and the transport of secondary particles. It has not been shown, however, whether it is possible to commission a proton treatment planning system by using data exclusively from Monte Carlo simulations of the treatment apparatus and a phantom. In this work, we made benchmark comparisons between Monte Carlo predictions and measurements of an ocular proton treatment beamline. The maximum differences between absorbed dose profiles from simulations and measurements were 6% and 0.6 mm, while typical differences were less than 2% and 0.2 mm. The computation time for the entire virtual commissioning process is less than one day. The study revealed that, after a significant development effort, a Monte Carlo model of a proton therapy apparatus is sufficiently accurate and fast for commissioning a treatment planning system.

[1]  Proton beam dosimetry for radiosurgery: implementation of the ICRU Report 59 at the Harvard Cyclotron Laboratory. , 2002, Physics in medicine and biology.

[2]  T. Sakae,et al.  Multi-layer energy filter for realizing conformal irradiation in charged particle therapy. , 2000, Medical physics.

[3]  P Andreo,et al.  Monte Carlo calculated stopping-power ratios, water/air, for clinical proton dosimetry (50-250 MeV). , 1997, Physics in medicine and biology.

[4]  Uwe Titt,et al.  Neutron shielding verification measurements and simulations for a 235-MeV proton therapy center , 2002 .

[5]  H Paganetti,et al.  Nuclear interactions of 160 MeV protons stopping in copper: a test of Monte Carlo nuclear models. , 1999, Medical physics.

[6]  U. Titt,et al.  Neutron shielding calculations in a proton therapy facility based on Monte Carlo simulations and analytical models: criterion for selecting the method of choice. , 2005, Radiation protection dosimetry.

[7]  S Agosteo,et al.  Secondary neutron and photon dose in proton therapy. , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[8]  E. Gragoudas,et al.  Proton beam therapy for age-related macular degeneration: development of a standard plan. , 1999, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[9]  K. C. Chandler,et al.  SPAR, a FORTRAN program for computing stopping powers and ranges for muons, charged pions, protons, and heavy ions , 1973 .

[10]  M. Fippel,et al.  A Monte Carlo dose calculation algorithm for proton therapy. , 2004, Medical physics.

[11]  W. Newhauser,et al.  Calculations of neutron dose equivalent exposures from range-modulated proton therapy beams , 2005, Physics in medicine and biology.

[12]  Anatoly B Rosenfeld,et al.  The role of nonelastic reactions in absorbed dose distributions from therapeutic proton beams in different medium. , 2004, Medical physics.

[13]  B. Rossi,et al.  Cosmic-Ray Theory , 1941 .

[14]  Stallard Hb,et al.  Malignant melanoblastoma of the choroid. , 1968 .

[15]  H. G. Hughes,et al.  Cross-Section Evaluations to 150 MeV for Accelerator-Driven Systems and Implementation in MCNPX , 1999 .

[16]  F. Verhaegen,et al.  A systematic Monte Carlo study of secondary electron fluence perturbation in clinical proton beams (70-250 MeV) for cylindrical and spherical ion chambers. , 2001, Medical physics.

[17]  H. Paganetti Calculation of the spatial variation of relative biological effectiveness in a therapeutic proton field for eye treatment. , 1998, Physics in medicine and biology.

[18]  Dan T. L. Jones,et al.  Fluence correction factors in plastic phantoms for clinical proton beams. , 2002, Physics in medicine and biology.

[19]  U Titt,et al.  Therapeutic step and shoot proton beam spot-scanning with a multi-leaf collimator: a Monte Carlo study. , 2005, Radiation protection dosimetry.

[20]  F. Mourtada,et al.  106Ru/106Rh plaque and proton radiotherapy for ocular melanoma: a comparative dosimetric study. , 2005, Radiation protection dosimetry.

[21]  L. Verhey,et al.  Conservative treatment of uveal melanoma: local recurrence after proton beam therapy. , 1989, International journal of radiation oncology, biology, physics.

[22]  U. Titt,et al.  Patient neutron dose equivalent exposures outside of the proton therapy treatment field. , 2005, Radiation protection dosimetry.

[23]  P Chauvel,et al.  Monte Carlo simulation of a protontherapy platform devoted to ocular melanoma. , 2005, Medical physics.

[24]  M Goitein,et al.  A pencil beam algorithm for proton dose calculations. , 1996, Physics in medicine and biology.

[25]  A. Koehler,et al.  Measurement of neutron dose equivalent to proton therapy patients outside of the proton radiation field , 2002 .

[26]  H Paganetti,et al.  Monte Carlo method to study the proton fluence for treatment planning. , 1998, Medical physics.

[27]  R. Wilson Radiological use of fast protons. , 1946, Radiology.

[28]  U. Oelfke,et al.  Two-dimensional pencil beam scaling: an improved proton dose algorithm for heterogeneous media. , 2002, Physics in medicine and biology.

[29]  M Goitein,et al.  Planning proton therapy of the eye. , 1983, Medical physics.

[30]  M Gambaccini,et al.  Dual-energy tissue cancellation in mammography with quasi-monochromatic x-rays. , 2002, Physics in medicine and biology.

[31]  H Paganetti,et al.  Adaptation of GEANT4 to Monte Carlo dose calculations based on CT data. , 2004, Medical physics.

[32]  U Isacsson,et al.  Implementation of pencil kernel and depth penetration algorithms for treatment planning of proton beams. , 2000, Physics in medicine and biology.

[33]  E Pedroni,et al.  Monte Carlo dose calculations for spot scanned proton therapy , 2005, Physics in medicine and biology.

[34]  Harald Paganetti,et al.  Monte Carlo simulations with time-dependent geometries to investigate effects of organ motion with high temporal resolution. , 2004, International journal of radiation oncology, biology, physics.

[35]  W. Newhauser,et al.  Virtual commissioning of a treatment planning system for proton therapy of ocular cancers. , 2005, Radiation protection dosimetry.

[36]  E. Pedroni,et al.  Dose calculation models for proton treatment planning using a dynamic beam delivery system: an attempt to include density heterogeneity effects in the analytical dose calculation. , 1999, Physics in medicine and biology.

[37]  Ann Schalenbourg,et al.  Eye retention after proton beam radiotherapy for uveal melanoma. , 2003, International journal of radiation oncology, biology, physics.

[38]  M Goitein,et al.  Proton beam penumbra: effects of separation between patient and beam modifying devices. , 1986, Medical physics.

[39]  P. V. Vavilov IONIZATION LOSSES OF HIGH-ENERGY HEAVY PARTICLES , 1957 .

[40]  Tianfang Li,et al.  Density resolution of proton computed tomography. , 2005, Medical physics.

[41]  H Paganetti,et al.  Accurate Monte Carlo simulations for nozzle design, commissioning and quality assurance for a proton radiation therapy facility. , 2004, Medical physics.

[42]  F. Verhaegen,et al.  Dosimetry using plane-parallel ionization chambers in a 75 MeV clinical proton beam. , 2002, Physics in medicine and biology.

[43]  E. Gragoudas,et al.  Uveal melanoma: proton beam irradiation. , 2005, Ophthalmology clinics of North America.

[44]  H. Kubo,et al.  Patient positioning for protontherapy using a proton range telescope , 1995 .

[45]  E. Pedroni,et al.  Secondary neutron dose during proton therapy using spot scanning. , 2002, International journal of radiation oncology, biology, physics.

[46]  I J Constable,et al.  Experimental ocular irradiation with accelerated protons. , 1974, Investigative ophthalmology.

[47]  Design tools for proton therapy nozzles based on the double-scattering foil technique. , 2005, Radiation protection dosimetry.