Force-assisted ultrasound imaging system through dual force sensing and admittance robot control

PurposeUltrasound imaging has been a gold standard for clinical diagnoses due to its unique advantages compared to other imaging modalities including: low cost, noninvasiveness, and safeness to the human body. However, the ultrasound scanning process requires applying a large force over extended periods of time, often in uncomfortable postures in order to maintain the desired orientation. This physical requirement over sonographers’ careers often leads to musculoskeletal pain and strain injuries.MethodsTo address this problem, we propose a cooperatively controlled robotic ultrasound system to reduce the force sonographers apply. The proposed system consists of two key components: a six-axis robotic arm that holds and actuates the ultrasound probe, and a dual force sensor setup that enables cooperative control and adaptive force assistance. With the admittance force control, the robotic arm complies with the motion of the operator, while assisting with force during the scanning.ResultsWe validated the system through a user study involving expert sonographers and lay people and demonstrated 32–73% reduction in human applied force and 8– 18% improvement in image stability.ConclusionThese results indicate that the system has the potential to not only reduce the burden on the sonographer, but also provide more stable ultrasound scanning.

[1]  A. M. Priester,et al.  Robotic ultrasound systems in medicine , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  Emad M. Boctor,et al.  High resolution three-dimensional robotic synthetic tracked aperture ultrasound imaging: feasibility study , 2017, Medical Imaging.

[3]  A. Smith,et al.  Musculoskeletal pain in cardiac ultrasonographers: results of a random survey. , 1997, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[4]  C. J. Zandsteeg,et al.  Haptic tele-operation system control design for the ultrasound task: A loop-shaping approach , 2010 .

[5]  Kyrre Glette,et al.  An Ultrasound Robotic System Using the Commercial Robot UR5 , 2016, Front. Robot. AI.

[6]  Gregg E. Trahey,et al.  Synthetic tracked aperture ultrasound imaging: design, simulation, and experimental evaluation , 2016, Journal of medical imaging.

[7]  Russell H. Taylor,et al.  Micro-force Sensing in Robot Assisted Membrane Peeling for Vitreoretinal Surgery , 2010, MICCAI.

[8]  Russell H. Taylor,et al.  A multi-function force sensing instrument for variable admittance robot control in retinal microsurgery , 2014, 2014 IEEE International Conference on Robotics and Automation (ICRA).

[9]  Wen-Hong Zhu,et al.  A Robot System for Medical Ultrasound , 2000 .

[10]  Matthew W. Gilbertson,et al.  An ergonomic, instrumented ultrasound probe for 6-axis force/torque measurement , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[11]  Thomas Neff,et al.  Towards MRI-Based Autonomous Robotic US Acquisitions: A First Feasibility Study , 2016, IEEE Transactions on Medical Imaging.

[12]  J. Goverman,et al.  Transducer user syndrome: an occupational hazard of the ultrasonographer. , 1999, European journal of ultrasound : official journal of the European Federation of Societies for Ultrasound in Medicine and Biology.

[13]  Mamoru Mitsuishi,et al.  Construction Methodology for a Remote Ultrasound Diagnostic System , 2009, IEEE Transactions on Robotics.

[14]  Russell H. Taylor,et al.  A constrained optimization approach to virtual fixtures , 2005, 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[15]  Haichong K. Zhang,et al.  Co-robotic synthetic tracked aperture ultrasound imaging with cross-correlation based dynamic error compensation and virtual fixture control , 2016, 2016 IEEE International Ultrasonics Symposium (IUS).

[16]  Peter Kazanzides,et al.  Cooperative Control with Ultrasound Guidance for Radiation Therapy , 2016, Front. Robot. AI.

[17]  Nicolas Roussel,et al.  1 € filter: a simple speed-based low-pass filter for noisy input in interactive systems , 2012, CHI.