The combined concentric-ring and sector-vortex phased array for MRI guided ultrasound surgery

MRI guided ultrasound surgery requires small surgical equipment volumes to facilitate the treatment of larger patients in the limited space of a conventional MRI magnet. In addition, large focal volumes are required to reduce the treatment time of large tumors. The concentric-ring array is capable of moving the focus in one dimension, and previous studies have shown that a circular array composed of radial sectors is capable of producing enlarged focal volumes. These two array designs may be combined to create an array that is capable of both enlarging the focus and moving the focus along the axis of the array. Simulations were performed to predict the performance and capabilities of various combined array designs by using numerical routines to, calculate the acoustic power field, temperature distribution, and accumulated thermal dose. The results shown predict that the combined array can create necrosed tissue volumes over 30 times larger than the concentric-ring array while maintaining focal range. The simulation results were verified with an experimental array consisting of 13 rings and 4 sectors. In addition, simulations were performed where multiple focal patterns were cycled in the time domain to create an optimized heating pattern characterized by uniform thermal dose over the volume of the lesion. Such heating patterns resulted in a 40/spl deg/C lower maximum temperature compared to single mode sonications while producing the same necrosed tissue volume, and yielded a rate of necrosis of 26.4 cm/sup 3//h.

[1]  H. O'neil Theory of Focusing Radiators , 1949 .

[2]  F. Stuart Foster,et al.  Transient Fields of Concave Annular Arrays , 1981 .

[3]  P. Hartemann,et al.  Annular Array Transducer for Deep Acoustic Hyperthermia , 1981 .

[4]  C. J. Martin,et al.  Design of thermistor probes for measurement of ultrasound intensity distributions , 1983 .

[5]  W. Dewey,et al.  Thermal dose determination in cancer therapy. , 1984, International journal of radiation oncology, biology, physics.

[6]  Charles A. Cain,et al.  Concentric-Ring and Sector-Vortex Phased-Array Applicators for Ultrasound Hyperthermia , 1986 .

[7]  C. Cain,et al.  The sector-vortex phased array: acoustic field synthesis for hyperthermia , 1989, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[8]  R B Roemer,et al.  Effects of physical parameters on high temperature ultrasound hyperthermia. , 1990, Ultrasound in medicine & biology.

[9]  K. Hynynen The threshold for thermally significant cavitation in dog's thigh muscle in vivo. , 1991, Ultrasound in medicine & biology.

[10]  K. Hynynen,et al.  MRI-guided noninvasive ultrasound surgery. , 1993, Medical physics.

[11]  K. Hynynen,et al.  Design and experimental evaluation of an intracavitary ultrasound phased array system for hyperthermia , 1994, IEEE Transactions on Biomedical Engineering.

[12]  K Hynynen,et al.  The effect of various physical parameters on the size and shape of necrosed tissue volume during ultrasound surgery. , 1994, The Journal of the Acoustical Society of America.

[13]  F A Jolesz,et al.  Focused US system for MR imaging-guided tumor ablation. , 1995, Radiology.

[14]  K. Hynynen,et al.  Feasibility of using ultrasound phased arrays for MRI monitored noninvasive surgery , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  F A Jolesz,et al.  A clinical, noninvasive, MR imaging-monitored ultrasound surgery method. , 1996, Radiographics : a review publication of the Radiological Society of North America, Inc.

[16]  K Hynynen,et al.  Ultrasound surgery using multiple sonications--treatment time considerations. , 1996, Ultrasound in medicine & biology.

[17]  K. Hynynen,et al.  A parametric study of the concentric-ring transducer design for MRI guided ultrasound surgery. , 1996, The Journal of the Acoustical Society of America.