Electrical Characterization of 3D Au Microelectrodes for Use in Retinal Prostheses

In order to provide high-quality visual information to patients who have implanted retinal prosthetic devices, the number of microelectrodes should be large. As the number of microelectrodes is increased, the dimensions of each microelectrode must be decreased, which in turn results in an increased microelectrode interface impedance and decreased injection current dynamic range. In order to improve the trade-off envelope between the number of microelectrodes and the current injection characteristics, a 3D microelectrode structure can be used as an alternative. In this paper, the electrical characteristics of 2D and 3D Au microelectrodes were investigated. In order to examine the effects of the structural difference, 2D and 3D Au microelectrodes with different base areas but similar effective surface areas were fabricated and evaluated. Interface impedances were measured and similar dynamic ranges were obtained for both 2D and 3D Au microelectrodes. These results indicate that more electrodes can be implemented in the same area if 3D designs are used. Furthermore, the 3D Au microelectrodes showed substantially enhanced electrical durability characteristics against over-injected stimulation currents, withstanding electrical currents that are much larger than the limit measured for 2D microelectrodes of similar area. This enhanced electrical durability property of 3D Au microelectrodes is a new finding in microelectrode research, and makes 3D microelectrodes very desirable devices.

[1]  S. Park,et al.  Electrical characteristics of 2D and 3D microelectrodes for high-resolution retinal prostheses , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[2]  B. Jones,et al.  Retinal remodeling during retinal degeneration. , 2005, Experimental eye research.

[3]  Samip P. Shah,et al.  Electrical properties of retinal–electrode interface , 2007, Journal of neural engineering.

[4]  Marian Popescu,et al.  Design, Fabrication and Characterization of a Low-Impedance 3D Electrode Array System for Neuro-Electrophysiology , 2012, Sensors.

[5]  Benjamin Rappaz,et al.  Simulation of artificial vision, III: do the spatial or temporal characteristics of stimulus pixelization really matter? , 2005, Investigative ophthalmology & visual science.

[6]  P. Gillet,et al.  Cell and tissue engineering and clinical applications: an overview. , 2006, Bio-medical materials and engineering.

[7]  Tetsu Tanaka,et al.  Comparison of electrode materials for the use of retinal prosthesis. , 2011, Bio-medical materials and engineering.

[8]  J. L. Stone,et al.  Morphometric analysis of macular photoreceptors and ganglion cells in retinas with retinitis pigmentosa. , 1992, Archives of ophthalmology.

[9]  D. Cho,et al.  Mechanical and electrical evaluation for the long-term stability of implanted 3D retinal microelectrode , 2011, 2011 16th International Solid-State Sensors, Actuators and Microsystems Conference.

[10]  Dong-Il Cho,et al.  A Novel In Vitro Sensing Configuration for Retinal Physiology Analysis of a Sub-Retinal Prosthesis , 2012, Sensors.

[11]  E. Zrenner,et al.  Can subretinal microphotodiodes successfully replace degenerated photoreceptors? , 1999, Vision Research.

[12]  S. Cogan Neural stimulation and recording electrodes. , 2008, Annual review of biomedical engineering.

[13]  So Hyun Bae,et al.  Arrowhead-Shaped Microelectrodes Fabricated on a Flexible Substrate for Enhancing the Spherical Conformity of Retinal Prostheses , 2011, Journal of Microelectromechanical Systems.

[14]  Dong-il Dan Cho,et al.  Fabrication of pyramid shaped three-dimensional 8 × 8 electrodes for artificial retina , 2006 .

[15]  Alfred Stett,et al.  Subretinal electronic chips allow blind patients to read letters and combine them to words , 2010, Proceedings of the Royal Society B: Biological Sciences.

[16]  Dong-Il Cho,et al.  Multi-channel stimulator IC using a channel sharing method for retinal prostheses. , 2013, Journal of biomedical nanotechnology.

[17]  Linh Hoang,et al.  An Integrated 256-Channel Epiretinal Prosthesis , 2010, IEEE Journal of Solid-State Circuits.

[18]  D Hickingbotham,et al.  Bipolar surface electrical stimulation of the vertebrate retina. , 1994, Archives of ophthalmology.