Multi-criterion optimization of building envelope in the function of indoor illumination quality towards overall energy performance improvement

This paper elaborates the formulation and application of an integral methodology for overall energy performance improvement of office buildings and demonstrates its application. The developed multi-objective methodology is demonstrated on a reference office building located in a temperate climate zone with high annual temperature variations. The idea is to formulate a research based proposition in building science with a formulation of a general/integral methodology which could be applied widely in energy performance refurbishment of existing office buildings and help architects and engineers in the early-design stages of new projects. The goal was to formulate an optimized building envelope model using multi-criterion optimization methodology in order to determine efficient window to wall ratio (WWR) and window geometry (WG) in the function of indoor illumination quality, followed by the assessment of glazing parameters influence on the annual energy demand. The integral methodology for overall energy performance improvement of office buildings utilizes multi-criterion optimization method and highly detailed Building Information Modeling (BIM) programs and dynamic energy simulation engines. The developed coupled-integral methodology links together both building envelope construction optimization and user comfort. The methodology is both flexible and adaptable for application in various climatic conditions and for different construction types.

[1]  Dj Carter,et al.  The costs and benefits of using daylight guidance to light office buildings , 2011 .

[2]  Jeong Tai Kim,et al.  Tuning control of buildings glazing's transmittance dependence on the solar radiation wavelength to optimize daylighting and building's energy efficiency , 2013 .

[3]  Eui-Jong Kim,et al.  Urban energy simulation: Simplification and reduction of building envelope models , 2014 .

[4]  Burcin Becerik-Gerber,et al.  A model calibration framework for simultaneous multi-level building energy simulation , 2015 .

[5]  Ralph Evins,et al.  Multi-level optimization of building design, energy system sizing and operation , 2015 .

[6]  Aleksandra Krstić-Furundžić,et al.  Assessment of energy and environmental performance of office building models: A case study , 2016 .

[7]  Lin-Shu Wang,et al.  Maximum window-to-wall ratio of a thermally autonomous building as a function of envelope U-value and ambient temperature amplitude , 2015 .

[8]  Salvatore Carlucci,et al.  Assessing gaps and needs for integrating building performance optimization tools in net zero energy buildings design , 2013 .

[9]  B. Olesen Indoor environmental input parameters for the design and assessment of energy performance of buildings , 2015 .

[10]  Danny H.W. Li,et al.  A review of daylight illuminance determinations and energy implications , 2010 .

[11]  Zoltán Nagy,et al.  Balancing envelope and heating system parameters for zero emissions retrofit using building sensor data , 2014 .

[12]  Rahman Azari Integrated energy and environmental life cycle assessment of office building envelopes , 2014 .

[13]  Mario Sassone,et al.  The early design stage of a building envelope: Multi-objective search through heating, cooling and lighting energy performance analysis , 2015 .

[14]  Zoltán Magyar,et al.  ENERGY PERFORMANCE MODELLING AND HEAT RECOVERY UNIT EFFICIENCY ASSESSMENT OF AN OFFICE BUILDING , 2014 .

[15]  Ilknur Turkseven Dogrusoy,et al.  A field study on determination of preferences for windows in office environments , 2007 .

[16]  Matthias Haase,et al.  Optimizing the configuration of a façade module for office buildings by means of integrated thermal and lighting simulations in a total energy perspective , 2013 .

[17]  Leidy E. Klotz,et al.  A framework for sustainable whole systems design , 2012 .

[18]  Eike Musall,et al.  Zero Energy Building A review of definitions and calculation methodologies , 2011 .

[19]  Kyle Konis,et al.  Evaluating daylighting effectiveness and occupant visual comfort in a side-lit open-plan office building in San Francisco, California , 2013 .

[20]  Carlos Ernesto Ochoa,et al.  Simulation-based method to determine climatic energy strategies of an adaptable building retrofit façade system , 2014 .

[21]  Dušan Gvozdenac,et al.  Serbian energy efficiency problems , 2014 .