4D acoustoelectric imaging of current sources in a human head phantom

Electrical brain mapping typically suffers from poor spatial resolution due to the uncertain spread of electric field lines through the brain and skull. To overcome this limitation, we propose 4D acoustoelectric brain imaging (ABI) for mapping current densities at a spatial resolution confined to the ultra-sound (US) focal spot. Acoustoelectric (AE) imaging exploits an interaction between a pressure wave and tissue resistivity. It has been used to dynamically map the cardiac activation wave in the live rabbit heart. Our long-term goal is to extend this technique for electrical mapping of the human brain. In this study, we developed a human-size head and brain phantom to test and optimize ABI for detecting an embedded “EEG-like” electrical current. Detection thresholds for current sources more than 15 mm below the surface of the brain phantom was less than 1 mA/cm2 using a 0.5-MHz or 1 MHz single element transducer and copper recording wires. Further optimization of ABI could enable detection of small neural currents in the brain and lead to a new modality for functional brain imaging.

[1]  Lihong V. Wang,et al.  Acousto-electric tomography , 2004, SPIE BiOS.

[2]  Yexian Qin,et al.  Optimizing frequency and pulse shape for ultrasound current source density imaging , 2012, 2011 IEEE International Ultrasonics Symposium.

[3]  Russell Witte,et al.  Measuring the acoustoelectric interaction constant using ultrasound current source density imaging , 2012, Physics in medicine and biology.

[4]  Jaakko Malmivuo,et al.  Source-Field Models , 1995 .

[5]  D Lehmann,et al.  EEG assessment of brain activity: spatial aspects, segmentation and imaging. , 1984, International journal of psychophysiology : official journal of the International Organization of Psychophysiology.

[6]  D. Tank,et al.  Brain magnetic resonance imaging with contrast dependent on blood oxygenation. , 1990, Proceedings of the National Academy of Sciences of the United States of America.

[7]  Qian Li,et al.  Ultrasound Current Source Density Imaging of the Cardiac Activation Wave Using a Clinical Cardiac Catheter , 2015, IEEE Transactions on Biomedical Engineering.

[8]  J. Krüger,et al.  Simultaneous recording with 30 microelectrodes in monkey visual cortex , 2004, Experimental Brain Research.

[9]  Matthew O'Donnell,et al.  Imaging current flow in lobster nerve cord using the acoustoelectric effect , 2007 .

[10]  Mathieu Pernot,et al.  Ultrafast acoustoelectric imaging , 2014, 2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI).

[11]  Russell S. Witte,et al.  Simulation-based validation for four- dimensional multi-channel ultrasound current source density imaging , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[12]  R. Witte,et al.  Four-dimensional ultrasound current source density imaging of a dipole field. , 2011, Applied physics letters.

[13]  Karl J. Friston,et al.  Cortical areas and the selection of movement: a study with positron emission tomography , 1991, Experimental Brain Research.

[14]  Sheng-Wen Huang,et al.  Cardiac activation mapping using ultrasound current source density imaging (UCSDI) , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  Sheng-Wen Huang,et al.  Ultrasound Current Source Density Imaging , 2008, IEEE Transactions on Biomedical Engineering.

[16]  R. Granit THE HEART ( Extract from “ Principles and Applications of Bioelectric and Biomagnetic Fields , 2005 .

[17]  Karl J. Friston,et al.  Regional cerebral blood flow during voluntary arm and hand movements in human subjects. , 1991, Journal of neurophysiology.

[18]  D. Cohen Magnetoencephalography: Detection of the Brain's Electrical Activity with a Superconducting Magnetometer , 1972, Science.

[19]  G. Blasdel,et al.  Voltage-sensitive dyes reveal a modular organization in monkey striate cortex , 1986, Nature.

[20]  Aiguo Song,et al.  A 3-D Reconstruction Solution to Current Density Imaging Based on Acoustoelectric Effect by Deconvolution: A Simulation Study , 2013, IEEE Transactions on Biomedical Engineering.

[21]  Karl F. Herzfeld,et al.  The Effect of Ultrasonic Waves on the Conductivity of Salt Solutions , 1946 .