Guidance document on delivery, treatment planning, and clinical implementation of IMRT: report of the IMRT Subcommittee of the AAPM Radiation Therapy Committee.

Intensity-modulated radiation therapy (IMRT) represents one of the most significant technical advances in radiation therapy since the advent of the medical linear accelerator. It allows the clinical implementation of highly conformal nonconvex dose distributions. This complex but promising treatment modality is rapidly proliferating in both academic and community practice settings. However, these advances do not come without a risk. IMRT is not just an add-on to the current radiation therapy process; it represents a new paradigm that requires the knowledge of multimodality imaging, setup uncertainties and internal organ motion, tumor control probabilities, normal tissue complication probabilities, three-dimensional (3-D) dose calculation and optimization, and dynamic beam delivery of nonuniform beam intensities. Therefore, the purpose of this report is to guide and assist the clinical medical physicist in developing and implementing a viable and safe IMRT program. The scope of the IMRT program is quite broad, encompassing multileaf-collimator-based IMRT delivery systems, goal-based inverse treatment planning, and clinical implementation of IMRT with patient-specific quality assurance. This report, while not prescribing specific procedures, provides the framework and guidance to allow clinical radiation oncology physicists to make judicious decisions in implementing a safe and efficient IMRT program in their clinics.

[1]  J. Palta,et al.  Comprehensive QA for radiation oncology: report of AAPM Radiation Therapy Committee Task Group 40. , 1994, Medical physics.

[2]  Cedric X. Yu,et al.  Intensity-modulated arc therapy with dynamic multileaf collimation: an alternative to tomotherapy. , 1995, Physics in medicine and biology.

[3]  T LoSasso,et al.  Testing of dynamic multileaf collimation. , 1996, Medical physics.

[4]  J. V. van Santvoort,et al.  Dynamic multileaf collimation without 'tongue-and-groove' underdosage effects. , 1996, Physics in medicine and biology.

[5]  T LoSasso,et al.  Dosimetric verification of intensity-modulated fields. , 1996, Medical physics.

[6]  T. Bortfeld,et al.  Number and orientations of beams in intensity-modulated radiation treatments. , 1997, Medical physics.

[7]  A L Boyer,et al.  Geometric analysis of light-field position of a multileaf collimator with curved ends. , 1997, Medical physics.

[8]  J. Deasy Multiple local minima in radiotherapy optimization problems with dose-volume constraints. , 1997, Medical physics.

[9]  A L Boyer,et al.  Modulated beam conformal therapy for head and neck tumors. , 1997, International journal of radiation oncology, biology, physics.

[10]  D Followill,et al.  Estimates of whole-body dose equivalent produced by beam intensity modulated conformal therapy. , 1997, International journal of radiation oncology, biology, physics.

[11]  D A Jaffray,et al.  The effects of intra-fraction organ motion on the delivery of dynamic intensity modulation. , 1998, Physics in medicine and biology.

[12]  D. Low,et al.  Phantoms for IMRT dose distribution measurement and treatment verification. , 1998, International journal of radiation oncology, biology, physics.

[13]  S. Webb Configuration options for intensity-modulated radiation therapy using multiple static fields shaped by a multileaf collimator. , 1998, Physics in medicine and biology.

[14]  C. Ling,et al.  Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy. , 1998, Medical physics.

[15]  D. Low,et al.  Quality assurance of serial tomotherapy for head and neck patient treatments. , 1998, International journal of radiation oncology, biology, physics.

[16]  J M Wilkinson,et al.  Rectangular edge synchronization for intensity modulated radiation therapy with dynamic multileaf collimation. , 1998, Physics in medicine and biology.

[17]  A L Boyer,et al.  An optimized leaf-setting algorithm for beam intensity modulation using dynamic multileaf collimators , 1998, Physics in medicine and biology.

[18]  S Mutic,et al.  A commercial IMRT treatment-planning dose-calculation algorithm. , 1998, International journal of radiation oncology, biology, physics.

[19]  J R Sykes,et al.  An experimental investigation of the tongue and groove effect for the Philips multileaf collimator. , 1998, Physics in medicine and biology.

[20]  P. Xia,et al.  Multileaf collimator leaf sequencing algorithm for intensity modulated beams with multiple static segments. , 1998, Medical physics.

[21]  G. Starkschall,et al.  American Association of Physicists in Medicine Radiation Therapy Committee Task Group 53: quality assurance for clinical radiotherapy treatment planning. , 1998, Medical physics.

[22]  S. Spirou,et al.  A gradient inverse planning algorithm with dose-volume constraints. , 1998, Medical physics.

[23]  K M Ayyangar,et al.  On compensator design for photon beam intensity-modulated conformal therapy. , 1998, Medical physics.

[24]  G J Budgell Temporal resolution requirements for intensity modulated radiation therapy delivered by multileaf collimators. , 1999, Physics in medicine and biology.

[25]  A L Boyer,et al.  Synchronizing dynamic multileaf collimators for producing two-dimensional intensity-modulated fields with minimum beam delivery time. , 1999, International journal of radiation oncology, biology, physics.

[26]  L Verhey,et al.  Static field intensity modulation to treat a dominant intra-prostatic lesion to 90 Gy compared to seven field 3-dimensional radiotherapy. , 1999, International journal of radiation oncology, biology, physics.

[27]  T R Mackie,et al.  Characterization of the output for helical delivery of intensity modulated slit beams. , 1999, Medical physics.

[28]  E B Podgorsak,et al.  Verification of segmented beam delivery using a commercial electronic portal imaging device. , 1999, Medical physics.

[29]  M. Phillips,et al.  A macropencil beam model: clinical implementation for conformal and intensity modulated radiation therapy. , 1999, Physics in medicine and biology.

[30]  S Mutic,et al.  Abutment region dosimetry for serial tomotherapy. , 1999, International journal of radiation oncology, biology, physics.

[31]  A L Boyer,et al.  Optimization of importance factors in inverse planning. , 1999, Physics in medicine and biology.

[32]  J. Dempsey,et al.  Evaluation of polymer gels and MRI as a 3-D dosimeter for intensity-modulated radiation therapy. , 1999, Medical physics.

[33]  A L Boyer,et al.  Intensity-modulated radiation therapy with dynamic multileaf collimators. , 1999, Seminars in radiation oncology.

[34]  J. Tsai,et al.  A non-invasive immobilization system and related quality assurance for dynamic intensity modulated radiation therapy of intracranial and head and neck disease. , 1999, International journal of radiation oncology, biology, physics.

[35]  K. Forster,et al.  Dosimetric verification of a commercial inverse treatment planning system. , 1999, Physics in medicine and biology.

[36]  J. G. Li,et al.  Estimation theory and model parameter selection for therapeutic treatment plan optimization. , 1999, Medical physics.

[37]  H. Sandler,et al.  Optimization and clinical use of multisegment intensity-modulated radiation therapy for high-dose conformal therapy. , 1999, Seminars in radiation oncology.

[38]  E. B. Butler,et al.  Smart (simultaneous modulated accelerated radiation therapy) boost: a new accelerated fractionation schedule for the treatment of head and neck cancer with intensity modulated radiotherapy. , 1999, International journal of radiation oncology, biology, physics.

[39]  A. Brahme,et al.  Optimized radiation therapy based on radiobiological objectives. , 1999, Seminars in radiation oncology.

[40]  W. Que Comparison of algorithms for multileaf collimator field segmentation. , 1999, Medical physics.

[41]  B. Fallone,et al.  Accuracy of numerically produced compensators. , 1999, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[42]  C. Langer,et al.  Concurrent chemoradiation using paclitaxel and carboplatin in locally advanced non-small cell lung cancer. , 1999, Seminars in radiation oncology.

[43]  G J Kutcher,et al.  Intensity-modulated tangential beam irradiation of the intact breast. , 1999, International journal of radiation oncology, biology, physics.

[44]  R. Siochi,et al.  Minimizing static intensity modulation delivery time using an intensity solid paradigm. , 1999, International journal of radiation oncology, biology, physics.

[45]  D A Jaffray,et al.  Managing geometric uncertainty in conformal intensity-modulated radiation therapy. , 1999, Seminars in radiation oncology.

[46]  C M Ma,et al.  Theoretical considerations of monitor unit calculations for intensity modulated beam treatment planning. , 1999, Medical physics.

[47]  S B Jiang,et al.  Monte Carlo verification of IMRT dose distributions from a commercial treatment planning optimization system. , 2000, Physics in medicine and biology.

[48]  A. Hanlon,et al.  Ultrasound-based stereotactic guidance of precision conformal external beam radiation therapy in clinically localized prostate cancer. , 2000, Urology.

[49]  W. Tomé,et al.  A spiral phantom for IMRT and tomotherapy treatment delivery verification. , 2000, Medical physics.

[50]  W. Grant,et al.  A clinical evaluation of setup errors for a prostate immobilization system , 2000, Journal of applied clinical medical physics.

[51]  K. Burnham,et al.  Some limitations in the practical delivery of intensity modulated radiation therapy. , 2000, The British journal of radiology.

[52]  C. De Wagter,et al.  The value of the PinPoint ion chamber for characterization of small field segments used in intensity-modulated radiotherapy. , 2000, Physics in medicine and biology.

[53]  L. Xing,et al.  Inverse planning incorporating organ motion , 2000, Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (Cat. No.00CH37143).

[54]  Y Chen,et al.  Monitor unit calculation for an intensity modulated photon field by a simple scatter-summation algorithm. , 2000, Physics in medicine and biology.

[55]  R Mohan,et al.  Radiobiological considerations in the design of fractionation strategies for intensity-modulated radiation therapy of head and neck cancers. , 2000, International journal of radiation oncology, biology, physics.

[56]  C C Ling,et al.  Clinical experience with intensity modulated radiation therapy (IMRT) in prostate cancer. , 2000, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[57]  J. Galvin,et al.  An optimized forward-planning technique for intensity modulated radiation therapy. , 2000, Medical physics.

[58]  G T Chen,et al.  A monitor unit verification calculation in intensity modulated radiotherapy as a dosimetry quality assurance. , 2000, Medical physics.

[59]  P S Cho,et al.  Hardware-sensitive optimization for intensity modulated radiotherapy. , 2000, Physics in medicine and biology.

[60]  P. C. Williams,et al.  Requirements for leaf position accuracy for dynamic multileaf collimation. , 2000, Physics in medicine and biology.

[61]  B. Emami,et al.  Improvement of tomographic intensity modulated radiotherapy dose distributions using periodic shifting of arc abutment regions. , 2000, Medical physics.

[62]  M J Rivard,et al.  Dependence of linac output on the switch rate of an intensity-modulated tomotherapy collimator. , 2000, Medical physics.

[63]  B J Heijmen,et al.  Testing of the stability of intensity modulated beams generated with dynamic multileaf collimation, applied to the MM50 racetrack microtron. , 2000, Medical physics.

[64]  D Yan,et al.  Monitor unit settings for intensity modulated beams delivered using a step-and-shoot approach. , 2000, Medical physics.

[65]  G T Chen,et al.  Intensity modulated radiotherapy dose delivery error from radiation field offset inaccuracy. , 2000, Medical physics.

[66]  A L Boyer,et al.  Dosimetric effects of patient displacement and collimator and gantry angle misalignment on intensity modulated radiation therapy. , 2000, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[67]  C.-W. Chen,et al.  Comparison of beam characteristics in intensity modulated radiation therapy (IMRT) and those under normal treatment condition , 2000, Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (Cat. No.00CH37143).

[68]  R Mohan,et al.  Algorithms and functionality of an intensity modulated radiotherapy optimization system. , 2000, Medical physics.

[69]  Verification of IMRT dose distributions using a water beam imaging system , 2000, Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (Cat. No.00CH37143).

[70]  M van Herk,et al.  Leaf position verification during dynamic beam delivery: a comparison of three applications using electronic portal imaging. , 2000, Medical physics.

[71]  C C Ling,et al.  Relative profile and dose verification of intensity-modulated radiation therapy. , 2000, International journal of radiation oncology, biology, physics.

[72]  Yan Chen,et al.  Calculation of x-ray transmission through a multileaf collimator. , 2000, Medical physics.

[73]  R Mohan,et al.  Dynamic splitting of large intensity-modulated fields. , 2000, Physics in medicine and biology.

[74]  M Partridge,et al.  The delivery of intensity modulated radiotherapy to the breast using multiple static fields. , 2000, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[75]  Robert C. Frazier,et al.  Intensity modulation to improve dose uniformity with tangential breast radiotherapy: initial clinical experience. , 2000, International journal of radiation oncology, biology, physics.

[76]  R Jeraj,et al.  The effect of statistical uncertainty on inverse treatment planning based on Monte Carlo dose calculation. , 2000, Physics in medicine and biology.

[77]  P Rüegsegger,et al.  Theoretical considerations to the verification of dynamic multileaf collimated fields with a SLIC-type portal image detector. , 2000, Physics in medicine and biology.

[78]  L Xing,et al.  Computer verification of fluence map for intensity modulated radiation therapy. , 2000, Medical physics.

[79]  R Mohan,et al.  The impact of fluctuations in intensity patterns on the number of monitor units and the quality and accuracy of intensity modulated radiotherapy. , 2000, Medical physics.

[80]  N Dogan,et al.  A modified method of planning and delivery for dynamic multileaf collimator intensity-modulated radiation therapy. , 2000, International journal of radiation oncology, biology, physics.

[81]  C S Chui,et al.  Inverse planning algorithms for external beam radiation therapy. , 2001, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[82]  James E. Rodgers,et al.  Radiation therapy vault shielding calculational methods when IMRT and TBI procedures contribute , 2001, Journal of applied clinical medical physics.

[83]  B. Heijmen,et al.  Commissioning of a commercially available system for intensity-modulated radiotherapy dose delivery with dynamic multileaf collimation. , 2001, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[84]  R. Mohan,et al.  Motion adaptive x-ray therapy: a feasibility study , 2001, Physics in medicine and biology.

[85]  K M Ayyangar,et al.  Commissioning of Peacock System for intensity-modulated radiation therapy. , 2001, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[86]  MLC-based IMRT-Part II. , 2001, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[87]  C. Ma,et al.  The MLC tongue-and-groove effect on IMRT dose distributions. , 2001, Physics in medicine and biology.

[88]  P S Cho,et al.  Leaf sequencing with secondary beam blocking under leaf positioning constraints for continuously modulated radiotherapy beams. , 2001, Medical physics.

[89]  P Hofman,et al.  An improved breast irradiation technique using three-dimensional geometrical information and intensity modulation. , 2001, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[90]  Abutment dosimetry for serial tomotherapy. , 2001, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[91]  R Mohan,et al.  The effect of setup uncertainty on normal tissue sparing with IMRT for head-and-neck cancer. , 2001, International journal of radiation oncology, biology, physics.

[92]  Intensity modulated irradiation of a thorax phantom: comparisons between measurements, Monte Carlo calculations and pencil beam calculations. , 2001, Physics in medicine and biology.

[93]  R Mohan,et al.  Monte Carlo dose calculations for dynamic IMRT treatments. , 2001, Physics in medicine and biology.

[94]  B J Salter,et al.  An oblique arc capable patient positioning system for sequential tomotherapy. , 2001, Medical physics.

[95]  B. Salter NOMOS Peacock IMRT utilizing the Beak post collimation device. , 2001, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[96]  F. Claus,et al.  An implementation strategy for IMRT of ethmoid sinus cancer with bilateral sparing of the optic pathways. , 2001, International journal of radiation oncology, biology, physics.

[97]  Gary A. Ezzell,et al.  The overshoot phenomenon in step‐and‐shoot IMRT delivery , 2001, Journal of applied clinical medical physics.

[98]  F Verhaegen,et al.  A method of simulating dynamic multileaf collimators using Monte Carlo techniques for intensity-modulated radiation therapy. , 2001, Physics in medicine and biology.

[99]  T. Holmes,et al.  Analysing collimator structure effects in head-scatter calculations for IMRT class fields using scatter raytracing. , 2001, Physics in medicine and biology.

[100]  MIMiC-based IMRT- part I. , 2001, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[101]  C. Ramsey,et al.  Leaf position error during conformal dynamic arc and intensity modulated arc treatments. , 2001, Medical physics.

[102]  W. De Gersem,et al.  An anatomy-based beam segmentation tool for intensity-modulated radiation therapy and its application to head-and-neck cancer. , 2001, International journal of radiation oncology, biology, physics.

[103]  D A Low,et al.  Interleaf leakage for 5 and 10 mm dynamic multileaf collimation systems incorporating patient motion. , 2001, Medical physics.

[104]  T LoSasso,et al.  Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode. , 2001, Medical physics.

[105]  R Mohan,et al.  Acceleration of dose calculations for intensity-modulated radiotherapy. , 2001, Medical physics.

[106]  C. Enke,et al.  Immobilization devices for intensity-modulated radiation therapy (IMRT). , 2001, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[107]  C. De Wagter,et al.  The value of the LA48 linear ion chamber array for characterization of intensity-modulated beams. , 2001, Physics in medicine and biology.

[108]  X A Li,et al.  Optimized intensity‐modulated arc therapy for prostate cancer treatment , 2001, International journal of cancer.

[109]  A W Beavis,et al.  Optimization of the step-and-shoot leaf sequence for delivery of intensity modulated radiation therapy using a variable division scheme. , 2001, Physics in medicine and biology.

[110]  James A. Purdy,et al.  Intensity-modulated radiotherapy: current status and issues of interest. , 2001, International journal of radiation oncology, biology, physics.

[111]  S Mutic,et al.  Characterization of a commercial multileaf collimator used for intensity modulated radiation therapy. , 2001, Medical physics.

[112]  Independent dose calculations for the PEACOCK System. , 2001, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[113]  Y Watanabe Point dose calculations using an analytical pencil beam kernel for IMRT plan checking. , 2001, Physics in medicine and biology.

[114]  F. Claus,et al.  Evaluation of a leaf position optimization tool for intensity modulated radiation therapy of head and neck cancer. , 2001, Radiotherapy and Oncology.

[115]  S Mutic,et al.  Room shielding for intensity-modulated radiation therapy treatment facilities. , 2001, International journal of radiation oncology, biology, physics.

[116]  C C Ling,et al.  Delivery of intensity-modulated radiation therapy with a conventional multileaf collimator: comparison of dynamic and segmental methods. , 2001, Medical physics.

[117]  T L Phillips,et al.  Toxicity following high-dose three-dimensional conformal and intensity-modulated radiation therapy for clinically localized prostate cancer. , 2001, Urology.

[118]  D L McShan,et al.  Calibration and quality assurance for rounded leaf-end MLC systems. , 2001, Medical physics.

[119]  B. Salter,et al.  The TALON removable head frame system for stereotactic radiosurgery/radiotherapy: measurement of the repositioning accuracy. , 2001, International journal of radiation oncology, biology, physics.

[120]  M. Langer,et al.  Improved leaf sequencing reduces segments or monitor units needed to deliver IMRT using multileaf collimators. , 2001, Medical physics.

[121]  Development of a treatment planning protocol for prostate treatments using intensity modulated radiotherapy , 2001, Journal of applied clinical medical physics.

[122]  Sampling considerations for intensity modulated radiotherapy verification using electronic portal imaging. , 2001, Medical physics.

[123]  J. Dai,et al.  Minimizing the number of segments in a delivery sequence for intensity-modulated radiation therapy with a multileaf collimator. , 2001, Medical physics.

[124]  D Yan,et al.  Implementing multiple static field delivery for intensity modulated beams. , 2001, Medical physics.

[125]  P Xia,et al.  Delivery systems of intensity-modulated radiotherapy using conventional multileaf collimators. , 2001, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[126]  W. De Gersem,et al.  Leaf position optimization for step-and-shoot IMRT. , 2001, International journal of radiation oncology, biology, physics.

[127]  Monte Carlo dose verification for intensity-modulated arc therapy. , 2001, Physics in medicine and biology.

[128]  K M Ayyangar,et al.  Quality assurance procedures for the Peacock system. , 2001, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[129]  J Yang,et al.  Smoothing intensity-modulated beam profiles to improve the efficiency of delivery. , 2001, Medical physics.

[130]  E. B. Butler,et al.  Prostate immobilization using a rectal balloon , 2002, Journal of applied clinical medical physics.

[131]  R. Mohan,et al.  Reducing dose calculation time for accurate iterative IMRT planning. , 2002, Medical physics.

[132]  R. Mohan,et al.  Optimization of intensity-modulated radiotherapy plans based on the equivalent uniform dose. , 2002, International journal of radiation oncology, biology, physics.

[133]  Timothy J Cullip,et al.  A quality and efficiency analysis of the IMFAST segmentation algorithm in head and neck "step & shoot" IMRT treatments. , 2002, Medical physics.

[134]  L Xing,et al.  Minimizing delivery time and monitor units in static IMRT by leaf-sequencing. , 2002, Physics in medicine and biology.

[135]  Quality assurance in IMRT: importance of the transmission through the jaws for an accurate calculation of absolute doses and relative distributions. , 2002, Medical physics.

[136]  Ping Xia,et al.  Communication and sampling rate limitations in IMRT delivery with a dynamic multileaf collimator system. , 2002, Medical physics.

[137]  A. Olch Dosimetric performance of an enhanced dose range radiographic film for intensity-modulated radiation therapy quality assurance. , 2002, Medical physics.

[138]  Joos V Lebesque,et al.  Reduction of rectal dose by integration of the boost in the large-field treatment plan for prostate irradiation. , 2002, International journal of radiation oncology, biology, physics.

[139]  Inhwan Jason Yeo,et al.  Film dosimetry for intensity modulated radiation therapy: dosimetric evaluation. , 2002, Medical physics.

[140]  Lei Xing,et al.  A three-source model for the calculation of head scatter factors. , 2002, Medical physics.

[141]  P Williams Clinical Implementation of IMRT , 2005 .