Single-camera full-range high-resolution spectral domain optical coherence tomography.

We developed spectral domain optical coherence tomography using a dual-channel spectrometer for complex conjugate artifacts (CCA) suppression. We used a three-line charge coupled device to simultaneously detect two interferometric spectra with 2π/3 phase difference. The complex interferometric signal was reconstructed by trigonometric manipulation of two real interferometric spectra, and then full-range images were obtained by use of inverse Fourier transform. Artifacts at direct current (DC) and the ghost remnant of the CCA are common issues with the previously reported two-spectrometer method because the slight mismatching between two spectral detection channels had strong negative effects on CCA suppression and appeared to be the limiting factor on system performance. This novel dual-channel spectrometer uses the same spectrometer optics for the two spectral detection channels and, therefore, achieves better matching between two spectral detection channels and consequently better performance in CCA suppression as compared with the dual spectrometer solution. Full-range imaging with CCA suppression up to ∼25  dB was demonstrated when imaging an attenuated reflector. The efficacy of both CCA and DC suppressions also was validated by imaging the anterior segment of a rat eye ex vivo. The quality of CCA-suppressed images was significantly improved with regard to those obtained with the dual-spectrometer design.

[1]  Y. Yasuno,et al.  Full-range, high-speed, high-resolution 1 microm spectral-domain optical coherence tomography using BM-scan for volumetric imaging of the human posterior eye. , 2008, Optics express.

[2]  Chiung-Ting Wu,et al.  Method for suppressing the mirror image in Fourier-domain optical coherence tomography. , 2011, Optics letters.

[3]  Changhuei Yang,et al.  Instantaneous complex conjugate resolved spectral domain and swept-source OCT using 3x3 fiber couplers. , 2005, Optics express.

[4]  Michael Pircher,et al.  Full range complex spectral domain optical coherence tomography without additional phase shifters. , 2007, Optics express.

[5]  J. Izatt,et al.  Complete complex conjugate resolved heterodyne swept-source optical coherence tomography using a dispersive optical delay line , 2011, Biomedical optics express.

[6]  A. Rollins,et al.  Intracoronary optical coherence tomography: a comprehensive review clinical and research applications. , 2009, JACC. Cardiovascular interventions.

[7]  Duan Fajie,et al.  Sinusoidal phase modulating interferometry system for 3D profile measurement , 2014 .

[8]  A. Fercher,et al.  Full range complex spectral optical coherence tomography technique in eye imaging. , 2002, Optics letters.

[9]  Ruikang K. Wang In vivo full range complex Fourier domain optical coherence tomography , 2007 .

[10]  J. Duker,et al.  Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation. , 2004, Optics express.

[11]  S. Yun,et al.  High-speed spectral-domain optical coherence tomography at 1.3 mum wavelength. , 2003, Optics express.

[12]  W. Drexler,et al.  Dispersion encoded full range frequency domain optical coherence tomography. , 2009, Optics express.

[13]  Joseph A Izatt,et al.  High-speed complex conjugate resolved retinal spectral domain optical coherence tomography using sinusoidal phase modulation. , 2007, Optics letters.

[14]  Changhuei Yang,et al.  Instantaneous quadrature low coherence interferometry with 3 x 3 fiber optic couplers , 2003, Conference on Lasers and Electro-Optics, 2003. CLEO '03..

[15]  Linbo Liu,et al.  Spectral-domain optical coherence tomography with dual-balanced detection for auto-correlation artifacts reduction. , 2015, Optics express.

[16]  Theo Lasser,et al.  Heterodyne Fourier domain optical coherence tomography for full range probing with high axial resolution. , 2006, Optics express.

[17]  J. Schuman,et al.  Optical coherence tomography. , 2000, Science.

[18]  B E Bouma,et al.  Elimination of depth degeneracy in optical frequency-domain imaging through polarization-based optical demodulation. , 2006, Optics letters.

[19]  R. Leitgeb,et al.  High speed full range complex spectral domain optical coherence tomography. , 2005, Optics express.

[20]  Martin F. Kraus,et al.  En face enhanced-depth swept-source optical coherence tomography features of chronic central serous chorioretinopathy. , 2014, Ophthalmology.

[21]  Linbo Liu,et al.  Spectral-domain optical coherence tomography with dual-balanced detection for autocorrelation artifacts reduction , 2018 .

[22]  J. Izatt,et al.  Quadrature Projection Complex Conjugate Resolved Fourier Domain Optical Coherence Tomography For Real Time Full Depth Imaging , 2006 .

[23]  Teresa C. Chen,et al.  In vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography. , 2004, Optics letters.

[24]  Kevin Hsu,et al.  Dual detection full range frequency domain optical coherence tomography. , 2010, Optics letters.

[25]  Ruikang K. Wang,et al.  Fourier domain optical coherence tomography achieves full range complex imaging in vivo by introducing a carrier frequency during scanning , 2007, Physics in medicine and biology.