Optimal structural analysis with associated passive heat removal for AP1000 shield building

Abstract The shield building of AP1000 was designed to protect the steel containment vessel (CV) of nuclear power plants. When the reactor is shutdown, the tank mounted above the shield building sprays water, and the intake of ambient air cools down the temperature of CV through buoyancy driven circulation. The result of heat transfer analysis indicates that the location of air intake at lower altitude is more effective than that in the original design. However, pursuing superior heat transfer may cause a conflict with the structural strength, particularly under the threat of an earthquake. Therefore, this study identified the optimal design for stress analysis to improve passive cooling. The results of structural analyses indicated that the maximal stresses developed under various water levels were in the acceptable range of yield stress limits for concrete. The water level does not pose considerable danger to the structure. In addition, the simulation result also indicated that an optimal parametric design for air intake must be implemented around the middle of the shield building, with 16 circular or oval shaped air intake.

[1]  T. Hung,et al.  Effects of Thermal Radiation for Electronic Cooling on Modified PCB Geometry under Natural Convection , 2007 .

[2]  G. H. Su,et al.  Analysis of safety margin of in-vessel retention for AP1000 , 2010 .

[3]  R. Mises Mechanik der festen Körper im plastisch- deformablen Zustand , 1913 .

[4]  B. Launder,et al.  Lectures in mathematical models of turbulence , 1972 .

[5]  T. Hung A CONCEPTUAL DESIGN OF THERMAL MODELING FOR EFFICIENTLY COOLING AN ARRAY OF HEATED , 2001 .

[6]  T. Hung,et al.  Conjugate Heat Transfer Analysis for the Passive Enhancement of Electronic Cooling Through Geometric Modification in a Mixed Convection Domain , 1999 .

[7]  T. L. Schulz,et al.  Westinghouse AP1000 advanced passive plant , 2006 .

[8]  D. Logan A First Course in the Finite Element Method , 2001 .

[9]  Edward L. Wilson,et al.  Finite elements for the dynamic analysis of fluid‐solid systems , 1983 .

[10]  Luis E. Herranz,et al.  A diffusion layer model for steam condensation within the AP600 containment , 1998 .

[11]  B. Launder,et al.  The numerical computation of turbulent flows , 1990 .

[12]  Heiner Igel,et al.  Characteristics of amplitude and duration for near fault strong ground motion from the 1999 Chi-Chi, Taiwan Earthquake , 2002 .

[13]  T. C. Hung,et al.  CFD modeling and thermal-hydraulic analysis for the passive decay heat removal of a sodium-cooled fast reactor , 2011 .

[14]  J. Wolf Soil-structure-interaction analysis in time domain , 1988 .

[15]  Anil K. Chopra,et al.  Dynamics of Structures: Theory and Applications to Earthquake Engineering , 1995 .

[16]  Temel Türker,et al.  Effect of the model updating on the earthquake behavior of steel storage tanks , 2010 .

[17]  Nathan M. Newmark,et al.  A Method of Computation for Structural Dynamics , 1959 .

[18]  Tzu-Chen Hung,et al.  An optimal parametric design to improve chip cooling , 2007 .

[19]  Joon-Hyung Cho,et al.  Finite element techniques for the free-vibration and seismic analysis of liquid-storage tanks , 2001 .

[20]  R. Livaoğlu,et al.  Simplified seismic analysis procedures for elevated tanks considering fluid–structure–soil interaction , 2006 .

[21]  Prediction of radiative transfer in general body-fitted coordinates , 1997 .

[22]  Richard S. Orr,et al.  Finite element modeling of the AP1000 nuclear island for seismic analyses at generic soil and rock sites , 2007 .

[23]  Wenxiang Zhou,et al.  Numerical Analysis of Turbulent Heat Transfer and Flow through Mixing Split Vane in a Sub-channel of AP1000 Nuclear Reactor , 2012 .

[24]  Wei Wang,et al.  Thermal hydraulic phenomena related to small break LOCAs in AP1000 , 2011 .