Results from a Full-Scale Study on the Condition Assessment of Pendulum Tuned Mass Dampers

AbstractPendulum tuned mass dampers (PTMDs) are one of the most popular vibration control devices in use today for flexible towers, bridges, and buildings. Their most attractive feature is the design simplicity; the natural period can be controlled simply by adjusting the suspended length and viscous dampers can be easily integrated into the design. While this simplicity has resulted in their widespread adoption, the installed performance of PTMDs has not been investigated in much detail. This paper presents a methodology for conducting condition assessment of in-service PTMDs. Results from a full-scale study of a PTMD-equipped structure is used as a test bed to demonstrate the approach. The condition of an in-service PTMD is assessed using two criteria: the frequency and damping tuning ratios, and equivalent damping provided by the PTMD. These criteria are estimated while the PTMD is in service, without arresting the PTMD motion, using an extended Kalman filter. Practical considerations typical in full-s...

[1]  Li Zhou,et al.  An adaptive extended Kalman filter for structural damage identification , 2006 .

[2]  Andrew W. Smyth,et al.  On-Line Parametric Identification of MDOF Nonlinear Hysteretic Systems , 1999 .

[3]  Ahsan Kareem,et al.  Estimation of modal loads using structural response , 2009 .

[4]  Mal P. Sacks,et al.  Tuned Mass Dampers for Towers and Buildings , 1993 .

[5]  B. J. Vickery,et al.  Optimum design of pendulum‐type tuned mass dampers , 2005 .

[6]  Ahsan Kareem,et al.  Damping in structures: its evaluation and treatment of uncertainty , 1996 .

[7]  Sriram Narasimhan,et al.  Extended Kalman filter for modal identification of structures equipped with a pendulum tuned mass damper , 2014 .

[8]  W. D. Mark,et al.  Random Vibration in Mechanical Systems , 1963 .

[9]  Sriram Narasimhan,et al.  Performance of Pendulum Tuned Mass Dampers in Reducing the Responses of Flexible Structures , 2013 .

[10]  Stuart S. Chen,et al.  FUNDAMENTAL CONSIDERATIONS FOR THE DESIGN OF NON-LINEAR VISCOUS DAMPERS , 1999 .

[11]  P. Bélanger Estimation of noise covariance matrices for a linear time-varying stochastic process , 1972, Autom..

[12]  Li Zhou,et al.  Identification of parametric changes for civil engineering structures using an adaptive Kalman filter , 2004, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[13]  Sriram Narasimhan,et al.  Condition Assessment of an In-Service Pendulum Tuned Mass Damper , 2012 .

[14]  Garry A. Einicke,et al.  Robust extended Kalman filtering , 1999, IEEE Trans. Signal Process..

[15]  Kenny C. S Kwok,et al.  Perception of vibration and occupant comfort in wind-excited tall buildings , 2009 .

[16]  B. Anderson,et al.  Optimal Filtering , 1979, IEEE Transactions on Systems, Man, and Cybernetics.

[17]  Hiroshi Tanaka,et al.  Effect of tuned mass dampers on wind induced response of tall buildings , 1983 .

[18]  Budhaditya Hazra,et al.  Underdetermined Blind Identification of Structures by Using the Modified Cross-Correlation Method , 2012 .

[19]  Kenny C. S Kwok,et al.  Full-scale measurements of wind-induced acceleration response of Sydney Tower , 1990 .

[20]  Bijan Samali,et al.  Performance of tuned mass dampers under wind loads , 1995 .

[21]  M. Hoshiya,et al.  Structural Identification by Extended Kalman Filter , 1984 .

[22]  Sriram Narasimhan,et al.  Adaptive Compensation for Detuning in Pendulum Tuned Mass Dampers , 2011 .

[23]  T. T. Soong,et al.  Parametric study and simplified design of tuned mass dampers , 1998 .