Abstract This paper reports a study on how hourly temperature variations of different heat sources influence the seasonal coefficient of performance (SCOP) of heat pumps (HPs) when supplying district heating. The considered heat sources were: groundwater, seawater, air and a combination of the three. The system included HPs, an electric peak load boiler and short-term storage. Linear programming was used to minimize annual electricity consumption of the system. This process also determined the optimum capacities of the HPs using different heat sources. The study was based on data for the area of Copenhagen, Denmark. The results showed that the SCOP of seawater and air HPs, considering heat demand variations, was 11% and 15% lower, respectively, than their arithmetic mean performances. For a combination of heat sources, the optimum proportions of HP capacities were: 63%, 14% and 23% for the groundwater, seawater and air HP, respectively. The SCOP of such system was found to be 3%, 6% and 11% greater than the SCOP of a system using the heat sources individually. The results indicate that a maximum system performance may be achieved for HPs based on a combination of different heat sources.

[1]  Brian Vad Mathiesen,et al.  4th Generation District Heating (4GDH) Integrating smart thermal grids into future sustainable energy systems , 2014 .

[2]  Brian Elmegaard,et al.  Design of serially connected district heating heat pumps utilising a geothermal heat source , 2017 .

[3]  Olexandr Balyk,et al.  Energy system investment model incorporating heat pumps with thermal storage in buildings and buffer tanks , 2013 .

[4]  Yacine Rezgui,et al.  District heating and cooling optimization and enhancement – towards integration of renewables, storage and smart grid , 2017 .

[5]  Brian Vad Mathiesen,et al.  Smart Energy Systems: Holistic and Integrated Energy Systems for the era of 100% Renewable Energy , 2013 .

[6]  Juha Kiviluoma,et al.  Flexibility from district heating to decrease wind power integration costs , 2010 .

[7]  Brian Vad Mathiesen,et al.  Comparative analyses of seven technologies to facilitate the integration of fluctuating renewable energy sources , 2009 .

[8]  Sanna Syri,et al.  Heat pumps versus combined heat and power production as CO2 reduction measures in Finland , 2013 .

[9]  Torben Schmidt Ommen,et al.  Heat Pumps in CHP Systems: High-efficiency Energy System Utilising Combined Heat and Power and Heat Pumps , 2015 .

[10]  Lieve Helsen,et al.  Influence of massive heat‐pump introduction on the electricity‐generation mix and the GHG effect—Belgian case study , 2008 .

[11]  Kristina Holmgren,et al.  Role of a district-heating network as a user of waste-heat supply from various sources : the case of Göteborg , 2006 .

[12]  Dag Henning MODEST : an energy-system optimisation model applicable to local utilities and countries , 1997 .

[13]  Z. Ayub World's Largest Ammonia Heat Pump (14 MWh) for District Heating in Norway—A Case Study , 2016 .

[14]  Brian Vad Mathiesen,et al.  Heat Roadmap Europe: Large-Scale Electric Heat Pumps in District Heating Systems , 2017 .

[15]  M. B. Blarke,et al.  Large-scale heat pumps in sustainable energy systems: system and project perspectives , 2007 .

[16]  IDA Indoor Climate and Energy , 1999 .

[17]  Rasmus Søgaard Lund,et al.  Comparison of Low-temperature District Heating Concepts in a Long-Term Energy System Perspective , 2017 .

[18]  K Hoffmann,et al.  Ammonia heat pumps for district heating in Norway: a case study. , 2011 .

[19]  W. Brown Physical Properties of Seawater , 2016 .

[20]  Kim Bjarne Wittchen,et al.  - Reference Climate Dataset for Technical Dimensioning in Building, Construction and other Sectors , 2013 .

[21]  Anders N. Andersen,et al.  Booster heat pumps and central heat pumps in district heating , 2016 .

[22]  Sven Werner District Heating and Cooling , 2013 .

[23]  Bernard Marie Lachal,et al.  The role of district heating in achieving sustainable cities: comparative analysis of different heat scenarios for Geneva , 2017 .

[24]  Henrik Lund,et al.  Renewable Energy Systems: A Smart Energy Systems Approach to the Choice and Modeling of 100% Renewable Solutions , 2014 .

[25]  Natasa Nord,et al.  Necessary Measures to Include more Distributed Renewable Energy Sources into District Heating System , 2017 .

[26]  Brian Elmegaard,et al.  Integration of large-scale heat pumps in the district heating systems of Greater Copenhagen , 2016 .

[27]  Rasmus Søgaard Lund,et al.  Mapping of potential heat sources for heat pumps for district heating in Denmark , 2016 .

[28]  B. Mathiesen,et al.  A technical and economic analysis of one potential pathway to a 100% renewable energy system , 2014 .

[29]  Brian Elmegaard,et al.  Design of serially connected ammonia-water hybrid absorption-compression heat pumps for district heating with the utilisation of a geothermal heat source , 2016 .

[30]  B. Elmegaard,et al.  Integration of space heating and hot water supply in low temperature district heating , 2016 .

[31]  Brian Elmegaard,et al.  Exergetic evaluation of heat pump booster configurations in a low temperature district heating network , 2012 .

[32]  Rasmus Søgaard Lund,et al.  Socioeconomic potential for introducing large-scale heat pumps in district heating in Denmark , 2016 .

[33]  Thore Berntsson,et al.  Heat sources — technology, economy and environment , 2002 .

[34]  A. Heller,et al.  Modeling energy flexibility of low energy buildings utilizing thermal mass , 2016 .