Performance evaluation of automatic anatomy segmentation algorithm on repeat or four-dimensional computed tomography images using deformable image registration method.

PURPOSE Auto-propagation of anatomic regions of interest from the planning computed tomography (CT) scan to the daily CT is an essential step in image-guided adaptive radiotherapy. The goal of this study was to quantitatively evaluate the performance of the algorithm in typical clinical applications. METHODS AND MATERIALS We had previously adopted an image intensity-based deformable registration algorithm to find the correspondence between two images. In the present study, the regions of interest delineated on the planning CT image were mapped onto daily CT or four-dimensional CT images using the same transformation. Postprocessing methods, such as boundary smoothing and modification, were used to enhance the robustness of the algorithm. Auto-propagated contours for 8 head-and-neck cancer patients with a total of 100 repeat CT scans, 1 prostate patient with 24 repeat CT scans, and 9 lung cancer patients with a total of 90 four-dimensional CT images were evaluated against physician-drawn contours and physician-modified deformed contours using the volume overlap index and mean absolute surface-to-surface distance. RESULTS The deformed contours were reasonably well matched with the daily anatomy on the repeat CT images. The volume overlap index and mean absolute surface-to-surface distance was 83% and 1.3 mm, respectively, compared with the independently drawn contours. Better agreement (>97% and <0.4 mm) was achieved if the physician was only asked to correct the deformed contours. The algorithm was also robust in the presence of random noise in the image. CONCLUSION The deformable algorithm might be an effective method to propagate the planning regions of interest to subsequent CT images of changed anatomy, although a final review by physicians is highly recommended.

[1]  K. Brock,et al.  Accuracy of finite element model-based multi-organ deformable image registration. , 2005, Medical physics.

[2]  P. Keall 4-dimensional computed tomography imaging and treatment planning. , 2004, Seminars in radiation oncology.

[3]  Tiezhi Zhang,et al.  On the automated definition of mobile target volumes from 4D-CT images for stereotactic body radiotherapy. , 2005, Medical physics.

[4]  George T. Y. Chen,et al.  Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion. , 2005, International journal of radiation oncology, biology, physics.

[5]  He Wang,et al.  An automatic CT-guided adaptive radiation therapy technique by online modification of multileaf collimator leaf positions for prostate cancer. , 2005, International journal of radiation oncology, biology, physics.

[6]  F. Yin,et al.  Reduction of organ motion by combined cardiac gating and respiratory gating. , 2007, International journal of radiation oncology, biology, physics.

[7]  Suresh Senan,et al.  Benefit of respiration-gated stereotactic radiotherapy for stage I lung cancer: an analysis of 4DCT datasets. , 2005, International journal of radiation oncology, biology, physics.

[8]  M van Herk,et al.  Definition of the prostate in CT and MRI: a multi-observer study. , 1999, International journal of radiation oncology, biology, physics.

[9]  Patrick A Kupelian,et al.  Evaluation of image-guidance protocols in the treatment of head and neck cancers. , 2007, International journal of radiation oncology, biology, physics.

[10]  Lei Dong,et al.  Automatic registration of the prostate for computed-tomography-guided radiotherapy. , 2003, Medical physics.

[11]  Vladimir Pekar,et al.  Automated model-based organ delineation for radiotherapy planning in prostatic region. , 2004, International journal of radiation oncology, biology, physics.

[12]  G S Bauman,et al.  Tracking the dose distribution in radiation therapy by accounting for variable anatomy , 2004, Physics in medicine and biology.

[13]  Joe Y. Chang,et al.  Validation of an accelerated ‘demons’ algorithm for deformable image registration in radiation therapy , 2005, Physics in medicine and biology.

[14]  He Wang,et al.  Use of deformed intensity distributions for on-line modification of image-guided IMRT to account for interfractional anatomic changes. , 2005, International journal of radiation oncology, biology, physics.

[15]  Di Yan,et al.  Automatic delineation of on-line head-and-neck computed tomography images: toward on-line adaptive radiotherapy. , 2007, International journal of radiation oncology, biology, physics.

[16]  Radhe Mohan,et al.  A fast dose calculation method based on table lookup for IMRT optimization. , 2003, Physics in medicine and biology.

[17]  D. Yan,et al.  A model to accumulate fractionated dose in a deforming organ. , 1999, International journal of radiation oncology, biology, physics.

[18]  A Neumann,et al.  Statistical shape model based segmentation of medical images. , 1998, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[19]  Quan Chen,et al.  Automatic re-contouring in 4D radiotherapy , 2006, Physics in medicine and biology.

[20]  Cedric X. Yu,et al.  Guidance document on delivery, treatment planning, and clinical implementation of IMRT: report of the IMRT Subcommittee of the AAPM Radiation Therapy Committee. , 2003, Medical physics.

[21]  Brian O'Sullivan,et al.  Intraobserver and interobserver variability in GTV delineation on FDG-PET-CT images of head and neck cancers. , 2007, International journal of radiation oncology, biology, physics.

[22]  John Wong,et al.  A dose-escalation trial with the adaptive radiotherapy process as a delivery system in localized prostate cancer: analysis of chronic toxicity. , 2005, International journal of radiation oncology, biology, physics.

[23]  Lei Dong,et al.  Evaluation of a contour-alignment technique for CT-guided prostate radiotherapy: an intra- and interobserver study. , 2004, International journal of radiation oncology, biology, physics.

[24]  Radhe Mohan,et al.  A deformable image registration method to handle distended rectums in prostate cancer radiotherapy. , 2006, Medical physics.

[25]  D. Yan,et al.  The influence of interpatient and intrapatient rectum variation on external beam treatment of prostate cancer. , 2001, International journal of radiation oncology, biology, physics.

[26]  Radhe Mohan,et al.  Implementation and validation of a three-dimensional deformable registration algorithm for targeted prostate cancer radiotherapy. , 2004, International journal of radiation oncology, biology, physics.

[27]  G C Sharp,et al.  GPU-based streaming architectures for fast cone-beam CT image reconstruction and demons deformable registration , 2007, Physics in medicine and biology.

[28]  M. V. van Herk,et al.  A model to simulate day-to-day variations in rectum shape. , 2002, International journal of radiation oncology, biology, physics.

[29]  J. Fowler,et al.  Image guidance for precise conformal radiotherapy. , 2003, International journal of radiation oncology, biology, physics.

[30]  D. Yan,et al.  Computed tomography guided management of interfractional patient variation. , 2005, Seminars in radiation oncology.

[31]  Radhe Mohan,et al.  Evaluation of mechanical precision and alignment uncertainties for an integrated CT/LINAC system. , 2003, Medical physics.

[32]  Raj Shekhar,et al.  Automatic segmentation of phase-correlated CT scans through nonrigid image registration using geometrically regularized free-form deformation. , 2007, Medical physics.

[33]  David A Jaffray,et al.  Cone-beam computed tomography for on-line image guidance of lung stereotactic radiotherapy: localization, verification, and intrafraction tumor position. , 2007, International journal of radiation oncology, biology, physics.

[34]  Jean-François Daisne,et al.  Inter-observer variability in the delineation of pharyngo-laryngeal tumor, parotid glands and cervical spinal cord: comparison between CT-scan and MRI. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[35]  C. Raaijmakers,et al.  Interobserver variability of clinical target volume delineation of glandular breast tissue and of boost volume in tangential breast irradiation. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[36]  Dinggang Shen,et al.  Segmentation of prostate boundaries from ultrasound images using statistical shape model , 2003, IEEE Transactions on Medical Imaging.

[37]  Radhe Mohan,et al.  Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT/linear accelerator system. , 2004, International journal of radiation oncology, biology, physics.

[38]  J. Wong,et al.  Flat-panel cone-beam computed tomography for image-guided radiation therapy. , 2002, International journal of radiation oncology, biology, physics.

[39]  Yueh-Yun Chi,et al.  Comparison of human and automatic segmentations of kidneys from CT images. , 2005, International journal of radiation oncology, biology, physics.

[40]  Ion-Florin Talos,et al.  Statistical validation of brain tumor shape approximation via spherical harmonics for image-guided neurosurgery. , 2005, Academic radiology.