Paired self-compensated spin-lock preparation for improved T1ρ quantification.

PURPOSE Spin-lock (SL) imaging allows quantification of the spin-lattice relaxation time in the rotating frame (T1ρ). B0 and B1 inhomogeneities impact T1ρ quantification because the preparatory block in SL imaging is sensitive to the field heterogeneities. Here, a modified preparatory block (PSC-SL) is proposed that attempts to alleviate SL sensitivity to field inhomogeneities in scenarios where existing approaches fail, i.e. high SL frequencies. METHODS Computer simulations, phantom and in vivo experiments were used to determine the effect of field inhomogeneities on T1ρ quantification. Existing SL preparations were compared with PSC-SL in different conditions to assess the advantages and disadvantages of each method. RESULTS Phantom experiments and computer modeling demonstrate that PSC-SL provides superior T1ρ quantification at high SL frequencies in situations where the existing SL preparation methods fail. This result has been confirmed in pre-clinical neuro and body imaging at 7T. CONCLUSION PSC-SL complements existing methods by increasing the accuracy of T1ρ quantification at high spin-lock frequencies when large field inhomogeneities are present. A-priory information about the experimental conditions such, as field distribution and spinlock frequency are useful for selecting an appropriate spin-lock preparation for specific applications.

[1]  J. B. Kneeland,et al.  T1ρ‐relaxation in articular cartilage: Effects of enzymatic degradation , 1997, Magnetic resonance in medicine.

[2]  A. Lamminen,et al.  Spin lock magnetic resonance imaging in the differentiation of hepatic haemangiomas and metastases. , 1995, The British journal of radiology.

[3]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[4]  A. Borthakur,et al.  Estimation of the regional cerebral metabolic rate of oxygen consumption with proton detected 17O MRI during precision 17O2 inhalation in swine , 2009, Journal of Neuroscience Methods.

[5]  S. Meiboom,et al.  NUCLEAR MAGNETIC RESONANCE STUDY OF THE PROTON TRANSFER IN WATER , 1961 .

[6]  Arijitt Borthakur,et al.  Artifacts in T1 rho-weighted imaging: compensation for B(1) and B(0) field imperfections. , 2007, Journal of magnetic resonance.

[7]  J. B. Kneeland,et al.  Proteoglycan‐induced changes in T1ρ‐relaxation of articular cartilage at 4T , 2001, Magnetic resonance in medicine.

[8]  Johannes M. I. H. Gho,et al.  Endogenous assessment of chronic myocardial infarction with T1ρ-mapping in patients , 2014, Journal of Cardiovascular Magnetic Resonance.

[9]  A. Virta,et al.  T1ρ of protein solutions at very low fields: Dependence on molecular weight, concentration, and structure , 1997, Magnetic resonance in medicine.

[10]  H. Aronen,et al.  Spin lock and magnetization transfer imaging of head and neck tumors. , 1996, Radiology.

[11]  P Webb,et al.  Rapid, fully automatic, arbitrary‐volume in vivo shimming , 1991, Magnetic resonance in medicine.

[12]  R. Pettigrew,et al.  Acute myocardial infarction: tissue characterization with T1rho-weighted MR imaging--initial experience. , 2004, Radiology.

[13]  H. Gudbjartsson,et al.  The rician distribution of noisy mri data , 1995, Magnetic resonance in medicine.

[14]  G. Glover,et al.  Rapid in vivo proton shimming , 1991, Magnetic resonance in medicine.

[15]  J. F. Thomson,et al.  Some observations on biological effects of deuterium, with special reference to effects on neoplastic processes. , 1957, Journal of the National Cancer Institute.

[16]  S Majumdar,et al.  In vivo T(1rho) and T(2) mapping of articular cartilage in osteoarthritis of the knee using 3 T MRI. , 2007, Osteoarthritis and cartilage.

[17]  Yuanying Chen,et al.  Rapid evolution of piRNA clusters in the Drosophila melanogaster ovary , 2023, bioRxiv.

[18]  A. Ahuja,et al.  T1rho MR imaging is sensitive to evaluate liver fibrosis: an experimental study in a rat biliary duct ligation model. , 2011, Radiology.

[19]  Weitian Chen,et al.  Quantitative T(1)(ρ) imaging using phase cycling for B0 and B1 field inhomogeneity compensation. , 2011, Magnetic resonance imaging.

[20]  A. Redfield,et al.  Nuclear Magnetic Resonance Saturation and Rotary Saturation in Solids , 1955 .

[21]  R. Gropler,et al.  Cardiac 17O MRI: Toward direct quantification of myocardial oxygen consumption , 2010, Magnetic resonance in medicine.

[22]  S. Koskinen,et al.  T1ρ dispersion of rat tissues in vitro , 1999 .

[23]  R. Pettigrew,et al.  Myocardial suppression in vivo by spin locking with composite pulses , 1996, Magnetic resonance in medicine.

[24]  R M Henkelman,et al.  Spin locking for magnetic resonance imaging with application to human breast , 1989, Magnetic resonance in medicine.

[25]  Timo Liimatainen,et al.  Rotating frame relaxation during adiabatic pulses vs. conventional spin lock: simulations and experimental results at 4 T. , 2009, Magnetic resonance imaging.

[26]  J. Gore,et al.  T1ρ mapping of pediatric epiphyseal and articular cartilage in the knee , 2013, Journal of magnetic resonance imaging : JMRI.

[27]  Sharmila Majumdar,et al.  Simultaneous acquisition of T1ρ and T2 quantification in knee cartilage: Repeatability and diurnal variation , 2014, Journal of magnetic resonance imaging : JMRI.

[28]  J. Pauly,et al.  T1ρ Dispersion in Articular Cartilage , 2015, Cartilage.

[29]  J. B. Kneeland,et al.  Sodium and T 1 r MRI for molecular and diagnostic imaging of articular cartilage y , 2006 .

[30]  R. Jordan,et al.  Rotating-frame relaxation rates of solvent molecules in solutions of paramagnetic ions undergoing solvent exchange , 1984 .

[31]  Arijitt Borthakur,et al.  Artifacts in T(1rho)-weighted imaging: correction with a self-compensating spin-locking pulse. , 2003, Journal of magnetic resonance.

[32]  A. Wand,et al.  Water magnetic relaxation dispersion in biological systems: The contribution of proton exchange and implications for the noninvasive detection of cartilage degradation , 2001, Proceedings of the National Academy of Sciences of the United States of America.

[33]  J. Pilla,et al.  Rotating frame spin lattice relaxation in a swine model of chronic, left ventricular myocardial infarction , 2010, Magnetic resonance in medicine.

[34]  Haosen Zhang,et al.  Feasibility study of myocardial perfusion and oxygenation by noncontrast MRI: comparison with PET study in a canine model. , 2008, Magnetic resonance imaging.

[35]  H J Aronen,et al.  T1ρ dispersion imaging of head and neck tumors: A comparison to spin lock and magnetization transfer techniques , 1997, Journal of magnetic resonance imaging : JMRI.

[36]  Arijitt Borthakur,et al.  Artifacts in T1ρ-weighted imaging: Compensation for B1 and B0 field imperfections , 2007 .

[37]  R. Reddy,et al.  Detection of 17O by Proton T1ρ Dispersion Imaging , 1995 .

[38]  D. Marquardt An Algorithm for Least-Squares Estimation of Nonlinear Parameters , 1963 .

[39]  Ravinder R Regatte,et al.  Proton MRI of metabolically produced H2 17O using an efficient 17O2 delivery system , 2004, NeuroImage.

[40]  Q. Chan,et al.  Quantification of T1ρ relaxation by using rotary echo spin-lock pulses in the presence of B0 inhomogeneity , 2012, Physics in medicine and biology.

[41]  D. Tailor,et al.  Indirect 17O‐magnetic resonance imaging of cerebral blood flow in the rat , 2003 .

[42]  I. Solomon,et al.  ROTARY SPIN ECHOES , 1959 .

[43]  D. Pennell,et al.  Improved MRI R2* relaxometry of iron‐loaded liver with noise correction , 2013, Magnetic resonance in medicine.

[44]  S. Abramson,et al.  T1rho MRI of menisci and cartilage in patients with osteoarthritis at 3T. , 2012, European journal of radiology.

[45]  Michael Garwood,et al.  T1rho MRI contrast in the human brain: modulation of the longitudinal rotating frame relaxation shutter-speed during an adiabatic RF pulse. , 2006, Journal of magnetic resonance.