Development and validation of a liquid chromatography-mass spectrometry method for the determination of 4,5-diazafluoren-9-one.

A new liquid chromatography-mass spectrometry (LC-MS) method is developed and validated for the identification and determination of novel 4,5-diazafluoren-9-one compound. The method employs a Waters XTerra RP-18 column (150 mmx4.6 mm, i.d. 5 microm) with a mobile phase comprised of a (50:50, v/v) mixture of deionized water containing 0.2% acetic acid (solvent A) and methanol (solvent B) at a flow rate of 1 mL/min, at 35 degrees C. The detection is performed with photodiode-array (PDA) set at 210-400 nm and single quadropole mass spectrometer with electrospray ionization (ESI) positive ion mode. The chromatographic separation is achieved in less than 3 min. The linearity is established over the concentration range of 0.1-0.5 mg/mL (r2=1.000). The mean RSD values for intra- and inter-day precision studies are <2%. The recovery of 4,5-diazafluoren-9-one ranged between 99.84 and 99.97%. The limits of detection and quantitation are determined to be 0.58 and 0.1 mg/mL, respectively.

[1]  G. Shabir,et al.  Evaluation and Application of Best Practice in Analytical Method Validation , 2007 .

[2]  Xiangrong Zhang,et al.  Determination of 25-OH-PPD in rat plasma by high-performance liquid chromatography-mass spectrometry and its application in rat pharmacokinetic studies. , 2005, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[3]  T. Begley,et al.  Characterization of gamma-irradiated polyethylene terephthalate by liquid-chromatography–mass-spectrometry (LC–MS) with atmospheric-pressure chemical ionization (APCI) , 2006 .

[4]  K. Deventer,et al.  Quantitative analysis of androst-4-ene-3,6,17-trione and metabolites in human urine after the administration of a food supplement by liquid chromatography/ion trap-mass spectrometry. , 2005, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[5]  Z. Cai,et al.  Liquid chromatography/mass spectrometric analysis of rat samples for in vivo metabolism and pharmacokinetic studies of ginsenoside Rh2. , 2005, Rapid communications in mass spectrometry : RCM.

[6]  Yuanyuan Song,et al.  Simultaneous determination of carbamate and organophosphorus pesticides in fruits and vegetables by liquid chromatography-mass spectrometry. , 2005, Journal of chromatography. A.

[7]  B. Casetta,et al.  Determination of protein phosphorylation sites by mass spectrometry: a novel electrospray-based method. , 2005, Rapid communications in mass spectrometry : RCM.

[8]  Kuldeep Sharma,et al.  Validation of LC-MS electrospray ionisation method for quantitation of haloperidol in human plasma and its application to bioequivalence study , 2005 .

[9]  C. McEwen,et al.  Analysis of solids, liquids, and biological tissues using solids probe introduction at atmospheric pressure on commercial LC/MS instruments. , 2005, Analytical chemistry.

[10]  Megha S. Deshpande,et al.  Mixed-ligand complexes of ruthenium(II) incorporating a diazo ligand: Synthesis, characterization and DNA binding , 2005 .

[11]  Guangji Wang,et al.  Determination of schizandrin in rat plasma by high-performance liquid chromatography-mass spectrometry and its application in rat pharmacokinetic studies. , 2005, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[12]  D. Sohn,et al.  Liquid Chromatography–Mass Spectrometric Analysis of Compound K, a Ginseng Saponin Metabolite, in Rat Plasma , 2004 .

[13]  S. Naka,et al.  Synthesis and properties of 9,9'-diaryl-4,5-diazafluorenes. A new type of electron-transporting and hole-blocking material in EL device , 2004 .

[14]  W. Schoeller,et al.  Cyclopentadienone-like Behavior of Fluorenone and 4,5-Diazafluoren-9-one , 2004 .

[15]  Ghulam A. Shabir,et al.  Step-by-step analytical methods validation and protocol in the quality system compliance industry , 2004 .

[16]  I. Harruna,et al.  Synthesis of ligand monomers derived from 4,5-diazafluoren-9-one☆ , 2003 .

[17]  E. Gelpí Contributions of liquid chromatography-mass spectrometry to "highlights" of biomedical research. , 2003, Journal of chromatography. A.

[18]  W. Niessen,et al.  Progress in liquid chromatography-mass spectrometry instrumentation and its impact on high-throughput screening. , 2003, Journal of chromatography. A.

[19]  G. Shabir,et al.  Validation of high-performance liquid chromatography methods for pharmaceutical analysis. Understanding the differences and similarities between validation requirements of the US Food and Drug Administration, the US Pharmacopeia and the International Conference on Harmonization. , 2003, Journal of chromatography. A.

[20]  M. V. Rajasekharan,et al.  A Channel-Forming Polyiodide Network in [Cu(dafone)3]I12. A Tris Chelate of Dafone and a New Planar Structure for the I122- Ion (Dafone = 4,5-Diazafluoren-9-one) , 1997 .

[21]  S. Xiao,et al.  Molecular assemblies of diazafluorenone Schiff-base amphiphiles. II. The vesicle and its molecular aggregation behavior , 1994 .

[22]  F. Fronczek,et al.  Selective perturbation of ligand field excited states in polypyridine ruthenium(II) complexes , 1984 .