Double-Antigen Lateral Flow Immunoassay for the Detection of Anti-HIV-1 and -2 Antibodies Using Upconverting Nanoparticle Reporters

Rapid diagnostic tests (RDTs) are often used for the detection of anti-human immunodeficiency virus (HIV) antibodies in remote locations in low- and middle-income countries (LMIC) with low or limited access to central laboratories. The typical format of an RDT is a lateral flow assay (LFA) with visual interpretation prone to subjectivity. This risk of misinterpretation can be overcome with luminescent upconverting nanoparticle reporters (UCNPs) measured with a miniaturized easy-to-use reader instrument. An LFA with UCNPs for anti-HIV-1/2 antibodies was developed and the assay performance was evaluated extensively with challenging patient sample panels. Sensitivity (n = 145) of the UCNP-LFA was 96.6% (95% CI: 92.1–98.8%) and specificity (n = 309) was 98.7% (95% CI: 96.7–99.7%). Another set of samples (n = 200) was used for a comparison between the UCNP-LFA and a conventional visual RDT. In this comparison, the sensitivities for HIV-1 were 96.4% (95% CI: 89.8–99.3%) and 97.6% (95% CI: 91.6–99.7%), for the UCNP-LFA and conventional RDT, respectively. The specificity was 100% (95% CI: 96.4–100%) for both assays. The developed UCNP-LFA demonstrates the applicability of UCNPs for the detection of anti-HIV antibodies. The signal measurement is done by a reader instrument, which may facilitate automated result interpretation, archiving and transfer of data from de-centralized locations.

[1]  Array-in-well platform-based multiplex assay for the simultaneous detection of anti-HIV- and treponemal-antibodies, and Hepatitis B surface antigen. , 2016, Journal of immunological methods.

[2]  Ralph-Sydney Mboumba Bouassa,et al.  Acceptability and Usability Evaluation of Finger-Stick Whole Blood HIV Self-Test as An HIV Screening Tool Adapted to The General Public in The Central African Republic , 2017, The open AIDS journal.

[3]  P. Chun Colloidal Gold and Other Labels for Lateral Flow Immunoassays , 2009 .

[4]  Adele M Wilson,et al.  Comparison of conventional lateral-flow assays and a new fluorescent immunoassay to detect influenza viruses. , 2013, Journal of virological methods.

[5]  T. Soukka,et al.  Upconverting Phosphor Labels for Bioanalytical Assays , 2013 .

[6]  Alexandr E Urusov,et al.  Towards Lateral Flow Quantitative Assays: Detection Approaches , 2019, Biosensors.

[7]  Lei Zhou,et al.  Rapid detection of severe fever with thrombocytopenia syndrome virus (SFTSV) total antibodies by up-converting phosphor technology-based lateral-flow assay. , 2019, Luminescence : the journal of biological and chemical luminescence.

[8]  T. Soukka,et al.  A highly sensitive and specific time resolved fluorometric bridge assay for antibodies to HIV-1 and -2. , 2011, Journal of virological methods.

[9]  K. Pettersson,et al.  Upconverting nanoparticle reporter–based highly sensitive rapid lateral flow immunoassay for hepatitis B virus surface antigen , 2020, Analytical and Bioanalytical Chemistry.

[10]  Helmut Schäfer,et al.  Upconverting nanoparticles. , 2011, Angewandte Chemie.

[11]  Mingyuan Gao,et al.  Upconversion luminescence nanoparticles-based lateral flow immunochromatographic assay for cephalexin detection , 2014 .

[12]  T. Soukka,et al.  Simultaneous detection of Human Immunodeficiency Virus 1 and Hepatitis B virus infections using a dual-label time-resolved fluorometric assay , 2010, Journal of nanobiotechnology.

[13]  H. Ayles,et al.  Ability to understand and correctly follow HIV self‐test kit instructions for use: applying the cognitive interview technique in Malawi and Zambia , 2019, Journal of the International AIDS Society.

[14]  K. Pettersson,et al.  All-in-one dry-reagent time-resolved immunofluorometric assay for the rapid detection of HIV-1 and -2 infections. , 2015, Journal of virological methods.

[15]  K. Pettersson,et al.  Ultrasensitive and Robust Point-of-Care Immunoassay for the Detection of Plasmodium falciparum Malaria. , 2020, Analytical chemistry.

[16]  S. Tonen-Wolyec,et al.  Insufficient education is a key factor of incorrect interpretation of HIV self-test results by female sex workers in Democratic Republic of the Congo , 2019, Medicine.

[17]  Dengfeng Gao,et al.  Household Fluorescent Lateral Flow Strip Platform for Sensitive and Quantitative Prognosis of Heart Failure Using Dual-Color Upconversion Nanoparticles. , 2017, ACS nano.

[18]  H. Tanke,et al.  Up-Converting Phosphor Technology-Based Lateral Flow Assay for Detection of Schistosoma Circulating Anodic Antigen in Serum , 2007, Journal of Clinical Microbiology.

[19]  Tero Soukka,et al.  Performance of fluorescent europium(III) nanoparticles and colloidal gold reporters in lateral flow bioaffinity assay. , 2012, Analytical biochemistry.

[20]  Katrien Fransen,et al.  Laboratory evaluation of four HIV/syphilis rapid diagnostic tests , 2019, BMC Infectious Diseases.

[21]  Lei Zhou,et al.  Development and Evaluation of Up-Converting Phosphor Technology-Based Lateral Flow Assay for Quantitative Detection of NT-proBNP in Blood , 2017, PloS one.

[22]  N. Ford,et al.  Reliability of HIV rapid diagnostic tests for self-testing compared with testing by health-care workers: a systematic review and meta-analysis , 2018, The lancet. HIV.

[23]  R. O'Kennedy,et al.  Strategies for overcoming challenges for decentralised diagnostics in resource-limited and catastrophe settings , 2017, Expert review of molecular diagnostics.

[24]  S. Tonen-Wolyec,et al.  Evaluation of the practicability and virological performance of finger-stick whole-blood HIV self-testing in French-speaking sub-Saharan Africa , 2018, PloS one.

[25]  W. Bishai,et al.  Diagnostic point-of-care tests in resource-limited settings. , 2014, The Lancet. Infectious diseases.

[26]  H. Tanke,et al.  Lateral flow assay for simultaneous detection of cellular- and humoral immune responses. , 2011, Clinical biochemistry.

[27]  Aydogan Ozcan,et al.  Emerging Technologies for Next-Generation Point-of-Care Testing. , 2015, Trends in biotechnology.

[28]  T. Bärnighausen,et al.  Female Sex Workers Often Incorrectly Interpret HIV Self-Test Results in Uganda , 2018, Journal of Acquired Immune Deficiency Syndromes.

[29]  Tianxing Ji,et al.  Point of care upconversion nanoparticles-based lateral flow assay quantifying myoglobin in clinical human blood samples , 2019, Sensors and Actuators B: Chemical.

[30]  Helen H. Lee,et al.  Rapid tests for detection of viral markers in blood transfusion , 2005, Expert review of molecular diagnostics.

[31]  J. Levy Pathogenesis of human immunodeficiency virus infection , 1989, Microbiological reviews.

[32]  Kobra Omidfar,et al.  New analytical applications of gold nanoparticles as label in antibody based sensors. , 2013, Biosensors & bioelectronics.