Effect of rotational alignment on patellar tracking in total knee arthroplasty.

Forty-four consecutive patients (65 knees) who underwent identical condylar type total knee arthroplasty were evaluated retrospectively. In 22 of the patients (32 knees), the femoral component was set parallel to the posterior condylar axis (neutrally aligned group). In the remaining 22 patients (33 knees), it was set in an external rotation position of 3 degrees to 5 degrees relative to the axis (externally aligned group). Of the total knee arthroplasties in the neutrally aligned group, 34% required lateral release, compared with only 6% in the externally aligned group; patellar tracking in the externally aligned group was significantly better than that in the neutrally aligned group. Postoperative measurements performed using computed tomography scans showed that the mean angle between the prosthetic posterior condylar axis and the transepicondylar axis was 7.9 degrees in the neutrally aligned group and 3.2 degrees in the externally aligned group. The external rotation setting of the femoral component diminished the need for lateral retinacular release and may decrease the rate of patellofemoral complications that occur after total knee arthroplasty.

[1]  B. Bierbaum,et al.  Bone scanning in the assessment of patellar viability following knee replacement. , 1985, Clinical orthopaedics and related research.

[2]  R A Berger,et al.  Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. , 1993, Clinical orthopaedics and related research.

[3]  M. Clayton,et al.  Patellar complications after total condylar arthroplasty. , 1982, Clinical orthopaedics and related research.

[4]  R. Laskin Flexion space configuration in total knee arthroplasty. , 1995, The Journal of arthroplasty.

[5]  J D Reuben,et al.  The effect of femoral component position on patellar tracking after total knee arthroplasty. , 1990, Clinical orthopaedics and related research.

[6]  R. Bloebaum,et al.  Implications of reference axes used for rotational alignment of the femoral component in primary and revision knee arthroplasty. , 1992, The Journal of arthroplasty.

[7]  L. S. M. Gomes,et al.  Patellar prosthesis positioning in total knee arthroplasty , 1988 .

[8]  J B Stiehl,et al.  Femoral Rotational Alignment Using the Tibial Shaft Axis in Total Knee Arthroplasty , 1996, Clinical orthopaedics and related research.

[9]  C. Ranawat,et al.  The patellofemoral joint in total condylar knee arthroplasty. Pros and cons based on five- to ten-year follow-up observations. , 1986, Clinical orthopaedics and related research.

[10]  J. N. Grace Patellar insatability after total knee arthroplasty , 1988 .

[11]  L. Whiteside,et al.  The Anteroposterior Axis for Femoral Rotational Alignment in Valgus Total Knee Arthroplasty , 1995, Clinical orthopaedics and related research.

[12]  T P Andriacchi,et al.  Patellar component failure in cementless total knee arthroplasty. , 1988, Clinical orthopaedics and related research.

[13]  Y. Iwamoto,et al.  Femoral Condyle Geometry in the Normal and Varus Knee , 1998, Clinical orthopaedics and related research.