Novel Smart Glove Technology as a Biomechanical Monitoring Tool

Developments in Virtual Reality (VR) technology and its overall market have been occurring since the 1960s when Ivan Sutherland created the world’s first tracked head-mounted display (HMD) – a goggle type head gear. In society today, consumers are expecting a more immersive experience and associated tools to bridge the cyber-physical divide. This paper presents the development of a next generation smart glove microsystem to facilitate Human Computer Interaction through the integration of sensors, processors and wireless technology. The objective of the glove is to measure the range of hand joint movements, in real time and empirically in a quantitative manner. This includes accurate measurement of flexion, extension, adduction and abduction of the metacarpophalangeal (MCP), Proximal interphalangeal (PIP) and Distal interphalangeal (DIP) joints of the fingers and thumb in degrees, together with thumb-index web space movement. This system enables full real-time monitoring of complex hand movements. Commercially available gloves are not fitted with sufficient sensors for full data capture, and require calibration for each glove wearer. Unlike these current state-of-the-art data gloves, the UU / Tyndall Inertial Measurement Unit (IMU) glove uses a combination of novel stretchable substrate material and 9 degree of freedom (DOF) inertial sensors in conjunction with complex data analytics to detect joint movement. Our novel IMU data glove requires minimal calibration and is therefore particularly suited to multiple application domains such as Human Computer interfacing, Virtual reality, the healthcare environment. Copyright © 2015 IFSA Publishing, S. L.

[1]  Brendan O'Flynn,et al.  Integrated Smart Glove for Hand Motion Monitoring , 2015 .

[2]  J. Drace,et al.  Evaluation of a fiber optic glove for semi-automated goniometric measurements. , 1990, Journal of rehabilitation research and development.

[3]  Noureddine Manamanni,et al.  Position estimation approach by Complementary Filter-aided IMU for indoor environment , 2013, 2013 European Control Conference (ECC).

[4]  Kang Li,et al.  Development of finger-motion capturing device based on optical linear encoder. , 2011, Journal of rehabilitation research and development.

[5]  R. J. Johns,et al.  Quantitative and Qualitative Analysis of Joint Stiffness in Normal Subjects and in Patients with Connective Tissue Diseases *† , 1961, Annals of the rheumatic diseases.

[6]  H. Holman,et al.  Measurement of patient outcome in arthritis. , 1980, Arthritis and rheumatism.

[7]  W. Tharion,et al.  Interrater and intrarater reliability of finger goniometric measurements. , 2010, The American journal of occupational therapy : official publication of the American Occupational Therapy Association.

[8]  Derek G. Kamper,et al.  A low cost instrumented glove for extended monitoring and functional hand assessment , 2007, Journal of Neuroscience Methods.

[9]  J. Fries,et al.  The dimensions of health outcomes: the health assessment questionnaire, disability and pain scales. , 1982, The Journal of rheumatology.

[10]  M. Ingpen,et al.  A simple apparatus for assessment of stiffness. , 1968, Annals of physical medicine.

[11]  M. Dougados,et al.  Early referral recommendation for newly diagnosed rheumatoid arthritis: evidence based development of a clinical guide , 2002, Annals of the rheumatic diseases.

[12]  D. Hose,et al.  A Goniometric Glove for Clinical Hand Assessment , 2000, Journal of hand surgery.

[13]  Kevin Curran,et al.  Novel smart sensor glove for arthritis rehabiliation , 2013, 2013 IEEE International Conference on Body Sensor Networks.

[14]  Greg Welch,et al.  HISTORY: The Use of the Kalman Filter for Human Motion Tracking in Virtual Reality , 2009, PRESENCE: Teleoperators and Virtual Environments.

[15]  F. A. Hellebrandt,et al.  The Measurement of Joint Motion: Part III—Reliability of Goniometry , 1949 .

[16]  J. Scott Morning Stiffness in Rheumatoid Arthritis * , 1960, Annals of the rheumatic diseases.

[17]  Joseph Classen,et al.  Development and evaluation of a low-cost sensor glove for assessment of human finger movements in neurophysiological settings , 2009, Journal of Neuroscience Methods.

[18]  Lisa K Simone,et al.  Design considerations for a wearable monitor to measure finger posture , 2005, Journal of NeuroEngineering and Rehabilitation.

[19]  A. Unsworth,et al.  Measurement of stiffness in the metacarpophalangeal joint: the arthrograph. , 1982, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[20]  M. A. van 't Hof,et al.  Development of a disease activity score based on judgment in clinical practice by rheumatologists. , 1993, The Journal of rheumatology.

[21]  P. Dario,et al.  Evaluation of an instrumented glove for hand-movement acquisition. , 2003, Journal of rehabilitation research and development.

[22]  N. Wachter,et al.  [Reproducibility of measuring the finger joint angle with a sensory glove]. , 2001, Handchirurgie, Mikrochirurgie, Plastische Chirurgie.

[23]  Giovanni Saggio,et al.  A novel application method for wearable bend sensors , 2009, 2009 2nd International Symposium on Applied Sciences in Biomedical and Communication Technologies.

[24]  R. Meals,et al.  Proximal interphalangeal joint stiffness: measurement and analysis. , 2005, The Journal of hand surgery.

[25]  V. Wright,et al.  Reference values for metacarpophalangeal joint stiffness in normals. , 1985, Annals of the rheumatic diseases.

[26]  M. Liang,et al.  The American Rheumatism Association 1987 revised criteria for the classification of rheumatoid arthritis. , 1988, Arthritis and rheumatism.