[$${}^{11}\hbox {C}$$11C]acetate and PET/CT assessment of muscle activation in rat studies

PurposeThe purpose of the present study is to apply kinetic analysis to investigate exercise-related changes in the metabolism of the skeletal muscle of the rat hindlimb by [$${}^{11}\hbox {C}$$11C]acetate positron emission tomography and computed tomography (PET/CT).MethodsContractions were induced in Wistar rats’ left hindlimb by electrostimulation of the Vastus Lateralis muscle motor point. After 15 min of muscle contractions, [$${}^{11}\hbox {C}$$11C]acetate was injected and PET/CT of both hindlimbs was acquired. The resting hindlimb was used as a control reference. The kinetic parameters $$K_1$$K1 and $$k_2$$k2 were calculated for the target muscles (exercised and control) and correlated with the corresponding standardized uptake values (SUVs). The ratio between each kinetic parameter values and the SUV extracted for the exercised muscle and the muscle at rest was computed ($$K_1^{Ex}/K_1^{Re},\, k_2^{Ex}/k_2^{Re}$$K1Ex/K1Re,k2Ex/k2Re and $$\hbox {SUV}^{Ex}/\hbox {SUV}^{Re}$$SUVEx/SUVRe, respectively).ResultsKinetic analysis quantitatively confirmed that net tracer uptake ($$K_1$$K1) and washout ($$k_2$$k2) were significantly higher in exercised muscles ($$K_1: \,0.34 \pm 0.12 \hbox { min}^{-1}$$K1:0.34±0.12min-1 for exercised muscles vs. $$0.18 \pm 0.09\hbox { min}^{-1}$$0.18±0.09min-1 for resting muscles, $$P=0.01$$P=0.01; $$k_2:\, 0.22 \pm 0.05\hbox { min}^{-1}$$k2:0.22±0.05min-1 for exercised muscle vs. $$0.14 \pm 0.04 \hbox { min}^{-1}$$0.14±0.04min-1 for resting muscle, $$P=0.002$$P=0.002). On the other hand, SUV was not significantly different between active and inactive muscles ($$0.7 \pm 0.2$$0.7±0.2 for exercised muscles vs. $$0.6 \pm 0.1$$0.6±0.1 for resting muscles). Linear regression analysis revealed a good correlation ($$R^2=0.75,\, P=0.005$$R2=0.75,P=0.005) between net tracer uptake ratio ($$K_1^{Ex}/K_1^{Re}$$K1Ex/K1Re) and the SUV ratio $$(\hbox {SUV}^{Ex}/\hbox {SUV}^{Re}$$(SUVEx/SUVRe). A lower correlation was found between the net tracer washout ratio ($$k_2^{Ex}/k_2^{Re}$$k2Ex/k2Re) and the SUV ratio ($$R^2=0.37,\, P=0.1$$R2=0.37,P=0.1).ConclusionThe present study showed that kinetic modelling can detect changes between active and inactive skeletal muscles with a higher sensitivity with respect to the SUV, when performed with [$${}^{11}\hbox {C}$$11C]acetate PET/CT.

[1]  I. Kanno,et al.  Error Analysis of a Quantitative Cerebral Blood Flow Measurement Using H215O Autoradiography and Positron Emission Tomography, with Respect to the Dispersion of the Input Function , 1986, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[2]  H R Schelbert,et al.  Validation of [1-11C]acetate as a tracer for noninvasive assessment of oxidative metabolism with positron emission tomography in normal, ischemic, postischemic, and hyperemic canine myocardium. , 1990, Circulation.

[3]  M Schwaiger,et al.  Effect of carbon-11-acetate recirculation on estimates of myocardial oxygen consumption by PET. , 1991, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[4]  E. Hoffman,et al.  Use of the abdominal aorta for arterial input function determination in hepatic and renal PET studies. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[5]  Zhizhong Wang,et al.  A study on statistically reliable and computationally efficient algorithms for generating local cerebral blood flow parametric images with positron emission tomography , 1993, IEEE Trans. Medical Imaging.

[6]  G J Meyer,et al.  Accurate local blood flow measurements with dynamic PET: fast determination of input function delay and dispersion by multilinear minimization. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[7]  C. Ng,et al.  Validation of a model for [1-11C]acetate as a tracer of cardiac oxidative metabolism. , 1994, The American journal of physiology.

[8]  J. van den Hoff,et al.  A kinetic model for cardiac PET with [1-carbon-11]-acetate. , 1996, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  M E Phelps,et al.  Compartment model for measuring myocardial oxygen consumption using [1-11C]acetate. , 1997, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[10]  M. Phelps,et al.  Simultaneous measurement of myocardial oxygen consumption and blood flow using [1-carbon-11]acetate. , 1998, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[11]  Roger Lecomte,et al.  A microvolumetric blood counter/sampler for metabolic PET studies in small animals , 1998 .

[12]  Sung-Cheng Huang,et al.  Anatomy of SUV , 2000 .

[13]  Robin Hull,et al.  A good practice guide to the administration of substances and removal of blood, including routes and volumes , 2001, Journal of applied toxicology : JAT.

[14]  J van den Hoff,et al.  [1-(11)C]Acetate as a quantitative perfusion tracer in myocardial PET. , 2001, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[15]  Roger Lecomte,et al.  Cardiac Studies in Rats With C-Acetate and PET: A Comparison With N-Ammonia , 2002 .

[16]  Sven N. Reske,et al.  Carbon-11 acetate positron emission tomography can detect local recurrence of prostate cancer , 2002, European Journal of Nuclear Medicine and Molecular Imaging.

[17]  E. Croteau,et al.  Cardiac studies in rats with /sup 11/C-acetate and PET: a comparison with /sup 13/N-ammonia , 2002 .

[18]  N. Sadato,et al.  11C-acetate PET imaging of prostate cancer. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[19]  M. Sacchetti,et al.  Whole body and leg acetate kinetics at rest, during exercise and recovery in humans , 2002, The Journal of physiology.

[20]  Sung-Cheng Huang,et al.  Investigation of a new input function validation approach for dynamic mouse microPET studies. , 2004, Molecular imaging and biology : MIB : the official publication of the Academy of Molecular Imaging.

[21]  Philippe Hantraye,et al.  Arterial input function measurement without blood sampling using a beta-microprobe in rats. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[22]  Osman Ratib,et al.  OsiriX: An Open-Source Software for Navigating in Multidimensional DICOM Images , 2004, Journal of Digital Imaging.

[23]  Ronald Boellaard,et al.  Evaluation of Basis Function and Linear Least Squares Methods for Generating Parametric Blood Flow Images Using 15O-Water and Positron Emission Tomography , 2005, Molecular Imaging and Biology.

[24]  P. Herrero,et al.  Measurement of input functions in rodents: challenges and solutions. , 2005, Nuclear medicine and biology.

[25]  Ranu Jung,et al.  Neuromechanical control of locomotion in the rat. , 2005, Journal of neurotrauma.

[26]  P. Peckham,et al.  Functional electrical stimulation for neuromuscular applications. , 2005, Annual review of biomedical engineering.

[27]  P. Herrero,et al.  Assessment of myocardial blood flow using 15O-water and 1-11C-acetate in rats with small-animal PET. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[28]  Philipp T. Meyer,et al.  Simplified quantification of small animal [18F]FDG PET studies using a standard arterial input function , 2006, European Journal of Nuclear Medicine and Molecular Imaging.

[29]  Roger Lecomte,et al.  A New Tool for Molecular Imaging: The Microvolumetric β Blood Counter , 2007, Journal of Nuclear Medicine.

[30]  R. Fontaine,et al.  A Microvolumetric $\beta$ Blood Counter for Pharmacokinetic PET Studies in Small Animals , 2007, IEEE Transactions on Nuclear Science.

[31]  Kooresh I Shoghi,et al.  Hybrid image and blood sampling input function for quantification of small animal dynamic PET data. , 2007, Nuclear medicine and biology.

[32]  M. Morris,et al.  (11)C-acetate PET imaging in prostate cancer. , 2007, European journal of nuclear medicine and molecular imaging.

[33]  S. Kridel,et al.  1-11C-Acetate as a PET Radiopharmaceutical for Imaging Fatty Acid Synthase Expression in Prostate Cancer , 2008, Journal of Nuclear Medicine.

[34]  Johan Nuyts,et al.  1-11C-Acetate Kinetics of Prostate Cancer , 2008, Journal of Nuclear Medicine.

[35]  James J. Abbas,et al.  Neuromuscular electrical stimulation of the hindlimb muscles for movement therapy in a rodent model , 2009, Journal of Neuroscience Methods.

[36]  J J Abbas,et al.  Neuromuscular stimulation therapy after incomplete spinal cord injury promotes recovery of interlimb coordination during locomotion , 2009, Journal of neural engineering.

[37]  H. Zaidi,et al.  Performance Evaluation of the FLEX Triumph X-PET Scanner Using the National Electrical Manufacturers Association NU-4 Standards , 2010, The Journal of Nuclear Medicine.

[38]  Roger Lecomte,et al.  Image-derived input function in dynamic human PET/CT: methodology and validation with 11C-acetate and 18F-fluorothioheptadecanoic acid in muscle and 18F-fluorodeoxyglucose in brain , 2010, European Journal of Nuclear Medicine and Molecular Imaging.

[39]  Todd E Peterson,et al.  Simplified [18F]FDG Image-Derived Input Function Using the Left Ventricle, Liver, and One Venous Blood Sample , 2010, Molecular imaging.

[40]  Habib Zaidi,et al.  [11C]acetate PET/CT Visualizes Skeletal Muscle Exercise Participation, Impaired Function, and Recovery after Hip Arthroplasty; First Results , 2010, Molecular Imaging and Biology.

[41]  A. Luxen,et al.  Use of a beta microprobe system to measure arterial input function in PET via an arteriovenous shunt in rats , 2011, EJNMMI research.

[42]  E. Croteau,et al.  [11C]Acetate rest-stress protocol to assess myocardial perfusion and oxygen consumption reserve in a model of congestive heart failure in rats. , 2012, Nuclear medicine and biology.

[43]  Y. Kato,et al.  Development of less invasive neuromuscular electrical stimulation model for motor therapy in rodents , 2012, The journal of spinal cord medicine.

[44]  Martin A Lodge,et al.  Dynamic whole-body PET parametric imaging: I. Concept, acquisition protocol optimization and clinical application , 2013, Physics in medicine and biology.

[45]  Rolf Gruetter,et al.  Image-Derived Input Function from the Vena Cava for 18F-FDG PET Studies in Rats and Mice , 2014, The Journal of Nuclear Medicine.

[46]  Kevin M. Brindle,et al.  Imaging Cell Death , 2014, The Journal of Nuclear Medicine.

[47]  Nadia Magnenat-Thalmann,et al.  3D Multiscale Physiological Human , 2014, Springer London.