Measurement of the refractive index of air and comparison with modified Edl?n's formulae

An air refractometer has been developed for accurate measurements of the refractive index of gases under well-defined conditions. Measurements have been performed for dry and moist air at four wavelengths distributed over the visible part of the spectrum. The measured values have been compared with values determined by modified Edlen's formulae and measured parameters. A fitting procedure is described to adjust the humidity dependence and the constant term of the dispersion formula so that optimum agreement is obtained. A standard deviation of 3 × 10-9 for the residuals describes the reproducibility of the measurements and the success of fitting. For 50 % relative humidity, a standard uncertainty of 10-8 for the fitted formulae is claimed, arising mainly from the uncertainty contributions of the air parameters.

[1]  B. Edĺen The Refractive Index of Air , 1966 .

[2]  P Giacomo,et al.  Equation for the Determination of the Density of Moist Air (1981) , 1982 .

[3]  R. Davis,et al.  Equation for the Determination of the Density of Moist Air (1981/91) , 1992 .

[4]  P. Ciddor Refractive index of air: new equations for the visible and near infrared. , 1996, Applied optics.

[5]  K. P. Birch,et al.  Precise determination of refractometric parameters for atmospheric gases , 1991 .

[6]  K. P. Birch,et al.  LETTER TO THE EDITOR: Correction to the Updated Edln Equation for the Refractive Index of Air , 1994 .

[7]  K. P. Birch,et al.  The results of a comparison between calculated and measured values of the refractive index of air , 1988 .

[8]  K. P. Birch,et al.  The measurement of humidity variations in gases resulting from the adsorption of water on to surfaces , 1988 .

[9]  R. Muijlwijk,et al.  Update of the Edlén Formulae for the Refractive Index of Air , 1988 .

[10]  K. P. Birch,et al.  An Updated Edln Equation for the Refractive Index of Air , 1993 .

[11]  W. Olsowski Automatisches Kalibriersystem für Betriebsanalysengeräte / Automatic calibration system for analysers , 1986 .

[12]  C L WILSON,et al.  Refractive index. , 1946, The Analyst.

[13]  K. E. Erickson Investigation of the Invariance of Atmospheric Dispersion with a Long-Path Refractometer* , 1962 .

[14]  E. F. Lowry The Infrared Absorption Spectrum of Carbon Monoxide , 1924 .

[15]  K. P. Birch,et al.  Optical path length changes induced in cell windows and solid etalons by evacuation , 1988 .

[16]  M. Downs,et al.  Improving the accuracy of the temperature measurement of gases by correction for the response delays in the thermal sensors , 1990 .

[17]  J. Beers,et al.  SHORT COMMUNICATION: Verification of Revised Water Vapour Correction to the Index of Refraction of Air , 1992 .

[18]  P. Carré Installation et utilisation du comparateur photoélectrique et interférentiel du Bureau International des Poids et Mesures , 1966 .