Analysis of GDx-VCC polarimetry data by Wavelet-Fourier analysis across glaucoma stages.

PURPOSE The purpose of this study was to apply shape-based analysis techniques of retinal nerve fiber layer (RNFL) thickness to GDx-VCC (variable corneal and lens compensator; Laser Diagnostic Technologies, Inc., San Diego, CA) polarimetry data and to evaluate the techniques' ability to detect glaucoma in its earliest stages. Wavelet-based (wavelet-Fourier analysis [WFA]), Fourier-based (fast Fourier analysis [FFA]), and several previous variations of shape-based analysis were considered, as well as the standard metric nerve fiber indicator (NFI), and all were compared as a function of disease stage. METHODS GDx-VCC scans of one eye of each of 67 patients with glaucoma and each of 67 healthy age-matched subjects provided RNFL thickness estimates at a fixed distance from the optic disc. Severity of disease was graded according to the Glaucoma Staging System and also by mean deviation (MD) from standard automated perimetry. WFA, FFA, and NFI procedures were performed including the following variations: use of signed or unsigned phase, inclusion of interocular or intraocular asymmetry of analysis parameters, and combination of features by principle components analysis or Wilks lambda. Independent samples (k-fold variation) were used for training and testing. Sensitivity, specificity, and receiver operating characteristic (ROC) area were obtained. RESULTS Classification performance of WFA (ROC = 0.978) was significantly better than FFA (ROC = 0.938) and NFI (ROC = 0.900). This difference was largest for the earliest stages of glaucoma. Shape-based analysis methods performed better than NFI overall. Adding between-eye asymmetry measures helped FFA but not WFA. CONCLUSIONS Shape-based analysis, and WFA in particular, makes an important improvement in detecting earliest glaucoma with polarimetry.

[1]  H. Lemij,et al.  Prevalence of split nerve fiber layer bundles in healthy eyes imaged with scanning laser polarimetry. , 2001, Ophthalmology.

[2]  F. Fitzke,et al.  Scaling the hill of vision: the physiological relationship between light sensitivity and ganglion cell numbers. , 2000, Investigative ophthalmology & visual science.

[3]  E. Essock,et al.  A Novel Feature Extraction Method – Wavelet-Fourier Analysis and Its Application to Glaucoma Classification , 2003 .

[4]  E. Essock,et al.  Diffuse and Localized Nerve Fiber Layer Loss Measured With a Scanning Laser Polarimeter: Sensitivity and Specificity of Detecting Glaucoma , 2000, Journal of glaucoma.

[5]  Robert Tibshirani,et al.  An Introduction to the Bootstrap , 1994 .

[6]  A. Sommer,et al.  Clinically detectable nerve fiber atrophy precedes the onset of glaucomatous field loss. , 1991, Archives of ophthalmology.

[7]  J. Jonas,et al.  Retinal nerve fiber layer thickness in human eyes , 1999, Graefe's Archive for Clinical and Experimental Ophthalmology.

[8]  Abhijit S. Pandya,et al.  Pattern Recognition with Neural Networks in C++ , 1995 .

[9]  A. Tuulonen,et al.  Nerve fiber layer defects with normal visual fields. Do normal optic disc and normal visual field indicate absence of glaucomatous abnormality? , 1993, Ophthalmology.

[10]  H A Quigley,et al.  Quantitative studies of retinal nerve fiber layer defects. , 1982, Archives of ophthalmology.

[11]  R Varma,et al.  Retinal nerve fiber layer thickness in normal human eyes. , 1996, Ophthalmology.

[12]  Rafael C. González,et al.  Local Determination of a Moving Contrast Edge , 1985, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[13]  R. Weinreb,et al.  Histopathologic validation of Fourier-ellipsometry measurements of retinal nerve fiber layer thickness. , 1990, Archives of ophthalmology.

[14]  D. Greenfield,et al.  Optic nerve and retinal nerve fiber layer analyzers in glaucoma , 2002, Current opinion in ophthalmology.

[15]  C. Tosoni,et al.  Staging of Functional Damage in Glaucoma Using Frequency Doubling Technology , 2003, Journal of glaucoma.

[16]  C. Curcio,et al.  Topography of ganglion cells in human retina , 1990, The Journal of comparative neurology.

[17]  Robert N Weinreb,et al.  Fourier analysis of optical coherence tomography and scanning laser polarimetry retinal nerve fiber layer measurements in the diagnosis of glaucoma. , 2003, Archives of ophthalmology.

[18]  E. DeLong,et al.  Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. , 1988, Biometrics.

[19]  Richard O. Duda,et al.  Pattern classification and scene analysis , 1974, A Wiley-Interscience publication.

[20]  A. Sommer,et al.  An evaluation of optic disc and nerve fiber layer examinations in monitoring progression of early glaucoma damage. , 1992, Ophthalmology.

[21]  Robert D. Fechtner,et al.  Fourier Analysis of Nerve Fiber Layer Measurements From Scanning Laser Polarimetry in Glaucoma: Emphasizing Shape Characteristics of the ‘Double‐Hump’ Pattern , 2000, Journal of glaucoma.

[22]  A. Sommer,et al.  The nerve fiber layer in the diagnosis of glaucoma. , 1977, Archives of ophthalmology.

[23]  H. Jampel,et al.  Quantitative detection of glaucomatous damage at the posterior pole by retinal thickness mapping. A pilot study. , 1998, Ophthalmology.

[24]  G. Holder,et al.  Relationship between electrophysiological, psychophysical, and anatomical measurements in glaucoma. , 2002, Investigative ophthalmology & visual science.

[25]  Julia V Ponomarenko,et al.  Assigning new GO annotations to protein data bank sequences by combining structure and sequence homology , 2005, Proteins.

[26]  Philip P. Chen,et al.  Predicting Subsequent Visual Field Loss in Glaucomatous Subjects With Disc Hemorrhage Using Retinal Nerve Fiber Layer Polarimetry , 2005, Journal of glaucoma.

[27]  Robert N Weinreb,et al.  Fourier analysis of scanning laser polarimetry measurements with variable corneal compensation in glaucoma. , 2003, Investigative ophthalmology & visual science.

[28]  G. Dunkelberger,et al.  Retinal ganglion cell atrophy correlated with automated perimetry in human eyes with glaucoma. , 1989, American journal of ophthalmology.

[29]  P. Brusini Clinical use of a New Method for Visual Field Damage Classification in Glaucoma , 1996, European journal of ophthalmology.

[30]  M. Sugimoto,et al.  Symmetry Analysis for Detecting Early Glaucomatous Changes in Ocular Hypertension Using Optical Coherence Tomography , 2004, Japanese Journal of Ophthalmology.

[31]  R. Susanna,et al.  Comparison of algorithms for detection of localised nerve fibre layer defects using scanning laser polarimetry , 2003, The British journal of ophthalmology.

[32]  R. Weinreb,et al.  Individualized compensation of anterior segment birefringence during scanning laser polarimetry. , 2002, Investigative ophthalmology & visual science.