Locating a catheter transducer in a three-dimensional ultrasound imaging field

Cardiac procedures rely on fluoroscopy for catheter guidance and visualization. However, fluoroscopy provides poor contrast of myocardial structures and exposes both the patient and health care providers to ionizing radiation. As an alternative to fluoroscopy, real-time three-dimensional (3-D) ultrasound imaging has the potential to provide a safe means for tracking catheter position in 3-D while simultaneously imaging the heart's anatomy. A method is described for locating a catheter-mounted transducer in the 3-D ultrasound imaging field. The distance from the imaging transducer to the catheter transducer is measured by time of flight, while the angular position is determined by a spatial crosscorrelation of the received signals with stored receive profiles. Results from simulations with 20-dB SNR demonstrated a mean accuracy of 0.22 +/- 0.13 mm at a 70-mm range. In vitro testing showed a resolution of 0.23 +/- 0.11 mm at a range of 75 mm and a resolution of 0.47 +/- 0.47 mm at a range of 97 mm. With combined catheter position and imaging, this tracking method has the potential to replace fluoroscopy and enhance interventional procedures.

[1]  N Danchin,et al.  [Radiodermatitis afer heart catheterization]. , 1999, Presse medicale.

[2]  G. Tupholme Generation of acoustic pulses by baffled plane pistons , 1969 .

[3]  P. Stepanishen Transient Radiation from Pistons in an Infinite Planar Baffle , 1970 .

[4]  Francis Arthur Jenkins,et al.  Fundamentals of Optics , 1976 .

[5]  Keith C. Crandall,et al.  Engineering fundamentals : in measurements, probability, statistics, and dimensions , 1970 .

[6]  J. Jensen,et al.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  P. Stepanishen The Time‐Dependent Force and Radiation Impedance on a Piston in a Rigid Infinite Planar Baffle , 1971 .

[8]  S.W. Smith,et al.  High-speed ultrasound volumetric imaging system. I. Transducer design and beam steering , 1991, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  D. Vilkomerson,et al.  A system for ultrasonic beacon-guidance of catheters and other minimally-invasive medical devices , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  M. D. Morris,et al.  Errors in Practical Measurement in Science, Engineering, and Technology , 1978 .

[11]  S.W. Smith,et al.  High-speed ultrasound volumetric imaging system. II. Parallel processing and image display , 1991, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  Marc D Weinshenker,et al.  Explososcan: a parallel processing technique for high speed ultrasound imaging with linear phased arrays. , 1984 .

[13]  E L Siegel,et al.  Severe skin reactions from interventional fluoroscopy: case report and review of the literature. , 1999, Radiology.

[14]  J A Jensen,et al.  A model for the propagation and scattering of ultrasound in tissue. , 1991, The Journal of the Acoustical Society of America.

[15]  R. E. Davidsen,et al.  Two-Dimensional Random Arrays for Real Time Volumetric Imaging , 1994, Ultrasonic imaging.