Light emitting diode excitation emission matrix fluorescence spectroscopy.

An excitation emission matrix (EEM) fluorescence instrument has been developed using a linear array of light emitting diodes (LED). The wavelengths covered extend from the upper UV through the visible spectrum: 370-640 nm. Using an LED array to excite fluorescence emission at multiple excitation wavelengths is a low-cost alternative to an expensive high power lamp and imaging spectrograph. The LED-EEM system is a departure from other EEM spectroscopy systems in that LEDs often have broad excitation ranges which may overlap with neighboring channels. The LED array can be considered a hybrid between a spectroscopic and sensor system, as the broad LED excitation range produces a partially selective optical measurement. The instrument has been tested and characterized using fluorescent dyes: limits of detection (LOD) for 9,10-bis(phenylethynyl)-anthracene and rhodamine B were in the mid parts-per-trillion range; detection limits for the other compounds were in the low parts-per-billion range (< 5 ppb). The LED-EEMs were analyzed using parallel factor analysis (PARAFAC), which allowed the mathematical resolution of the individual contributions of the mono- and dianion fluorescein tautomers a priori. Correct identification and quantitation of six fluorescent dyes in two to six component mixtures (concentrations between 12.5 and 500 ppb) has been achieved with root mean squared errors of prediction (RMSEP) of less than 4.0 ppb for all components.

[1]  J. Sweedler Charge Transfer Device Detectors and Their Applications to Chemical Analysis , 1993 .

[2]  H G Löhmannsröben,et al.  Combination of laser-induced fluorescence and diffuse-reflectance spectroscopy for the in situ analysis of diesel-fuel-contaminated soils. , 1999, Applied optics.

[3]  K. Booksh,et al.  Mitigation of Rayleigh and Raman spectral interferences in multiway calibration of excitation-emission matrix fluorescence spectra. , 2000, Analytical chemistry.

[4]  Oliver C. Mullins,et al.  Gas-Oil Ratio of Live Crude Oils Determined by Near-Infrared Spectroscopy , 2001 .

[5]  C. W. Huie,et al.  Characteristic Visible Fluorescence Emission Spectra of Sera from Cancer Patients , 1994 .

[6]  L. Moberg,et al.  Spectrofluorimetric determination of chlorophylls and pheopigments using parallel factor analysis. , 2001, Talanta.

[7]  M. Moore,et al.  Porphyrin profiles in blood and urine as a biomarker for exposure to various arsenic species. , 2002, Cellular and molecular biology.

[8]  R. Henrion,et al.  Three-way Principal Components Analysis for fluorescence spectroscopic classification of algae species , 1997 .

[9]  J. Callis,et al.  Laser videofluorometer system for real-time characterization of high-performance liquid chromatographic eluate. , 1986, Analytical chemistry.

[10]  K. T. Moesta,et al.  Protoporphyrin IX occurs naturally in colorectal cancers and their metastases. , 2001, Cancer research.

[11]  T Hobo,et al.  Polyester microchannel chip for electrophoresis – incorporation of a blue LED as light source , 2001, Fresenius' journal of analytical chemistry.

[12]  Michael L. Myrick,et al.  Single-Measurement Excitation/Emission Matrix Spectrofluorometer for Determination of Hydrocarbons in Ocean Water. 1. Instrumentation and Background Correction , 1996 .

[13]  P. Smart,et al.  An evaluation of some fluorescent dyes for water tracing , 1977 .

[14]  K. Booksh,et al.  Excitation-emission matrix fluorescence based determination of carbamate pesticides and polycyclic aromatic hydrocarbons , 1999 .

[15]  N. Klonis,et al.  Effect of Solvent–Water Mixtures on the Prototropic Equilibria of Fluorescein and on the Spectral Properties of the Monoanion¶ , 2000 .

[16]  J. S. Woods,et al.  Quantitative determination of porphyrins in rat and human urine and evaluation of urinary porphyrin profiles during mercury and lead exposures. , 1992, The Journal of laboratory and clinical medicine.

[17]  Michael L. Myrick,et al.  Single-Measurement Excitation/Emission Matrix Spectrofluorometer for Determination of Hydrocarbons in Ocean Water. 2. Calibration and Quantitation of Naphthalene and Styrene , 1996 .

[18]  Z. Fang,et al.  A miniaturized liquid core waveguide-capillary electrophoresis system with flow injection sample introduction and fluorometric detection using light-emitting diodes. , 2001, Analytical chemistry.

[19]  J. Morell,et al.  Analysis of the optical properties of the Orinoco River plume by absorption and fluorescence spectroscopy , 1999 .

[20]  G. Albrecht‐Buehler Autofluorescence of live purple bacteria in the near infrared. , 1997, Experimental cell research.

[21]  S. Hart,et al.  A laser-induced fluorescence dual-fiber optic array detector applied to the rapid HPLC separation of polycyclic aromatic hydrocarbons , 2002, Analytical and bioanalytical chemistry.

[22]  A. Baker Fluorescence excitation-emission matrix characterization of river waters impacted by a tissue mill effluent. , 2002, Environmental science & technology.

[23]  J. Callis,et al.  Liquid chromatography with real-time video fluorometric monitoring of effluents , 1981 .

[24]  R. G. Lyons Identification and separation of water tracing dyes using pH response characteristics , 1993 .