Confidence images for MR spectroscopic imaging

Automated spectral analysis and estimation of signal amplitudes from magnetic resonance data generally constitutes a difficult nonlinear optimization problem. Obtaining a measure of the degree of confidence that one has in the estimated parameters is as important as the estimates themselves. This is particularly important if clinical diagnoses are to be based on estimated metabolite levels, as in applications of MR Spectroscopic Imaging for human studies. In this report, a standard method of obtaining confidence intervals for nonlinear estimation is applied to simulated data and short‐TE clinical proton spectroscopic imaging data sets of human brain. So‐called “confidence images” are generated to serve as visual indicators of how much trust should be placed in interpretation of spatial variations seen in images derived from fitted metabolite parameter estimates. This method is introduced in a Bayesian framework to enable comparison with similar techniques using Cramer‐Rao bounds and the residuals of fitted results. Magn Reson Med 44:537–545, 2000. © 2000 Wiley‐Liss, Inc.

[1]  Steven Kay,et al.  Fundamentals Of Statistical Signal Processing , 2001 .

[2]  N. Schuff,et al.  Removal of lipid artifacts in 1H spectroscopic imaging by data extrapolation , 1996, Magnetic resonance in medicine.

[3]  N. Draper,et al.  Applied Regression Analysis: Draper/Applied Regression Analysis , 1998 .

[4]  Richard F. Gunst,et al.  Applied Regression Analysis , 1999, Technometrics.

[5]  William H. Press,et al.  Numerical recipes , 1990 .

[6]  C Boesch,et al.  Versatile frequency domain fitting using time domain models and prior knowledge , 1998, Magnetic resonance in medicine.

[7]  D. van Ormondt,et al.  Error theory for time-domain signal analysis with linear prediction and singular value decomposition , 1986 .

[8]  Richard E. Blahut,et al.  Principles and practice of information theory , 1987 .

[9]  Dimitris N. Politis,et al.  Computer-intensive methods in statistical analysis , 1998, IEEE Signal Process. Mag..

[10]  V. Govindaraju,et al.  Automated spectral analysis III: Application to in Vivo proton MR Spectroscopy and spectroscopic imaging , 1998, Magnetic resonance in medicine.

[11]  D J Drost,et al.  Quantifying 1H decoupled in vivo 31P brain spectra , 1999, NMR in biomedicine.

[12]  S. Provencher Estimation of metabolite concentrations from localized in vivo proton NMR spectra , 1993, Magnetic resonance in medicine.

[13]  R Gruetter,et al.  Toward an in vivo neurochemical profile: quantification of 18 metabolites in short-echo-time (1)H NMR spectra of the rat brain. , 1999, Journal of magnetic resonance.

[14]  R de Beer,et al.  Application of time‐domain fitting in the quantification of in vivo 1H spectroscopic imaging data sets , 1992, NMR in biomedicine.