Atropine-selective membrane electrodes and relative selectivity concept.

TFPB was introduced as a charged ionophore for atropine selective electrodes. Typical Nernstian responses were found (57.78, 58.95 and 58.41 mV/decade) for PVC-membrane electrodes incorporating NPOE, DOS, and DDP as plasticizers. They exhibited practical linear ranges of 9.1 x 10(-3) - 10(-6), 9.1 x 10(-3) - 10(-6) and 9.1 x 10(-3) - 10(-7) M, respectively. It works in the sub-micro scale of atropine concentrations. The optimum pH-range was 3.18 - 8.97. The selectivity coefficient values were estimated for different organic and inorganic cations. They were interpreted by using the "Relative Selectivity Concept", which was introduced for the first time. The new concept was applied for comparing the selectivity properties of previously reported electrodes. The effect of the presence of ephedrine, caffeine, glucose, Na(+), Ca(2+), and Mg(2+) on the calibration graphs of the electrodes was studied.

[1]  A. Pandey,et al.  Determination and theoretical evaluation of selectivity coefficients of monovalent anions in anion-exchange polymer inclusion membrane , 2007 .

[2]  L. Bachas,et al.  Nitrate-selective electrode based on a cyclic bis-thiourea ionophore , 2007 .

[3]  U. Holzgrabe,et al.  Analysis of atropine, its degradation products and related substances of natural origin by means of reversed-phase high-performance liquid chromatography. , 2004, Journal of chromatography. A.

[4]  M. Shibata,et al.  Studies on the Matched Potential Method for Determining the Selectivity Coefficients of Ion-Selective Electrodes Based on Neutral Ionophores: Experimental and Theoretical Verification , 2001, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[5]  S. Khalil,et al.  Indirect atomic absorption determination of atropine, diphenhydramine, tolazoline, and levamisole based on formation of ion-associates with potassium tetraiodometrcurate. , 2001, Journal of pharmaceutical and biomedical analysis.

[6]  Qingji Xie,et al.  Development of a new atropine sulfate bulk acoustic wave sensor based on a molecularly imprinted electrosynthesized copolymer of aniline with o-phenylenediamine , 2000 .

[7]  Wei Zhang,et al.  Comparison of different methods for determining the selectivity coefficient using a magnesium-selective electrode , 1998 .

[8]  E. Bakker Selectivity comparison of neutral carrier-based ion-selective optical and potentiometric sensing schemes , 1997 .

[9]  C. Maccà Determination of potentiometric selectivity , 1996 .

[10]  J. Lima,et al.  Construction and Evaluation of Atropine Selective Electrodes. Their Application to Ophthalmic Formulations , 1994 .

[11]  T. Imato,et al.  Vitamin B1 sensitive poly(vinyl chloride) membrane electrode based on hydrophobic tetraphenylborate derivatives and their application , 1990 .

[12]  S. Hassan,et al.  Liquid and poly(vinyl chloride) atropine-reineckate membrane electrodes for determination of atropine. , 1984, Analytical chemistry.

[13]  G. Christian,et al.  Determination of selectivity coefficients of ion-selective electrodes by a matched-potential method , 1984 .

[14]  A. Hulanicki,et al.  Selectivity coefficient changes for liquid-membrane electrodes , 1975 .

[15]  R. Hatcher THE UNITED STATES PHARMACOPEIA. , 1908 .