Wireless Batteryless Implantable Blood Pressure Monitoring Microsystem for Small Laboratory Animals

A novel, wireless, batteryless, implantable blood pressure monitoring microsystem for small laboratory animals is developed for advanced biological and system biology research. The system employs an instrumented elastic circular cuff, wrapped around a blood vessel, for real-time blood pressure monitoring. The elastic circular cuff is made of soft bio-compatible silicone material, which is filled with bio-compatible insulating fluid with an immersed microelectromechanical systems (MEMS) pressure sensor and integrated electronic system to detect a down-scaled vessel blood pressure waveform. This technique avoids vessel penetration and substantially minimizes vessel restriction due to the soft cuff elasticity, thus attractive for long-term monitoring. A large-model engineering experiment is first developed to verify and demonstrate the concept. A miniature prototype monitoring cuff is then fabricated and implanted in two laboratory rats to evaluate its functionality. A wireless and batteryless monitoring microsystem is then implanted and characterized in a laboratory rat. The measured in vivo blood pressure waveform by the microsystem and a reference waveform recorded by a commercial catheter-tip transducer are closely matched in shape with a constant scaling factor, demonstrating a blood pressure signal with high fidelity can be wirelessly obtained by the implantable monitoring microsystem. The overall implant dissipates 300 ¿W, which is powered by an external adaptive RF powering source.

[1]  Marc M. Budge,et al.  Terminology for Describing the Elastic Behavior of Arteries , 2003 .

[2]  D.J. Young,et al.  2 GHz CMOS Voltage-Controlled Oscillator with Optimal Design of Phase Noise and Power Dissipation , 2007, 2007 IEEE Radio Frequency Integrated Circuits (RFIC) Symposium.

[3]  F L Wuyts,et al.  Elastic properties of human aortas in relation to age and atherosclerosis: a structural model. , 1995, Physics in medicine and biology.

[4]  D.J. Young,et al.  Adaptive RF power control for wireless implantable bio-sensing network to monitor untethered laboratory animal real-time biological signals , 2008, 2008 IEEE Sensors.

[5]  Wen H. Ko,et al.  Touch mode capacitive pressure sensors , 1999 .

[6]  Yoh-Han Pao,et al.  Naturally occurring variation in cardiovascular traits among inbred mouse strains. , 2002, Genomics.

[7]  R S Reneman,et al.  Aortic wall properties in normotensive and hypertensive rats of various ages in vivo. , 1995, Hypertension.

[8]  Peng Cong,et al.  Implantable blood pressure monitoring of small animal for advanced biological research , 2005, The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05..

[9]  D.J. Young,et al.  Wireless less-invasive blood pressure sensing microsystem for small laboratory animal in vivo real-time monitoring , 2008, 2008 5th International Conference on Networked Sensing Systems.

[10]  Darrin J. Young,et al.  Low noise μWatt interface circuits for wireless implantable real-time digital blood pressure monitoring , 2008, 2008 IEEE Custom Integrated Circuits Conference.

[11]  B P Brockway,et al.  A new method for continuous chronic measurement and recording of blood pressure, heart rate and activity in the rat via radio-telemetry. , 1991, Clinical and experimental hypertension. Part A, Theory and practice.

[12]  W. Ko,et al.  Novel Long-Term Implantable Blood Pressure Monitoring System with Reduced Baseline Drift , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[13]  Jiangang Du,et al.  High-temperature single-crystal 3C-SiC capacitive pressure sensor , 2004, IEEE Sensors Journal.

[14]  S. Whitesall,et al.  Comparison of simultaneous measurement of mouse systolic arterial blood pressure by radiotelemetry and tail-cuff methods. , 2004, American journal of physiology. Heart and circulatory physiology.