Development of a multi-exposure speckle imaging for mice brain imaging

In the last decade, Laser Speckle Contrast Imaging (LSCI) has been proposed and validated for imaging cerebral blood flow at the rodent brain surface in vivo. The technique relies on the calculation of the spatial speckle contrast, which is related to the velocity of scatterers (red blood cells). The implementation of the technique requires a partial craniotomy so that the brain tissues of interest can be illuminated with a laser diode. However, the studies of changes in the microcirculation during disease progression or treatment require longitudinal studies (i.e. imaging is done repeatedly over weeks or even months). Practically, the less invasive way to obtain such data is to image through the thinned skull without a craniotomy. However the presence of static scatterers (skull) will affect the speckle calculation and produce a bias in the estimation of the microcirculation changes. An extension to LSCI, termed Multi-Exposure Speckle Imaging (MESI) was proposed and validated a few years ago that address these limitations. It relies on a model of the speckle contrast as a function of the exposure time and the proportion of static scatterers. Here, we used MESI with the aim of repeatedly imaging the olfactory bulb of mice models of obesity. First, we have developed a MESI set up which was characterized on microfluidic flow phantoms with different flow-rates and channel diameters to simulate blood flow in animal model characteristics. Second, we show that MESI can discriminate flows in the presence of static scatterers and it can measure flow changes consistently. Finally we provide an in vivo validation of the technique in mice with and without a craniotomy.

[1]  Donald D Duncan,et al.  Can laser speckle flowmetry be made a quantitative tool? , 2008, Journal of the Optical Society of America. A, Optics, image science, and vision.

[2]  Phillip B. Jones,et al.  Simultaneous multispectral reflectance imaging and laser speckle flowmetry of cerebral blood flow and oxygen metabolism in focal cerebral ischemia. , 2008, Journal of biomedical optics.

[3]  Henry Pinkard,et al.  Advanced methods of microscope control using μManager software. , 2014, Journal of biological methods.

[4]  D. Boas,et al.  Laser speckle contrast imaging in biomedical optics. , 2010, Journal of biomedical optics.

[5]  A. Grinvald,et al.  A tandem-lens epifluorescence macroscope: Hundred-fold brightness advantage for wide-field imaging , 1991, Journal of Neuroscience Methods.

[6]  W. J. Tom,et al.  Robust flow measurement with multi-exposure speckle imaging. , 2008, Optics express.

[7]  M. Moskowitz,et al.  Laser Speckle Flowmetry for the Study of Cerebrovascular Physiology in Normal and Ischemic Mouse Cortex , 2004, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[8]  T. Jones,et al.  Chronic Imaging of Cortical Blood Flow using Multi-Exposure Speckle Imaging , 2013, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[9]  Andrew K. Dunn,et al.  Quantitative imaging of ischemic stroke through thinned skull in mice with Multi Exposure Speckle Imaging , 2010, Biomedical optics express.

[10]  Wiendelt Steenbergen,et al.  Laser speckle contrast imaging: theoretical and practical limitations , 2013, Journal of biomedical optics.

[11]  Anna Devor,et al.  Determination of optimal exposure time for imaging of blood flow changes with laser speckle contrast imaging. , 2005, Applied optics.

[12]  Kartikeya Murari,et al.  Multiexposure laser speckle contrast imaging of the angiogenic microenvironment. , 2011, Journal of biomedical optics.

[13]  Kartikeya Murari,et al.  High spatiotemporal resolution imaging of the neurovascular response to electrical stimulation of rat peripheral trigeminal nerve as revealed by in vivo temporal laser speckle contrast , 2009, Journal of Neuroscience Methods.

[14]  J. Briers,et al.  Flow visualization by means of single-exposure speckle photography , 1981 .

[15]  Anne Humeau-Heurtier,et al.  Blood Perfusion Values of Laser Speckle Contrast Imaging and Laser Doppler Flowmetry: Is a Direct Comparison Possible? , 2013, IEEE Transactions on Biomedical Engineering.