Understanding automatic generation control

The authors describe what automatic generation control (AGC) might be expected to do, and what may not be possible or expedient for it to do. The purposes and objectives of AGC are limited by physical elements involved in the process and, hence, the relevant characteristics of these elements are described. For reasons given, it is desired that AGC act slowly and deliberately over tens of seconds or a few minutes. From a perspective of utility operations, there is no particular economic or control purpose served by speeding up the AGC action. >

[1]  R. P. Schulte,et al.  Modified automatic time error control and inadvertent interchange reduction for the WSCC interconnected power systems , 1991 .

[2]  T. Kennedy,et al.  Variable, nonlinear tie-line frequency bias for interconnected systems control , 1988 .

[3]  Karl Eklund,et al.  A Simplified Nonlinear Model of a Drum Boiler-Turbine Unit , 1972 .

[4]  C. Concordia Power System Objectives' Side Effects: Good and Bad , 1990, IEEE Power Engineering Review.

[5]  J. Carpentier,et al.  ‘To be or not to be modern’ that is the question for automatic generation control (point of view of a utility engineer) , 1985 .

[6]  N. Cohn,et al.  Cost aspects of AGC, inadvertent energy and time error , 1990 .

[7]  Charles E. Fosha,et al.  The Megawatt-Frequency Control Problem: A New Approach Via Optimal Control Theory , 1970 .

[8]  M. L. Kothari,et al.  Discrete-Mode Automatic Generation Control of a Two-Area Reheat Thermal System with New Area Control Error , 1989, IEEE Power Engineering Review.

[9]  Thomas Kennedy,et al.  Interrelationship of Time Error, Frequency Deviation, and Inadvertent Flow on an Interconnected System , 1968 .

[10]  N. P. Mueller Response of Pressurized Water Reactors to Network Power Generation Demands , 1982, IEEE Transactions on Power Apparatus and Systems.

[11]  A. Klopfenstein Response of Steam and Hydroelectric Generating Plants to Generation Control Tests , 1959, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.

[12]  R. Schlueter,et al.  Inertial, Governor, And Agc/Economic Dispatch Load Flow Simulations Of Loss Of Generation Contingencies , 1985, IEEE Transactions on Power Apparatus and Systems.

[13]  Anjan Bose,et al.  Regulation Error in Load Frequency Control , 1980, IEEE Transactions on Power Apparatus and Systems.

[14]  T. S. Bhatti,et al.  Sampled Data Automatic Generation Control Analysis with Reheat Steam Turbines and Governor Dead-Band Effects , 1984, IEEE Power Engineering Review.

[15]  Nasser Jaleeli,et al.  A Comprehensive Shakedown of an Automatic Generation Control Process , 1989, IEEE Power Engineering Review.

[16]  Charles E. Fosha,et al.  Optimum Megawatt-Frequency Control of Multiarea Electric Energy Systems , 1970 .

[17]  R.D. Dunlop,et al.  System requirements for dynamic performance and response of generating units , 1975, IEEE Transactions on Power Apparatus and Systems.

[18]  C. Taylor,et al.  Automatic Generation Control Analysis With Governor Deadband Effects , 1979, IEEE Transactions on Power Apparatus and Systems.