Single‐voxel MRS with prospective motion correction and retrospective frequency correction

Subject motion during MRS investigations is a factor limiting the quality and the diagnostic value of the spectra. The possibility of using external motion tracking data to correct for artefacts in MR imaging has been demonstrated previously. In this paper the utility of prospective motion correction for single‐voxel proton MRS is investigated. The object motion data are used in real time to update the position of the spectroscopy voxel during the acquisition prior to every sequence repetition cycle. It is not, however, sufficient to update the voxel position alone due to shim changes accompanying subject motion. Adverse effects of frequency shifts induced by subject motion are effectively suppressed by the interleaved reference scan method. Copyright © 2010 John Wiley & Sons, Ltd.

[1]  P. Börnert,et al.  Prospective correction of affine motion for arbitrary MR sequences on a clinical scanner , 2005, Magnetic resonance in medicine.

[2]  Fenghua Jin,et al.  Prospective head‐movement correction for high‐resolution MRI using an in‐bore optical tracking system , 2009, Magnetic resonance in medicine.

[3]  S. Provencher Estimation of metabolite concentrations from localized in vivo proton NMR spectra , 1993, Magnetic resonance in medicine.

[4]  G. Elbel,et al.  Phase coherent averaging in magnetic resonance spectroscopy using interleaved navigator scans: Compensation of motion artifacts and magnetic field instabilities , 2002, Magnetic resonance in medicine.

[5]  H. Ward,et al.  Spherical navigator echoes for full 3D rigid body motion measurement in MRI , 2002 .

[6]  Michael Schär,et al.  On restoring motion‐induced signal loss in single‐voxel magnetic resonance spectra , 2006, Magnetic resonance in medicine.

[7]  Oliver Speck,et al.  Magnetic resonance imaging of freely moving objects: prospective real-time motion correction using an external optical motion tracking system , 2006, NeuroImage.

[8]  Kay Nehrke,et al.  Prospective Intra-Image Compensation for Non-Periodic Rigid Body Motion Using Active Markers , 2006 .

[9]  T. G. Reese,et al.  High-order MR shimming: a simulation study of the effectiveness of competing methods, using an established susceptibility model of the human head , 2005 .

[10]  J. Felmlee,et al.  Orbital navigator echoes for motion measurements in magnetic resonance imaging , 1995, Magnetic resonance in medicine.

[11]  Michael Garwood,et al.  Measurement and correction of respiration‐induced B0 variations in breast 1H MRS at 4 Tesla , 2004, Magnetic resonance in medicine.

[12]  S. Provencher Automatic quantitation of localized in vivo 1H spectra with LCModel , 2001, NMR in biomedicine.

[13]  O. Speck,et al.  Prospective Real-Time Slice-by-Slice Motion Correction for fMRI in Freely Moving Subjects , 2006, Magnetic Resonance Materials in Physics, Biology and Medicine.

[14]  R. Kreis Issues of spectral quality in clinical 1H‐magnetic resonance spectroscopy and a gallery of artifacts , 2004, NMR in biomedicine.

[15]  S. Holtås,et al.  Proton MR spectroscopy in clinical routine , 2001, Journal of magnetic resonance imaging : JMRI.