Scan quality effect on glaucoma discrimination by glaucoma imaging devices

Aim: To evaluate, within ocular imaging scans of acceptable quality as determined by manufacturers’ guidelines, the effects of image quality on glaucoma discrimination capabilities. Methods: One hundred and four healthy and 75 glaucomatous eyes from the Advanced Imaging in Glaucoma Study (AIGS) were imaged with GDx-VCC, HRT II and StratusOCT. Quality score (QS⩾8), pixel standard deviation (SD⩽50) and signal strength (SS⩾5) were used as quality parameter cut-offs, respectively. GDx nerve fibre indicator (NFI) and HRT Moorfields regression analysis (MRA) classifications and OCT mean retinal nerve fibre layer (RNFL) thickness were used as the discriminatory parameters. Logistic regression models were used to model the dichotomous clinical classification (healthy vs glaucoma) as a function of image-quality parameters and discriminatory parameters. Results: Quality parameter covariates were statistically non-significant for GDx and HRT but had an inverse effect on OCT in predicting disease (a higher SS had a lower probability of glaucoma). Age was a significant covariate for GDx and HRT, but not OCT, while ethnicity and interaction between the image quality and the institute where scans were acquired were significant covariates in the OCT models. Conclusion: Scan quality within the range recommended as acceptable by the manufacturer of each imaging device does not affect the glaucoma discriminating ability of GDx or HRT but does affect Stratus OCT glaucoma discrimination.

[1]  G. Wollstein,et al.  Comparison of parameters from Heidelberg Retina Tomographs 2 and 3. , 2008, Ophthalmology.

[2]  David R. Anderson,et al.  Model selection and multimodel inference : a practical information-theoretic approach , 2003 .

[3]  J G Fujimoto,et al.  A new quality assessment parameter for optical coherence tomography , 2006, British Journal of Ophthalmology.

[4]  D. Cook,et al.  Variations in primary open-angle glaucoma prevalence by age, gender, and race: a Bayesian meta-analysis. , 2006, Investigative ophthalmology & visual science.

[5]  R. Costa,et al.  Evaluation of image artifact produced by optical coherence tomography of retinal pathology. , 2005, American journal of ophthalmology.

[6]  Hans G Lemij,et al.  Diagnostic accuracy of the GDx VCC for glaucoma. , 2004, Ophthalmology.

[7]  S. Miglior,et al.  Risk factors for glaucoma onset and progression. , 2008, Survey of ophthalmology.

[8]  Parul Sony,et al.  Diagnostic capability of optical coherence tomography in evaluating the degree of glaucomatous retinal nerve fiber damage. , 2006, Investigative ophthalmology & visual science.

[9]  A. Iwase,et al.  Risk factors for open-angle glaucoma in a Japanese population: the Tajimi Study. , 2006, Ophthalmology.

[10]  H. Akaike A new look at the statistical model identification , 1974 .

[11]  L. Labree,et al.  Errors in retinal thickness measurements obtained by optical coherence tomography. , 2006, Ophthalmology.

[12]  M. C. Leske,et al.  Risk factors for incident open-angle glaucoma: the Barbados Eye Studies. , 2008, Ophthalmology.

[13]  H. Taylor,et al.  Risk factors associated with the incidence of open-angle glaucoma: the visual impairment project. , 2003, Investigative ophthalmology & visual science.

[14]  Ki Ho Park,et al.  Diagnostic ability of optical coherence tomography with a normative database to detect localized retinal nerve fiber layer defects. , 2005, Ophthalmology.

[15]  Mauro Vavassori,et al.  Detection of glaucomatous visual field changes using the Moorfields regression analysis of the Heidelberg retina tomograph. , 2003, American journal of ophthalmology.

[16]  F. Medeiros,et al.  Influence of disease severity and optic disc size on the diagnostic performance of imaging instruments in glaucoma. , 2006, Investigative ophthalmology & visual science.

[17]  Hiroshi Ishikawa,et al.  Optical coherence tomography (OCT) macular and peripapillary retinal nerve fiber layer measurements and automated visual fields. , 2004, American journal of ophthalmology.

[18]  Hiroshi Ishikawa,et al.  Effect of corneal drying on optical coherence tomography. , 2006, Ophthalmology.

[19]  Mingguang He,et al.  Prevalence and clinical characteristics of glaucoma in adult Chinese: a population-based study in Liwan District, Guangzhou. , 2006, Investigative ophthalmology & visual science.

[20]  D. Garway-Heath,et al.  Factors affecting the test-retest variability of Heidelberg retina tomograph and Heidelberg retina tomograph II measurements , 2005, British Journal of Ophthalmology.

[21]  R N Weinreb,et al.  Effect of cataract and pupil size on image quality with confocal scanning laser ophthalmoscopy. , 1997, Archives of ophthalmology.

[22]  F. Medeiros,et al.  Comparison of the GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and stratus OCT optical coherence tomograph for the detection of glaucoma. , 2004, Archives of ophthalmology.