Potentiometric biosensors for cholinesterase inhibitor analysis based on mediatorless bioelectrocatalysis.

A potentiometric method for cholinesterase inhibitor analysis based on mediatorless bioelectrocatalysis has been developed. The method includes coimmobilization of three enzymes, butyrylcholinesterase, choline oxidase and peroxidase, on composite carbon electrodes. Catalytic hydrolysis of butyrylcholine and subsequent catalytic oxidation of choline result in the formation of hydrogen peroxide leads to a shift in the electrode potential. The detection limit for trichlorfon analysis is 2 x 10(-13) M. Electrodes remain stable for at least 4 weeks when stored at 277 K.

[1]  J. Káš,et al.  Determination of phospholipase D activity with a choline biosensor , 1993 .

[2]  A. Ghindilis,et al.  Glucose potentiometric electrodes based on mediatorless bioelectrocatalysis. A new approach. , 1994, Biosensors & bioelectronics.

[3]  T. Kayamoto,et al.  Determination of cholinesterase in blood serum with a benzoate-sensitive membrane electrode , 1991 .

[4]  K. Okumura,et al.  Application of a coated-wire electrode to an acetylcholine sensor , 1990 .

[5]  S. Babkina,et al.  An enzyme amperometric sensor for toxicant determination , 1991 .

[6]  W. Göpel,et al.  Biosensors for choline, choline esters and inhibitors of choline esterase , 1991 .

[7]  P. Coulet,et al.  Rapid and sensitive discriminating determination of acetylcholinesterase activity in amniotic fluid with a choline sensor. , 1991, Clinica chimica acta; international journal of clinical chemistry.

[8]  M. Mascini,et al.  AMPEROMETRIC ACETYLCHOLINE AND CHOLINE SENSORS WITH IMMOBILIZED ENZYMES , 1986 .

[9]  T. Yao Flow injection analysis for cholinesterase in blood serum by use of a choline-sensitive electrode as an amperometric detector , 1983 .

[10]  Félix Pariente,et al.  Determination of organophosphorus and carbamic pesticides with an acetylcholinesterase amperometric biosensor using 4-aminophenyl acetate as substrate , 1994 .

[11]  H. Girault,et al.  Determination of butyrylcholinesterase inhibition using ion transfer across the interface between two immiscible liquids , 1994 .

[12]  Nicole Jaffrezic-Renault,et al.  Sensitive detection of pesticides using a differential ISFET-based system with immobilized cholinesterases , 1993 .

[13]  J. Kulys,et al.  BIENZYME SENSORS BASED ON CHEMICALLY MODIFIED ELECTRODES , 1991 .

[14]  Jean-Louis Marty,et al.  Acetylcholinesterase in organic solvents for the detection of pesticides: Biosensor application , 1994 .

[15]  P C Pandey,et al.  Studies on acetylcholine sensor and its analytical application based on the inhibition of cholinesterase. , 1990, Biosensors & bioelectronics.

[16]  C Cremisini,et al.  Anticholinesterase activity measurement by a choline biosensor: application in water analysis. , 1993, Biosensors & bioelectronics.

[17]  Mustafaev Mi,et al.  [Complex formation of copolymers of 4-vinylpyridine and 4-vinyl-cetylpyridinium bromide with serum albumin]. , 1975 .

[18]  A. Michael,et al.  Amperometric sensors for peroxide, choline, and acetylcholine based on electron transfer between horseradish peroxidase and a redox polymer. , 1993, Analytical chemistry.

[19]  Andrey Bratov,et al.  Enzyme semiconductor sensor based on butyrylcholinesterase , 1991 .