Mobile Biplane X-Ray Imaging System for Measuring 3D Dynamic Joint Motion During Overground Gait

Most X-ray fluoroscopy systems are stationary and impose restrictions on the measurement of dynamic joint motion; for example, knee-joint kinematics during gait is usually measured with the subject ambulating on a treadmill. We developed a computer-controlled, mobile, biplane, X-ray fluoroscopy system to track human body movement for high-speed imaging of 3D joint motion during overground gait. A robotic gantry mechanism translates the two X-ray units alongside the subject, tracking and imaging the joint of interest as the subject moves. The main aim of the present study was to determine the accuracy with which the mobile imaging system measures 3D knee-joint kinematics during walking. In vitro experiments were performed to measure the relative positions of the tibia and femur in an intact human cadaver knee and of the tibial and femoral components of a total knee arthroplasty (TKA) implant during simulated overground gait. Accuracy was determined by calculating mean, standard deviation and root-mean-squared errors from differences between kinematic measurements obtained using volumetric models of the bones and TKA components and reference measurements obtained from metal beads embedded in the bones. Measurement accuracy was enhanced by the ability to track and image the joint concurrently. Maximum root-mean-squared errors were 0.33 mm and 0.65° for translations and rotations of the TKA knee and 0.78 mm and 0.77° for translations and rotations of the intact knee, which are comparable to results reported for treadmill walking using stationary biplane systems. System capability for in vivo joint motion measurement was also demonstrated for overground gait.

[1]  E S Grood,et al.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. , 1983, Journal of biomechanical engineering.

[2]  I Söderkvist,et al.  Determining the movements of the skeleton using well-configured markers. , 1993, Journal of biomechanics.

[3]  J. Stiehl,et al.  Fluoroscopic analysis of kinematics after posterior-cruciate-retaining knee arthroplasty. , 1995, The Journal of bone and joint surgery. British volume.

[4]  A Leardini,et al.  Position and orientation in space of bones during movement: experimental artefacts. , 1996, Clinical biomechanics.

[5]  S.A. Banks,et al.  Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy , 1996, IEEE Transactions on Biomedical Engineering.

[6]  Emanuele Trucco,et al.  Introductory techniques for 3-D computer vision , 1998 .

[7]  Scott Tashman,et al.  In vivo measurement of 3-D skeletal kinematics from sequences of biplane radiographs: Application to knee kinematics , 2001, IEEE Transactions on Medical Imaging.

[8]  D. Dennis,et al.  In Vivo Fluoroscopic Analysis of the Normal Human Knee , 2003, Clinical orthopaedics and related research.

[9]  Scott Tashman,et al.  In-vivo measurement of dynamic joint motion using high speed biplane radiography and CT: application to canine ACL deficiency. , 2003, Journal of biomechanical engineering.

[10]  Bart L Kaptein,et al.  Marker Configuration Model-Based Roentgen Fluoroscopic Analysis. , 2005, Journal of biomechanics.

[11]  Guoan Li,et al.  An optimized image matching method for determining in-vivo TKA kinematics with a dual-orthogonal fluoroscopic imaging system. , 2006, Journal of biomechanical engineering.

[12]  Gábor Székely,et al.  Three-dimensional kinematics and kinetics of total knee arthroplasty during level walking using single plane video-fluoroscopy and force plates: a pilot study. , 2006, Gait & posture.

[13]  M G Pandy,et al.  Integrating modelling and experiments to assess dynamic musculoskeletal function in humans , 2006, Experimental physiology.

[14]  R. Balderston,et al.  Evaluation of Spinal Kinematics Following Lumbar Total Disc Replacement and Circumferential Fusion Using In Vivo Fluoroscopy , 2007 .

[15]  S. Tashman,et al.  Dynamic Function of the ACL-reconstructed Knee during Running , 2007, Clinical orthopaedics and related research.

[16]  W. A. Hodge,et al.  An in vivo model for intraoperative assessment of impingement and dislocation in total hip arthroplasty. , 2008, The Journal of arthroplasty.

[17]  S. Banks,et al.  Determination of in vivo glenohumeral translation using fluoroscopy and shape-matching techniques. , 2008, Journal of shoulder and elbow surgery.

[18]  Guoan Li,et al.  Validation of a non-invasive fluoroscopic imaging technique for the measurement of dynamic knee joint motion. , 2008, Journal of biomechanics.

[19]  Karen O. Egiazarian,et al.  Image restoration by sparse 3D transform-domain collaborative filtering , 2008, Electronic Imaging.

[20]  M G Pandy,et al.  Integrating modelling, motion capture and x-ray fluoroscopy to investigate patellofemoral function during dynamic activity , 2008, Computer methods in biomechanics and biomedical engineering.

[21]  D. Winter Appendix A: Kinematic, Kinetic, and Energy Data , 2009 .

[22]  Scott Tashman,et al.  Validation of three-dimensional model-based tibio-femoral tracking during running. , 2009, Medical engineering & physics.

[23]  Fang Liu,et al.  Tibiofemoral kinematics and condylar motion during the stance phase of gait. , 2009, Journal of biomechanics.

[24]  S. Banks,et al.  Ankle and Subtalar Kinematics during Dorsiflexion-Plantarflexion Activities , 2009, Foot & ankle international.

[25]  Anthony G Schache,et al.  Non-invasive assessment of soft-tissue artifact and its effect on knee joint kinematics during functional activity. , 2010, Journal of biomechanics.

[26]  M G Pandy,et al.  Future trends in the use of X-ray fluoroscopy for the measurement and modelling of joint motion , 2011, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[27]  K. Shelburne,et al.  A comparison of calibration methods for stereo fluoroscopic imaging systems. , 2011, Journal of biomechanics.

[28]  H. Menz,et al.  Knee kinematics during walking at different speeds in people who have undergone total knee replacement. , 2010, The Knee.

[29]  Guoan Li,et al.  The accuracy and repeatability of an automatic 2D-3D fluoroscopic image-model registration technique for determining shoulder joint kinematics. , 2012, Medical engineering & physics.

[30]  J. Goldhahn,et al.  Three-Dimensional Kinematics of an Unconstrained Ankle Arthroplasty: A Preliminary In Vivo Videofluoroscopic Feasibility Study , 2012, Foot & ankle international.

[31]  J Erik Giphart,et al.  Accuracy of a contour-based biplane fluoroscopy technique for tracking knee joint kinematics of different speeds. , 2012, Journal of biomechanics.

[32]  S. Woo,et al.  In Vivo Tibiofemoral Kinematics During 4 Functional Tasks of Increasing Demand Using Biplane Fluoroscopy , 2012, The American journal of sports medicine.

[33]  M. Pandy,et al.  Muscle function during gait is invariant to age when walking speed is controlled. , 2013, Gait & posture.

[34]  Justin W. Fernandez,et al.  Subject-specific evaluation of patellofemoral joint biomechanics during functional activity. , 2014, Medical engineering & physics.

[35]  James D. Kang,et al.  Continuous cervical spine kinematics during in vivo dynamic flexion-extension. , 2014, The spine journal : official journal of the North American Spine Society.