Mobile Sensor Application for Kinematic Detection of the Knees

Objective To correctly measure the knee joint angle, this study utilized a Qualisys motion capture system and also used it as the reference to assess the validity of the study's Inertial Measurement Unit (IMU) system that consisted of four IMU sensors and the Knee Angle Recorder software. The validity was evaluated by the root mean square (RMS) of different angles and the intraclass correlation coefficient (ICC) values between the Qualisys system and the IMU system. Methods Four functional knee movement tests for ten healthy participants were investigated, which were the knee flexion test, the hip and knee flexion test, the forward step test and the leg abduction test, and the walking test. Results The outcomes of the knee flexion test, the hip and knee flexion test, the forward step test, and the walking test showed that the RMS of different angles were less than 6°. The ICC values were in the range of 0.84 to 0.99. However, the leg abduction test showed a poor correlation in the measurement of the knee abduction-adduction movement. Conclusion The IMU system used in this study is a new good method to measure the knee flexion-extension movement.

[1]  K. Aminian,et al.  Ambulatory measurement of 3D knee joint angle. , 2008, Journal of biomechanics.

[2]  B M Jolles,et al.  Functional calibration procedure for 3D knee joint angle description using inertial sensors. , 2009, Journal of biomechanics.

[3]  H. Boom,et al.  Real-time gait assessment utilizing a new way of accelerometry. , 1990, Journal of biomechanics.

[4]  Peter H Veltink,et al.  Accelerometer and rate gyroscope measurement of kinematics: an inexpensive alternative to optical motion analysis systems. , 2002, Journal of biomechanics.

[5]  M H Granat,et al.  A practical gait analysis system using gyroscopes. , 1999, Medical engineering & physics.

[6]  Kamiar Aminian,et al.  Capturing human motion using body‐fixed sensors: outdoor measurement and clinical applications , 2004, Comput. Animat. Virtual Worlds.

[7]  Peter H. Veltink,et al.  Measuring orientation of human body segments using miniature gyroscopes and accelerometers , 2005, Medical and Biological Engineering and Computing.

[8]  Ryo Takeda,et al.  Gait analysis using gravitational acceleration measured by wearable sensors. , 2009, Journal of biomechanics.

[9]  J R Morris,et al.  Accelerometry--a technique for the measurement of human body movements. , 1973, Journal of biomechanics.

[10]  K. Aminian,et al.  A new ambulatory system for comparative evaluation of the three-dimensional knee kinematics, applied to anterior cruciate ligament injuries , 2006, Knee Surgery, Sports Traumatology, Arthroscopy.

[11]  Diana Hodgins,et al.  Inertial sensor-based knee flexion/extension angle estimation. , 2009, Journal of biomechanics.

[12]  Julien Favre,et al.  Automatic measurement of key ski jumping phases and temporal events with a wearable system , 2012, Journal of sports sciences.

[13]  K Aminian,et al.  Ambulatory measurement of ankle kinetics for clinical applications. , 2011, Journal of biomechanics.

[14]  Tossaphon Jaysrichai,et al.  Application of inertial measurement units for angular motion detection , 2013 .

[15]  Kamiar Aminian,et al.  A new approach to accurate measurement of uniaxial joint angles based on a combination of accelerometers and gyroscopes , 2005, IEEE Transactions on Biomedical Engineering.

[16]  P.H. Veltink,et al.  Inclination measurement of human movement using a 3-D accelerometer with autocalibration , 2004, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[17]  Julien Favre,et al.  A system to measure the kinematics during the entire ski jump sequence using inertial sensors. , 2013, Journal of biomechanics.

[18]  Masahiro Todoh,et al.  Gait posture estimation using wearable acceleration and gyro sensors. , 2009, Journal of biomechanics.