In vivo human tendon mechanical properties

1 The aim of the present study was to measure the mechanical properties of human tibialis anterior (TA) tendon in vivo. 2 Measurements were taken in five males at the neutral ankle position and involved: (a) isometric dynamometry upon increasing the voltage of percutaneous electrical stimulation of the TA muscle, (b) real‐time ultrasonography for measurements of the TA tendon origin displacement during contraction and tendon cross‐sectional area, and (c) magnetic resonance imaging for estimation of the TA tendon length and moment arm. 3 From the measured joint moments and estimated moment arms, the values of tendon force were calculated and divided by cross‐sectional area to obtain stress values. The displacements of the TA tendon origin from rest to all contraction intensities were normalized to tendon length to obtain strain values. From the data obtained, the tendon force‐displacement and stress‐strain relationships were determined and the tendon stiffness and Young's modulus were calculated. 4 Tendon force and stress increased curvilinearly as a function of displacement and strain, respectively. The tendon force and displacement at maximum isometric load were 530 N and 4·1 mm, and the corresponding stress and strain values were 25 MPa and 2·5%, respectively. The tendon stiffness and Young's modulus at maximum isometric load were 161 N mm−1 and 1·2 GPa, respectively. These results are in agreement with previous reports on in vitro testing of isolated tendons and suggest that under physiological loading the TA tendon operates within the elastic ‘toe’ region.

[1]  R. Hall,et al.  Relationship of Muscle Apolipoprotein E Expression with Markers of Cellular Stress, Metabolism, and Blood Biomarkers in Cognitively Healthy and Impaired Older Adults , 2023, Journal of Alzheimer's disease : JAD.

[2]  L. S. Matthews,et al.  Viscoelastic properties of cat tendon: effects of time after death and preservation by freezing. , 1968, Journal of biomechanics.

[3]  V. T. Inman,et al.  Anthropometric studies of the human foot and ankle , 1969 .

[4]  A. Viidik Functional properties of collagenous tissues. , 1973, International review of connective tissue research.

[5]  D. Morgan Separation of active and passive components of short-range stiffness of muscle. , 1977, The American journal of physiology.

[6]  F. Noyes,et al.  BIOMECHANICS OF LIGAMENTS AND TENDONS , 1978, Exercise and sport sciences reviews.

[7]  G. Moskowitz,et al.  Passive and active components of the internal moment developed about the ankle joint during human ambulation. , 1984, Journal of biomechanics.

[8]  P. Rack,et al.  The tendon of flexor pollicis longus: its effects on the muscular control of force and position at the human thumb. , 1984, The Journal of physiology.

[9]  Adaptation of mechanical properties of muscle to high force training in man. , 1985, The Journal of physiology.

[10]  G S Beaupré,et al.  Epiphyseal-based designs for tibial plateau components--II. Stress analysis in the sagittal plane. , 1986, Journal of biomechanics.

[11]  R. F. Ker,et al.  Mechanical properties of various mammalian tendons , 1986 .

[12]  R. Hutton,et al.  Was Sherrington right about co-contractions? , 1986, Brain Research.

[13]  R. F. Ker,et al.  Why are mammalian tendons so thick , 1988 .

[14]  R. M. Alexander,et al.  Elastic mechanisms in animal movement , 1988 .

[15]  B. Fornage Ultrasonography of Muscles and Tendons: Examination Technique and Atlas of Normal Anatomy of the Extremities , 1988 .

[16]  F. Zajac Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control. , 1989, Critical reviews in biomedical engineering.

[17]  R. Lieber,et al.  Frog semitendinosis tendon load-strain and stress-strain properties during passive loading. , 1991, The American journal of physiology.

[18]  V. Edgerton,et al.  Physiological cross‐sectional area of human leg muscles based on magnetic resonance imaging , 1992, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[19]  R L Lieber,et al.  Tendon biomechanical properties enhance human wrist muscle specialization. , 1995, Journal of biomechanics.

[20]  T Fukunaga,et al.  Tendinous movement of a human muscle during voluntary contractions determined by real-time ultrasonography. , 1996, Journal of applied physiology.

[21]  I. S. Young,et al.  Mechanical properties of tendons: changes with sterilization and preservation. , 1996, Journal of biomechanical engineering.

[22]  C. Maganaris,et al.  Changes in Achilles tendon moment arm from rest to maximum isometric plantarflexion: in vivo observations in man , 1998, The Journal of physiology.

[23]  A J Sargeant,et al.  Differences in human antagonistic ankle dorsiflexor coactivation between legs; can they explain the moment deficit in the weaker plantarflexor leg? , 1998, Experimental physiology.

[24]  T Fukunaga,et al.  Nonisometric behavior of fascicles during isometric contractions of a human muscle. , 1998, Journal of applied physiology.

[25]  Vasilios Baltzopoulos,et al.  Predictability of in vivo changes in pennation angle of human tibialis anterior muscle from rest to maximum isometric dorsiflexion , 1999, European Journal of Applied Physiology and Occupational Physiology.

[26]  A J Sargeant,et al.  Changes in the tibialis anterior tendon moment arm from rest to maximum isometric dorsiflexion: in vivo observations in man. , 1999, Clinical biomechanics.