Three-dimensional registration of synchrotron radiation-based micro-computed tomography images with advanced laboratory micro-computed tomography data from murine kidney casts

Malfunction of oxygen regulation in kidney and liver may lead to the pathogenesis of chronic diseases. The underlying mechanisms are poorly understood. In kidney, it is hypothesized that renal gas shunting from arteries to veins eliminates excess oxygen. Such shunting is highly dependent on the structure of the renal vascular network. The vascular tree has so far not been quantified under maintenance of its connectivity as three-dimensional imaging of the vessel tree down to the smallest capillaries, which in mouse model are smaller than 5 μm in diameter, is a challenging task. An established protocol uses corrosion casts and applies synchrotron radiation-based micro-computed tomography (SRμCT), which provides the desired spatial resolution with the necessary contrast. However, SRμCT is expensive and beamtime access is limited. We show here that measurements with a phoenix nanotomrm (General Electric, Wunstorf, Germany) can provide comparable results to those obtained with SRμCT, except for regions with small vessel structures, where the signal-to-noise level was significantly reduced. For this purpose the nanotom®m measurement was compared with its corresponding measurement acquired at the beamline P05 at PETRA III at DESY, Hamburg, Germany.

[1]  Philipp Schneider,et al.  Hierarchical microimaging for multiscale analysis of large vascular networks , 2006, NeuroImage.

[2]  Adrian Stefan Andronache Multi-modal non-rigid registration of volumetric medical images , 2006 .

[3]  Felix Beckmann,et al.  Comparison between x-ray tube-based and synchrotron radiation-based μCT , 2008, Optical Engineering + Applications.

[4]  Bert Müller,et al.  Visualization of tumor vessels using synchrotron radiation- based micro computed tomography , 2009 .

[5]  Timm Weitkamp,et al.  Global and local hard X-ray tomography of a centimeter-size tumor vessel tree. , 2012, Journal of synchrotron radiation.

[6]  Markus Rudin,et al.  Comparing the micro-vascular structure of cancerous and healthy tissues , 2012, Optics & Photonics - Optical Engineering + Applications.

[7]  Nicolas P Smith,et al.  Structural morphology of renal vasculature. , 2006, American journal of physiology. Heart and circulatory physiology.

[8]  Bertram L Kasiske,et al.  Cardiovascular disease in chronic kidney disease. A clinical update from Kidney Disease: Improving Global Outcomes (KDIGO). , 2011, Kidney international.

[9]  S. Wilkins,et al.  Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object , 2002, Journal of microscopy.

[10]  Timm Weitkamp,et al.  Three-dimensional quantification of capillary networks in healthy and cancerous tissues of two mice. , 2012, Microvascular research.

[11]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[12]  William Bowman,et al.  IV. On the structure and use of the Malpighian bodies of the kidney, with observations on the circulation through that gland , 1842, Philosophical Transactions of the Royal Society of London.

[13]  Thomas Krucker,et al.  New polyurethane‐based material for vascular corrosion casting with improved physical and imaging characteristics , 2006, Microscopy research and technique.

[14]  Kai-Uwe Eckardt,et al.  Role of hypoxia in the pathogenesis of renal disease. , 2005, Kidney international. Supplement.

[15]  Luigi Mariani,et al.  Three-dimensional imaging of human hippocampal tissue using synchrotron radiation- and grating-based micro computed tomography , 2014, Optics & Photonics - Optical Engineering + Applications.

[16]  Elin Pauwels,et al.  High-Resolution Imaging of Kidney Vascular Corrosion Casts with Nano-CT , 2010, Microscopy and Microanalysis.

[17]  M. Brezis,et al.  Hypoxia of the renal medulla--its implications for disease. , 1995, The New England journal of medicine.

[18]  Franz Pfeiffer,et al.  Asymmetric rotational axis reconstruction of grating-based x-ray phase contrast tomography of the human cerebellum , 2012, Optics & Photonics - Optical Engineering + Applications.

[19]  E L Ritman,et al.  Three-dimensional microcomputed tomography of renal vasculature in rats. , 1998, Hypertension.

[20]  Timm Weitkamp,et al.  Morphology of bony tissues and implants uncovered by high-resolution tomographic imaging , 2007 .

[21]  Josef Coresh,et al.  Chronic kidney disease , 2012, The Lancet.

[22]  Thomas Dose,et al.  Latest developments in microtomography and nanotomography at PETRA III , 2010, Powder Diffraction.